Literature DB >> 20512860

Phase-contrast velocimetry with simultaneous fat/water separation.

Kevin M Johnson1, Oliver Wieben, Alexey A Samsonov.   

Abstract

Phase-contrast MRI can provide high-resolution angiographic velocity images, especially in conjunction with non-Cartesian k-space sampling. However, acquisitions can be sensitive to errors from artifacts from main magnetic field inhomogeneities and chemical shift from fat. Particularly in body imaging, fat content can cause degraded image quality, create errors in the velocity measurements, and prevent the use of self-calibrated amplitude of static field heterogeneity corrections. To reduce the influence of fat and facilitate self-calibrated amplitude of static field heterogeneity corrections, a combination of chemical shift imaging with phase-contrast velocimetry with nonlinear least-squares estimation of velocity, fat, and water signals is proposed. A chemical shift and first-moment symmetric dual-echo sequence is proposed to minimize the scan time penalty, and initial investigations are performed in phantoms and volunteers that show reduced influence from fat in velocity images. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20512860      PMCID: PMC3057179          DOI: 10.1002/mrm.22355

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imaging.

Authors:  J M Tyszka; D H Laidlaw; J W Asa; J M Silverman
Journal:  J Magn Reson Imaging       Date:  2000-08       Impact factor: 4.813

2.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Time-optimal multidimensional gradient waveform design for rapid imaging.

Authors:  Brian A Hargreaves; Dwight G Nishimura; Steven M Conolly
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast.

Authors:  Jong B Park; Eric W Olcott; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

5.  MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions.

Authors:  Panorea Papathanasopoulou; Shunzhi Zhao; Uwe Köhler; Malcolm B Robertson; Quan Long; Peter Hoskins; X Yun Xu; Ian Marshall
Journal:  J Magn Reson Imaging       Date:  2003-02       Impact factor: 4.813

6.  Three-dimensional phase contrast velocity mapping acquisition improves wall shear stress estimation in vivo.

Authors:  Sheng Ping Wu; Steffen Ringgaard; Erik Morre Pedersen
Journal:  Magn Reson Imaging       Date:  2004-04       Impact factor: 2.546

7.  Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects.

Authors:  Hugo G Bogren; Michael H Buonocore; Richard J Valente
Journal:  J Magn Reson Imaging       Date:  2004-04       Impact factor: 4.813

8.  Noise correlations in data simultaneously acquired from multiple surface coil arrays.

Authors:  C E Hayes; P B Roemer
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

9.  Images in cardiovascular medicine. Time-resolved 3-dimensional magnetic resonance velocity mapping at 3 T reveals drastic changes in flow patterns in a partially thrombosed aortic arch.

Authors:  Alex Frydrychowicz; Ernst Weigang; Andreas Harloff; Friedhelm Beyersdorf; Jürgen Hennig; Mathias Langer; Michael Markl
Journal:  Circulation       Date:  2006-03-21       Impact factor: 29.690

10.  Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry.

Authors:  P Beerbaum; H Körperich; P Barth; H Esdorn; J Gieseke; H Meyer
Journal:  Circulation       Date:  2001-05-22       Impact factor: 29.690

View more
  4 in total

1.  Surgical planning for living donor liver transplant using 4D flow MRI, computational fluid dynamics and in vitro experiments.

Authors:  David R Rutkowski; Scott B Reeder; Luis A Fernandez; Alejandro Roldán-Alzate
Journal:  Comput Methods Biomech Biomed Eng Imaging Vis       Date:  2017-01-18

2.  Chemical shift-induced phase errors in phase-contrast MRI.

Authors:  Matthew J Middione; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2012-04-06       Impact factor: 4.668

3.  General phase regularized reconstruction using phase cycling.

Authors:  Frank Ong; Joseph Y Cheng; Michael Lustig
Journal:  Magn Reson Med       Date:  2017-11-21       Impact factor: 4.668

4.  Flow-induced signal misallocation artifacts in two-point fat-water chemical shift MRI.

Authors:  Mahdi Salmani Rahimi; James H Holmes; Kang Wang; Scott B Reeder; Frank R Korosec
Journal:  Magn Reson Med       Date:  2014-06-09       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.