Literature DB >> 11241708

Automatic scan prescription for brain MRI.

L Itti1, L Chang, T Ernst.   

Abstract

Diagnostic brain MRI scans are usually performed by trained medical technologists who manually prescribe the position and orientation of a scanning volume. In this study, a fully automatic computer algorithm is described which compensates for variable patient positioning and acquires brain MRI scans in a predefined reference orientation. The method involves acquiring a rapid water-only pilot scan, segmenting the brain surface, and matching it to a reference surface. The inverse matching transformation is then used to adapt a geometric description of the desired scanning volume, defined relative to the reference surface, to the current patient. Both pilot scan and processing are performed within 30 sec. The method was tested in 25 subjects, and consistently recovered orientation differences between the reference and each subject to within +/-5 degrees. Compared to manual prescription, automatic scan prescription promises many potential benefits, including reduced scan times, reproducible scan orientations along anatomically preferable orientations, and better reproducibility for longitudinal studies. Magn Reson Med 45:486-494, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11241708     DOI: 10.1002/1522-2594(200103)45:3<486::aid-mrm1064>3.0.co;2-#

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  AutoVOI: real-time automatic prescription of volume-of-interest for single voxel spectroscopy.

Authors:  Young Woo Park; Dinesh K Deelchand; James M Joers; Brian Hanna; Adam Berrington; Joseph S Gillen; Kejal Kantarci; Brian J Soher; Peter B Barker; HyunWook Park; Gülin Öz; Christophe Lenglet
Journal:  Magn Reson Med       Date:  2018-04-06       Impact factor: 4.668

2.  Fast prospective registration of in vivo MR images of trabecular bone microstructure in longitudinal studies.

Authors:  Chamith S Rajapakse; Jeremy F Magland; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

3.  Automatic voxel positioning for MRS at 7 T.

Authors:  Weiqiang Dou; Oliver Speck; Thomas Benner; Jörn Kaufmann; Meng Li; Kai Zhong; Martin Walter
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

4.  Reproducibility of scan prescription in follow-up brain MRI: manual versus automatic determination.

Authors:  Shinya Kojima; Masami Hirata; Hiroyuki Shinohara; Eiko Ueno
Journal:  Radiol Phys Technol       Date:  2013-04-11

5.  The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study.

Authors:  Esben Thade Petersen; Kim Mouridsen; Xavier Golay
Journal:  Neuroimage       Date:  2009-08-04       Impact factor: 6.556

6.  Prospective image registration for automated scan prescription of follow-up knee images in quantitative studies.

Authors:  Janet Goldenstein; Joseph Schooler; Jason C Crane; Eugene Ozhinsky; Jean-Baptiste Pialat; Julio Carballido-Gamio; Sharmila Majumdar
Journal:  Magn Reson Imaging       Date:  2011-05-05       Impact factor: 2.546

7.  Automated prescription of oblique brain 3D magnetic resonance spectroscopic imaging.

Authors:  Eugene Ozhinsky; Daniel B Vigneron; Susan M Chang; Sarah J Nelson
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

8.  Clinical brain MR imaging prescriptions in Talairach space: technologist- and computer-driven methods.

Authors:  Kenneth L Weiss; Hai Pan; Judd Storrs; William Strub; Jane L Weiss; Li Jia; O Petter Eldevik
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

9.  Rapid head-pose detection for automated slice prescription of fetal-brain MRI.

Authors:  Malte Hoffmann; Esra Abaci Turk; Borjan Gagoski; Leah Morgan; Paul Wighton; M Dylan Tisdall; Martin Reuter; Elfar Adalsteinsson; P Ellen Grant; Lawrence L Wald; André J W van der Kouwe
Journal:  Int J Imaging Syst Technol       Date:  2021-03-01       Impact factor: 2.000

10.  Automated Voxel Placement: A Linux-based Suite of Tools for Accurate and Reliable Single Voxel Coregistration.

Authors:  Eric A Woodcock; Muzamil Arshad; Dalal Khatib; Jeffrey A Stanley
Journal:  J Neuroimaging Psychiatry Neurol       Date:  2018-02-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.