Literature DB >> 11202450

Choice of collimator for cardiac SPET when resolution compensation is included in iterative reconstruction.

Y H Lau1, B F Hutton, F J Beekman.   

Abstract

In clinical cardiac single-photon emission tomography (SPET) studies, collimators of different spatial resolution and geometric efficiency are available for imaging. In selecting the appropriate collimator for clinical use, there is a trade-off between spatial resolution, which can limit the contrast of the reconstructed image, and detection efficiency, which determines the noise in the image. Our objective was to assess which collimator is best suited for cardiac SPET when reconstruction is performed with and without compensation for distance-dependent resolution (CDR). The dynamic MCAT thorax phantom was used to simulate 180 degree technetium-99m cardiac data, acquired using either a general-purpose (GP) or high-resolution (HR) collimator. For GP and HR, the resolution at 15 cm was 11.5 mm and 9.5 mm respectively, and the corresponding relative efficiency was 1.0 and 0.52 respectively. Distance-dependent resolution, attenuation and noise were included in the projection data; scatter was not included. Ordered subsets expectation maximisation reconstruction (subset size 4) was performed with and without CDR. Results were evaluated by comparing the myocardial recovery coefficient and contrast between myocardium and ventricle relative to the original phantom, each plotted for different noise levels corresponding to increasing iteration number. The study demonstrated that, without CDR, HR gave the best results. However, for any given noise level with CDR, GP gave superior recovery and contrast. These findings were confirmed in a physical phantom study. Results suggest that improved reconstruction can be achieved using a GP collimator in combination with resolution compensation.

Entities:  

Mesh:

Year:  2001        PMID: 11202450     DOI: 10.1007/s002590000387

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Myocardial perfusion SPECT just keeps getting better and better.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2016-02-16       Impact factor: 5.952

4.  Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantification.

Authors:  Sarah J McQuaid; Sudeepti Southekal; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2011-11-07       Impact factor: 3.609

5.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

6.  Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.

Authors:  Michael Ghaly; Yong Du; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

7.  High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.

Authors:  Bin Zhang; Gengsheng L Zeng
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-05-10

Review 8.  Advances in nuclear cardiac instrumentation with a view towards reduced radiation exposure.

Authors:  Piotr J Slomka; Damini Dey; W Lane Duvall; Milena J Henzlova; Daniel S Berman; Guido Germano
Journal:  Curr Cardiol Rep       Date:  2012-04       Impact factor: 2.931

9.  Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

Authors:  Ian S Armstrong; Kimberley J Saint; Christine M Tonge; Parthiban Arumugam
Journal:  J Nucl Cardiol       Date:  2016-01-25       Impact factor: 5.952

10.  Reduction of collimator correction artefacts with bayesian reconstruction in spect.

Authors:  Tuija Kangasmaa; Antti Sohlberg; Jyrki T Kuikka
Journal:  Int J Mol Imaging       Date:  2010-12-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.