Plaque volume determined by common linear 3-D IVUS analysis systems will show under- or overestimation in curved vessel segments because these systems approximate the true 3-D transducer pull-back trajectory by a straight line. We developed a mathematical model that showed that the error is primarily dependent on the curvature of the pull-back trajectory and not on vessel tortuosity. Furthermore, we measured this error in vivo in the coronary arteries of 15 patients, comparing the plaque volume using a true 3-D reconstruction method with that of the linear approach. The in vivo plaque volume error ranged from 2.3% to -1.2% for 15 coronary segments with lengths ranging from 38.8 to 89.1 mm (62.2 +/- 13 mm). The volume error introduced by linear 3-D IVUS analysis systems is dependent on the curvature of the pull-back trajectory. The error measured in vivo was small and inversely related to segment length.

Entities:  

Mesh:

Year:  2000        PMID: 11179614     DOI: 10.1016/s0301-5629(00)00295-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Volumetric intravascular ultrasound measurements in coronary arteries.

Authors:  Clemens von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

2.  Advanced contour detection for three-dimensional intracoronary ultrasound: a validation--in vitro and in vivo.

Authors:  Gerhard Koning; Jouke Dijkstra; Clemens von Birgelen; Joan C Tuinenburg; Jean Brunette; Jean-Claude Tardif; Pranobe W Oemrawsingh; Christian Sieling; Sören Melsa; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2002-08       Impact factor: 2.357

3.  Intra- and interobserver variability in detection and assessment of calcified and noncalcified coronary artery plaques using 64-slice computed tomography: variability in coronary plaque measurement using MSCT.

Authors:  Hans Hoffmann; Katja Frieler; Bernd Hamm; Marc Dewey
Journal:  Int J Cardiovasc Imaging       Date:  2008-06-28       Impact factor: 2.357

4.  Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus.

Authors:  Nobuaki Suzuki; Hitesh Nanda; Dominick J Angiolillo; Hiran Bezerra; Manel Sabaté; Pilar Jiménez-Quevedo; Fernando Alfonso; Carlos Macaya; Theodore A Bass; Olusegun J Ilegbusi; Marco A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2007-10-31       Impact factor: 2.357

Review 5.  The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review.

Authors:  Yakup Kilic; Hannah Safi; Retesh Bajaj; Patrick W Serruys; Pieter Kitslaar; Anantharaman Ramasamy; Vincenzo Tufaro; Yoshinobu Onuma; Anthony Mathur; Ryo Torii; Andreas Baumbach; Christos V Bourantas
Journal:  Front Cardiovasc Med       Date:  2020-03-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.