Literature DB >> 11168264

Mechanical complications of dental implants.

M S Schwarz1.   

Abstract

Adverse occlusal forces can result in mechanical complications of implant components. While unacceptably high incidences of mechanical failures have been reported for the two-stage external hex screw-type implant systems, the standard-diameter ITI solid-screw implant does not seem to be vulnerable to these problems. The 8 degrees Morse taper has eliminated abutment screw loosening and fracture. The incidence of prosthetic screw loosening has been minimized by the 45 degrees bevel on the implant shoulder and by the 1.5 mm vertical abutment walls. The design of the standard-diameter solid-screw ITI implant and the material used in its fabrication (cold worked type IV cp titanium) have eliminated fixture fracture. However, because there have been some reported instances of fractures involving reduced-diameter and hollow implants, these designs should be used with caution.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11168264     DOI: 10.1034/j.1600-0501.2000.011s1156.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  45 in total

Review 1.  Applications of microscale technologies for regenerative dentistry.

Authors:  S A Hacking; A Khademhosseini
Journal:  J Dent Res       Date:  2009-05       Impact factor: 6.116

2.  A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

Authors:  Parth Satwalekar; K Subash Chander; B Anantha Reddy; N Sandeep; N Sandeep; Tanushree Satwalekar
Journal:  J Int Oral Health       Date:  2013-10-26

Review 3.  Management of abutment screw loosening: review of literature and report of a case.

Authors:  Vinod Krishnan; C Tony Thomas; Ipe Sabu
Journal:  J Indian Prosthodont Soc       Date:  2013-10-25

4.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

5.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

6.  Implant fracture under dynamic fatigue loading: influence of embedded angle and depth of implant.

Authors:  Hiroaki Suzuki; Yoshiaki Hata; Fumihiko Watanabe
Journal:  Odontology       Date:  2015-12-23       Impact factor: 2.634

Review 7.  Regenerative Medicine Strategies in Biomedical Implants.

Authors:  Divya Rani Bijukumar; Clay McGeehan; Mathew T Mathew
Journal:  Curr Osteoporos Rep       Date:  2018-06       Impact factor: 5.096

8.  Sinking and fit of abutment of locking taper implant system.

Authors:  Seung-Jin Moon; Hee-Jung Kim; Mee-Kyoung Son; Chae-Heon Chung
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

Review 9.  Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review.

Authors:  Redouane Messous; Bruno Henriques; Hassan Bousbaa; Filipe S Silva; Wim Teughels; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

10.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.