Literature DB >> 11110309

Cut edges and surface characteristics produced by different microkeratomes.

F W Wilhelm1, T Giessmann, R Hanschke, G I Duncker, L H Wilhelm.   

Abstract

PURPOSE: To determine the cutting characteristics of seven different microkeratomes and to compare the cut edges and surface characteristics of the corneas with respect to different keratome parameters, ie, blade oscillation frequencies and keratome speed.
METHODS: Lamellar keratectomies were performed using each microkeratome on eight freshly enucleated porcine corneas. The freshly cut corneal bed was then examined using scanning electron microscopy. A scoring system was used to evaluate the serration of the cut edge and the regularity of the corneal wound bed.
RESULTS: Serrated cut edges were produced by the Microtech microkeratome, the Automatic Corneal Shaper, the Draeger rotor keratome, and the Schwind microkeratome. The other tested cutting devices generally yielded a smooth cut edge. Smooth and regular wound surfaces were obtained with the Schwind microkeratome, the Automatic Corneal Shaper, the Microtech microkeratome, and the MKM set. The specimens cut with the Schwind microkeratome showed particularly regular surface characteristics.
CONCLUSION: The relationship between keratome propulsion speed, blade oscillation frequency, and blade material appears crucial for the quality of the microkeratome cut. Our results favor a low advancement/oscillation ratio among automated microkeratomes.

Entities:  

Mesh:

Year:  2000        PMID: 11110309     DOI: 10.3928/1081-597X-20001101-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  9 in total

1.  [Scanning electron microscopic characteristics of lamellar keratotomies using the Femtec femtosecond laser and the Zyoptix XP microkeratome. A comparison of quality].

Authors:  J Heichel; T Hammer; R Sietmann; G I W Duncker; F Wilhelm
Journal:  Ophthalmologe       Date:  2010-04       Impact factor: 1.059

2.  Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters.

Authors:  Kathleen S Kunert; Marcus Blum; Gernot I W Duncker; Rabea Sietmann; Jens Heichel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-01-15       Impact factor: 3.117

3.  Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty.

Authors:  Chenxing Zhang; Matthew Bald; Maolong Tang; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2015-03-04       Impact factor: 3.351

4.  Impact of head advance and oscillation rate on the flap parameter: a comparison of two microkeratomes.

Authors:  Stefanie Hoffmann; Frank Krummenauer; Mana Tehrani; H Burkhard Dick
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-01-28       Impact factor: 3.117

5.  Automated superficial lamellar keratectomy augmented by excimer laser masked PTK in the management of severe superficial corneal opacities.

Authors:  J L Alio; J Javaloy; J Merayo; A Galal
Journal:  Br J Ophthalmol       Date:  2004-10       Impact factor: 4.638

6.  Analysis of corneal stromal roughness after iFS 150 kHz and LenSx femtosecond LASIK flap creation in porcine eyes.

Authors:  Juan Gros-Otero; Samira Ketabi; Rafael Cañones-Zafra; Montserrat Garcia-Gonzalez; Alberto Parafita-Fernandez; Cesar Villa-Collar; Santiago Casado; Miguel Teus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-24       Impact factor: 3.117

7.  A pilot study: lenticule quality of hyperopic small incision lenticule extraction (SMILE) in rabbits.

Authors:  Yu Zhao; Feng Zhao; Tian Han; Jing Zhao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2020-04-19       Impact factor: 2.209

8.  Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis.

Authors:  Jens Heichel; Frank Wilhelm; Kathleen S Kunert; Rabea Schlueter; Ute Stuhltraeger; Thomas Hammer
Journal:  Clin Ophthalmol       Date:  2013-12-17

9.  Optical Vortex Beam for Gentle and Ultraprecise Intrastromal Corneal Dissection in Refractive Surgery.

Authors:  Sebastian Freidank; Alfred Vogel; Norbert Linz
Journal:  Transl Vis Sci Technol       Date:  2020-09-23       Impact factor: 3.283

  9 in total