Literature DB >> 11044013

Interpretation of Emergency Department radiographs: a comparison of emergency medicine physicians with radiologists, residents with faculty, and film with digital display.

J Eng1, W K Mysko, G E Weller, R Renard, J N Gitlin, D A Bluemke, D Magid, G D Kelen, W W Scott.   

Abstract

OBJECTIVE: We determined the relative value of teleradiology and radiology resident coverage of the emergency department by measuring and comparing the effects of physician specialty, training level, and image display method on accuracy of radiograph interpretation.
MATERIALS AND METHODS: A sample of four faculty emergency medicine physicians, four emergency medicine residents, four faculty radiologists, and four radiology residents participated in our study. Each physician interpreted 120 radiographs, approximately half containing a clinically important index finding. Radiographs were interpreted using the original films and high-resolution digital monitors. Accuracy of radiograph interpretation was measured as the area under the physicians' receiver operating characteristic (ROC) curves.
RESULTS: The area under the ROC curve was 0.15 (95% confidence interval [CI], 0.10-0.20) greater for radiologists than for emergency medicine physicians, 0.07 (95% CI, 0.02-0.12) greater for faculty than for residents, and 0.07 (95% CI, 0.02-0.12) greater for films than for video monitors. Using these results, we estimated that teleradiology coverage by faculty radiologists would add 0.09 (95% CI, 0.03-0.15) to the area under the ROC curve for radiograph interpretation by emergency medicine faculty alone, and radiology resident coverage would add 0.08 (95% CI, 0.02-0.14) to this area.
CONCLUSION: We observed significant differences between the interpretation of radiographs on film and on digital monitors. However, we observed differences of equal or greater magnitude associated with the training level and physician specialty of each observer. In evaluating teleradiology services, observer characteristics must be considered in addition to the quality of image display.

Mesh:

Year:  2000        PMID: 11044013     DOI: 10.2214/ajr.175.5.1751233

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

1.  Economic impact of real-time teleradiology in thoracic CT examinations.

Authors:  Akihiro Takada; Toshiyuki Kasahara; Yasutomi Kinosada; Minoru Hosoba; Tsunehiko Nishimura
Journal:  Eur Radiol       Date:  2002-10-19       Impact factor: 5.315

2.  Quality control in neuroradiology: discrepancies in image interpretation among academic neuroradiologists.

Authors:  L S Babiarz; D M Yousem
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  The gold standard: PACS alchemy and the gold standard.

Authors:  Kenneth Burgess; Thomas L Slovis
Journal:  Pediatr Radiol       Date:  2004-10-23

4.  A comparative study of conventional mammography film interpretations with soft copy readings of the same examinations.

Authors:  Joseph N Gitlin; Anand K Narayan; Chad A Mitchell; Ali M Akmal; David J Eisner; Lindsy M Peterson; Daisy Nie; Tyler R McClintock
Journal:  J Digit Imaging       Date:  2007-03       Impact factor: 4.056

5.  Quality outcomes of reinterpretation of brain CT imaging studies by subspecialty experts in neuroradiology.

Authors:  Maryum J Jordan; Johnson B Lightfoote; John E Jordan
Journal:  J Natl Med Assoc       Date:  2006-08       Impact factor: 1.798

6.  Plain abdominal radiographs: can we interpret them?

Authors:  C Beverly B Lim; Vivian Chen; Allon Barsam; Jeremy Berger; Richard A Harrison
Journal:  Ann R Coll Surg Engl       Date:  2006-01       Impact factor: 1.891

7.  Vertical or horizontal orientation of foot radiographs does not affect image interpretation.

Authors:  Nicholas Antonio Ferran; Luke Ball; Nicola Maffulli
Journal:  Muscles Ligaments Tendons J       Date:  2013-01-21

8.  Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study.

Authors:  Antonio J Salazar; Juan Camilo Camacho; Diego Andrés Aguirre
Journal:  Telemed J E Health       Date:  2011-04-01       Impact factor: 3.536

9.  Comparison between different cost devices for digital capture of X-ray films: an image characteristics detection approach.

Authors:  Antonio José Salazar; Juan Camilo Camacho; Diego Andrés Aguirre
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

10.  Identification and interpretation of maxillofacial plain radiographs by junior dental trainees.

Authors:  Oa Akadiri; Aa Olusanya; Se Udeabor; Ce Agi
Journal:  J West Afr Coll Surg       Date:  2012-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.