Literature DB >> 11025518

Gradient preemphasis calibration in diffusion-weighted echo-planar imaging.

N G Papadakis1, K M Martin, J D Pickard, L D Hall, T A Carpenter, C L Huang.   

Abstract

This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions. The efficiency of the technique was demonstrated not only by the reduction of eddy-current fields to a negligible level using full preemphasis compensation, but also by the fact that adjustment of the slow time-base alone sufficed for the practical elimination of image distortions in the DW-SE-EPI images and the subsequent diffusion tensor maps (in a phantom and a human brain). By seeking to eliminate directly the effect of eddy-current-induced phase shifts during the EPI data collection, the method is free of the complications and restrictions associated with other eddy-current correction techniques for DW-SE-EPI (such as acquisition of additional calibration scans, intense postprocessing, extensive pulse-sequence modifications), making their use redundant.

Entities:  

Mesh:

Year:  2000        PMID: 11025518     DOI: 10.1002/1522-2594(200010)44:4<616::aid-mrm16>3.0.co;2-t

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  Diffusion weighted magnetic resonance imaging and its recent trend-a survey.

Authors:  Geetha Soujanya Chilla; Cher Heng Tan; Chenjie Xu; Chueh Loo Poh
Journal:  Quant Imaging Med Surg       Date:  2015-06

Review 2.  Body MR Imaging: Artifacts, k-Space, and Solutions.

Authors:  Susie Y Huang; Ravi T Seethamraju; Pritesh Patel; Peter F Hahn; John E Kirsch; Alexander R Guimaraes
Journal:  Radiographics       Date:  2015-07-24       Impact factor: 5.333

3.  A multifunction digital receiver suitable for real-time frequency detection and compensation in fast magnetic resonance imaging.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2019-05       Impact factor: 1.523

4.  Parallel 2D FFT implementation on FPGA suitable for real-time MR image processing.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2018-09       Impact factor: 1.523

5.  Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence.

Authors:  Jinnan Wang; Vasily L Yarnykh; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

6.  High spatial resolution diffusion weighted imaging on clinical 3 T MRI scanners using multislab spiral acquisitions.

Authors:  Joseph L Holtrop; Bradley P Sutton
Journal:  J Med Imaging (Bellingham)       Date:  2016-04-12

7.  Quantification and compensation of eddy-current-induced magnetic-field gradients.

Authors:  William M Spees; Niels Buhl; Peng Sun; Joseph J H Ackerman; Jeffrey J Neil; Joel R Garbow
Journal:  J Magn Reson       Date:  2011-06-25       Impact factor: 2.229

Review 8.  Diffusion tensor imaging and beyond.

Authors:  Jacques-Donald Tournier; Susumu Mori; Alexander Leemans
Journal:  Magn Reson Med       Date:  2011-04-05       Impact factor: 4.668

9.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

10.  Improving the correction of eddy current-induced distortion in diffusion-weighted images by excluding signals from the cerebral spinal fluid.

Authors:  Wei Liu; Xiaozheng Liu; Guang Yang; Zhenyu Zhou; Yongdi Zhou; Gengying Li; Marc Dubin; Ravi Bansal; Bradley S Peterson; Dongrong Xu
Journal:  Comput Med Imaging Graph       Date:  2012-07-24       Impact factor: 4.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.