Cataract extraction with multifocal intraocular lens implantation: clinical, functional, and quality-of-life outcomes. Multicenter clinical trial in Germany and Austria.

J Javitt1, H P Brauweiler, K W Jacobi, U Klemen, S Kohnen, C D Quentin, C Teping, T Pham, M C Knorz, D Pöetzsch.   

Abstract

PURPOSE: To compare bilateral implantation of a multifocal intraocular lens (IOL) versus a monofocal lens with respect to visual function, patient satisfaction, and quality of life.
SETTING: Seven clinical sites in Germany and 1 site in Austria.
METHODS: A prospective randomized masked clinical trial included 124 randomly assigned bilateral pseudophakic individuals, 64 of whom had bilateral implantation of an Array(R) foldable multifocal IOL (model SA-40N, Allergan) and 60 of whom had bilateral implantation of an AMO(R)PhacoFlex II(R) silicone monofocal IOL (model SI-40NB). Clinical data included binocular uncorrected and corrected distance and near visual acuities, complications, adverse events, and reports of halos and glare. Quality-of-life data were collected on 3 occasions using the modified Cataract TyPE Specification instrument. The functional status of the 2 groups was compared from baseline to final postoperative interview.
RESULTS: Three months after surgery, a higher proportion in the Array group achieved a Jaeger value of J3 (20/40 Snellen) or better uncorrected binocular near visual acuity and 0.5 (20/40) or better distance-corrected binocular near visual acuity than in the monofocal groups (97% versus 68% and 95% versus 59%, respectively; P <.001). A higher proportion in the multifocal group achieved both 0.5 (20/40) and J3 or better uncorrected binocular distance and near visual acuities (97% versus 66%; P <.001). Those in the Array group were more likely than those in the monofocal group to never wear glasses overall (41% versus 12%; P <.001). Multifocal patients rated their vision without glasses better overall, at near and at intermediate distances (P <.05), and demonstrated better visual function for near tasks and social activities.
CONCLUSIONS: Those who had bilateral implantation of the Array multifocal IOL obtained better uncorrected and distance-corrected near visual acuities and reported better overall vision, less limitation in visual function, and less spectacle dependency than patients with bilateral monofocal IOLs.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11020621     DOI: 10.1016/s0886-3350(00)00636-2

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  20 in total

Review 1.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

Review 3.  [Presbyopia correction using intraocular lenses].

Authors:  M P Holzer; T M Rabsilber; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

4.  [Influence of different multifocal intraocular lens concepts on retinal stray light parameters].

Authors:  A Ehmer; T M Rabsilber; A Mannsfeld; M J Sanchez; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-10       Impact factor: 1.059

5.  Measuring the impact of cataract surgery on generic and vision-specific quality of life.

Authors:  Erik J Groessl; Lin Liu; Marisa Sklar; Steven R Tally; Robert M Kaplan; Theodore G Ganiats
Journal:  Qual Life Res       Date:  2012-09-27       Impact factor: 4.147

Review 6.  Multifocal versus monofocal intraocular lenses after cataract extraction.

Authors:  Samantha R de Silva; Jennifer R Evans; Varo Kirthi; Mohammed Ziaei; Martin Leyland
Journal:  Cochrane Database Syst Rev       Date:  2016-12-12

7.  Cost effectiveness of foldable multifocal intraocular lenses compared to foldable monofocal intraocular lenses for cataract surgery.

Authors:  M G T Dolders; M D Nijkamp; R M M A Nuijts; B van den Borne; F Hendrikse; A Ament; W Groot
Journal:  Br J Ophthalmol       Date:  2004-09       Impact factor: 4.638

Review 8.  [Design and optical principles of multifocal lenses].

Authors:  G U Auffarth; T M Rabsilber; T Kohnen; M P Holzer
Journal:  Ophthalmologe       Date:  2008-06       Impact factor: 1.059

9.  [Clinical results of a multifocal pseudophakic additional lens].

Authors:  J Schrecker; A Langenbucher
Journal:  Ophthalmologe       Date:  2015-02       Impact factor: 1.059

10.  Optical bench performance of AcrySof(®) IQ ReSTOR(®), AT LISA(®) tri, and FineVision(®) intraocular lenses.

Authors:  Daniel Carson; Warren E Hill; Xin Hong; Mutlu Karakelle
Journal:  Clin Ophthalmol       Date:  2014-10-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.