Literature DB >> 23771652

A technical description of a novel pharmacological anesthesia robot.

Mohamad Wehbe1, Erik Arbeid, Shantale Cyr, Pierre A Mathieu, Riccardo Taddei, Joshua Morse, Thomas M Hemmerling.   

Abstract

To control the three components of general anesthesia (hypnosis, analgesia, and neuromuscular blockade), an automated closed-loop, anesthesia-drug delivery system (McSleepy) was developed. Bispectral index was used as the control variable for hypnosis, the analgoscore for analgesia, and phonomyography for neuromuscular blockade. McSleepy can be used to control the induction, maintenance and emergence from general anesthesia. To do so, a large touch screen is used to provide a user friendly interface, permitting bidirectional communication: the user giving information about the different stages of anesthesia, and the system prompting the anesthesiologist to perform certain actions such as mask ventilation, intubation or waking-up the patient using audio clips with voice commands. Several safety features were implemented to provide a secure and reliable anesthesia. Preliminary results of 15 patients are presented in this paper. Evaluation of McSleepy was done through an assessment of its clinical performance and using Varvel's performance indices. The system was found to be clinically useful by providing good precision in drug administration and reliable results for the duration of a general anesthesia.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23771652     DOI: 10.1007/s10877-013-9451-8

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  14 in total

1.  Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control.

Authors:  A Morley; J Derrick; P Mainland; B B Lee; T G Short
Journal:  Anaesthesia       Date:  2000-10       Impact factor: 6.955

2.  Evaluation of a closed-loop muscle relaxation control system.

Authors:  Douglas J Eleveld; Johannes H Proost; J Mark K H Wierda
Journal:  Anesth Analg       Date:  2005-09       Impact factor: 5.108

3.  The effect of the interaction of propofol and alfentanil on recall, loss of consciousness, and the Bispectral Index.

Authors:  I A Iselin-Chaves; R Flaishon; P S Sebel; S Howell; T J Gan; J Sigl; B Ginsberg; P S Glass
Journal:  Anesth Analg       Date:  1998-10       Impact factor: 5.108

4.  The effect of remifentanil on the bispectral index change and hemodynamic responses after orotracheal intubation.

Authors:  B Guignard; C Menigaux; X Dupont; D Fletcher; M Chauvin
Journal:  Anesth Analg       Date:  2000-01       Impact factor: 5.108

5.  Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

Authors:  M M Struys; T De Smet; L F Versichelen; S Van De Velde; R Van den Broecke; E P Mortier
Journal:  Anesthesiology       Date:  2001-07       Impact factor: 7.892

Review 6.  Clinical assessment of neuromuscular transmission.

Authors:  J Viby-Mogensen
Journal:  Br J Anaesth       Date:  1982-02       Impact factor: 9.166

7.  A new paradigm for the closed-loop intraoperative administration of analgesics in humans.

Authors:  Andrea Gentilini; Christoph Schaniel; Manfred Morari; Christian Bieniok; Rolf Wymann; Thomas Schnider
Journal:  IEEE Trans Biomed Eng       Date:  2002-04       Impact factor: 4.538

8.  Closed-loop control of consciousness during lung transplantation: an observational study.

Authors:  Ngai Liu; Thierry Chazot; Bernard Trillat; Mireille Michel-Cherqui; Jean Yves Marandon; Jean-Dominique Law-Koune; Bertrand Rives; Marc Fischler
Journal:  J Cardiothorac Vasc Anesth       Date:  2008-06-25       Impact factor: 2.628

9.  A new closed-loop control system for isoflurane using bispectral index outperforms manual control.

Authors:  Stephan Locher; Konrad S Stadler; Thomas Boehlen; Thomas Bouillon; Daniel Leibundgut; Peter M Schumacher; Rolf Wymann; Alex M Zbinden
Journal:  Anesthesiology       Date:  2004-09       Impact factor: 7.892

10.  Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study.

Authors:  G D Puri; B Kumar; J Aveek
Journal:  Anaesth Intensive Care       Date:  2007-06       Impact factor: 1.669

View more
  8 in total

1.  Rocuronium: automatic infusion versus manual administration with TOF monitorisation.

Authors:  Fatma Gulcin Ozturk Arikan; Guldem Turan; Asu Ozgultekin; Zubeyir Sivrikaya; Bekir Cem Cosar; Dondu Nisa Onder
Journal:  J Clin Monit Comput       Date:  2015-08-18       Impact factor: 2.502

2.  Closed-loop systems and automation in the era of patients safety and perioperative medicine.

Authors:  Maxime Cannesson; Joseph Rinehart
Journal:  J Clin Monit Comput       Date:  2014-02       Impact factor: 2.502

3.  Use of Robots in Critical Care: Systematic Review.

Authors:  Rachel Teng; Yichen Ding; Kay Choong See
Journal:  J Med Internet Res       Date:  2022-05-16       Impact factor: 7.076

Review 4.  [Perioperative risk and mortality after major surgery].

Authors:  O Boehm; M K A Pfeiffer; G Baumgarten; A Hoeft
Journal:  Anaesthesist       Date:  2015-11       Impact factor: 1.041

5.  A beat-by-beat cardiovascular index, CARDEAN, to titrate opioid administration in the setting of orthopaedic surgery: a prospective randomized trial.

Authors:  Pierre-François Wey; Damien Loheas; Antoine Lamblin; Benjamin Riche; Muriel Rabilloud; Jacques Escarment; Marc Puidupin; Luc Quintin; Jean-Yves Martinez; Andrei Cividjian
Journal:  J Clin Monit Comput       Date:  2020-10-06       Impact factor: 2.502

Review 6.  A Review of Modern Control Strategies for Clinical Evaluation of Propofol Anesthesia Administration Employing Hypnosis Level Regulation.

Authors:  Muhammad Ilyas; Muhammad Fasih Uddin Butt; Muhammad Bilal; Khalid Mahmood; Ali Khaqan; Raja Ali Riaz
Journal:  Biomed Res Int       Date:  2017-03-30       Impact factor: 3.411

Review 7.  Phonomyography on Perioperative Neuromuscular Monitoring: An Overview.

Authors:  Yanjie Dong; Qian Li
Journal:  Sensors (Basel)       Date:  2022-03-22       Impact factor: 3.576

8.  Comparison between High- and Low-Cost Transmission of Tele-Anesthesia in Japan.

Authors:  Yoh Sugawara; Tetsuya Miyashita; Yusuke Mizuno; Yusuke Nagamine; Tomoyuki Miyazaki; Ayako Kobayashi; Kentaro Tojo; Yasuhiro Iketani; Shunsuke Takaki; Takahisa Goto
Journal:  J Healthc Eng       Date:  2018-06-11       Impact factor: 2.682

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.