Literature DB >> 11004108

Use of a portable head mounted perimetry system to assess bedside visual fields.

D A Hollander1, N J Volpe, M L Moster, G T Liu, L J Balcer, K D Judy, S L Galetta.   

Abstract

AIM: This study was designed to test the ability of a portable computer driven, head mounted visual field testing system to perform automated perimetry on patients at their bedside and to compare these results with the "gold standard" for bedside examinations, confrontation visual fields.
METHODS: The Kasha visual field system is a portable automated perimeter which utilises a virtual reality headset. 37 neurosurgery patients were examined at their bedside with a central 24 degree suprathreshold testing strategy after confrontation visual field testing. The patterns of visual field defects were categorised and compared with the results of confrontation testing.
RESULTS: A total of 42 field examinations were completed on 37 patients, and the average testing time for both eyes was 4.8 minutes with the perimetry system. Each of the 11 fields (100%) classified with defects on confrontation testing was similarly categorised on head mounted perimetry. 26 out of 31 (84%) visual fields were normal on both confrontation and perimetry testing, while five out of the 31 fields (16%) which were full on confrontation had visual field defects identified by head mounted perimetry.
CONCLUSION: The head mounted, automated perimetry system proved easily portable and convenient for examining neurosurgical patients at their bedside in the perioperative period. The device demonstrated equal sensitivity to confrontation visual field testing methods in detecting field defects and offers the advantage of standardised, quantifiable testing with graphic results for follow up examinations.

Entities:  

Mesh:

Year:  2000        PMID: 11004108      PMCID: PMC1723249          DOI: 10.1136/bjo.84.10.1185

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  10 in total

1.  Automated suprathreshold static perimetry screening for detecting neuro-ophthalmologic disease.

Authors:  R M Siatkowski; B L Lam; D R Anderson; W J Feuer; A M Halikman
Journal:  Ophthalmology       Date:  1996-06       Impact factor: 12.079

2.  Reliability indexes of automated perimetric tests.

Authors:  J Katz; A Sommer
Journal:  Arch Ophthalmol       Date:  1988-09

3.  Computer-assisted perimetry in visual pathway disease: neuro-ophthalmic applications.

Authors:  B R Younge
Journal:  Trans Am Ophthalmol Soc       Date:  1984

4.  Screening for visual field abnormalities with automated perimetry.

Authors:  J L Keltner; C A Johnson
Journal:  Surv Ophthalmol       Date:  1983 Nov-Dec       Impact factor: 6.048

5.  The efficient use of perimetry for neuro-ophthalmic diagnosis.

Authors:  A Reitner; M Tittl; E Ergun; R Baradaran-Dilmaghani
Journal:  Br J Ophthalmol       Date:  1996-10       Impact factor: 4.638

6.  Reliability of visual field results over repeated testing.

Authors:  J Katz; A Sommer; K Witt
Journal:  Ophthalmology       Date:  1991-01       Impact factor: 12.079

7.  Visual field profile of optic neuritis. One-year follow-up in the Optic Neuritis Treatment Trial.

Authors:  J L Keltner; C A Johnson; J O Spurr; R W Beck
Journal:  Arch Ophthalmol       Date:  1994-07

8.  Confrontation visual field techniques in the detection of anterior visual pathway lesions.

Authors:  J D Trobe; P C Acosta; J P Krischer; G L Trick
Journal:  Ann Neurol       Date:  1981-07       Impact factor: 10.422

9.  Baseline visual field profile of optic neuritis. The experience of the optic neuritis treatment trial. Optic Neuritis Study Group.

Authors:  J L Keltner; C A Johnson; J O Spurr; R W Beck
Journal:  Arch Ophthalmol       Date:  1993-02

10.  Assessing the utility of reliability indices for automated visual fields. Testing ocular hypertensives.

Authors:  M Bickler-Bluth; G L Trick; A E Kolker; D G Cooper
Journal:  Ophthalmology       Date:  1989-05       Impact factor: 12.079

  10 in total
  10 in total

1.  Bilateral Concurrent Eye Examination with a Head-Mounted Perimeter for Diagnosing Functional Visual Loss.

Authors:  Toshiaki Goseki; Hitoshi Ishikawa; Nobuyuki Shoji
Journal:  Neuroophthalmology       Date:  2016-09-20

2.  Toward Improving the Mobility of Patients with Peripheral Visual Field Defects with Novel Digital Spectacles.

Authors:  Ahmed M Sayed; Rashed Kashem; Mostafa Abdel-Mottaleb; Vatookarn Roongpoovapatr; Taher K Eleiwa; Mohamed Abdel-Mottaleb; Richard K Parrish; Mohamed Abou Shousha
Journal:  Am J Ophthalmol       Date:  2019-10-10       Impact factor: 5.258

3.  Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.

Authors:  Stylianos Tsapakis; Dimitrios Papaconstantinou; Andreas Diagourtas; Konstantinos Droutsas; Konstantinos Andreanos; Marilita M Moschos; Dimitrios Brouzas
Journal:  Clin Ophthalmol       Date:  2017-08-07

4.  Comparison of head-mounted perimeter (imo®) and Humphrey Field Analyzer.

Authors:  Tairo Kimura; Chota Matsumoto; Hiroki Nomoto
Journal:  Clin Ophthalmol       Date:  2019-03-14

5.  Eye-Tracking for Clinical Ophthalmology with Virtual Reality (VR): A Case Study of the HTC Vive Pro Eye's Usability.

Authors:  Alexandra Sipatchin; Siegfried Wahl; Katharina Rifai
Journal:  Healthcare (Basel)       Date:  2021-02-09

6.  Sensitivity and Specificity of New Visual Field Screening Software for Diagnosing Hemianopia.

Authors:  Supharat Jariyakosol; Patcharaporn Jaru-Ampornpan; Anita Manassakorn; Rath Itthipanichpong; Parima Hirunwiwatkul; Visanee Tantisevi; Thanapong Somkijrungroj; Prin Rojanapongpun
Journal:  Eye Brain       Date:  2021-08-29

7.  Advanced Vision Analyzer-Virtual Reality Perimeter: Device Validation, Functional Correlation and Comparison with Humphrey Field Analyzer.

Authors:  Priya Narang; Amar Agarwal; Maheswari Srinivasan; Ashvin Agarwal
Journal:  Ophthalmol Sci       Date:  2021-06-25

Review 8.  A critical review: Psychophysical assessments of diabetic retinopathy.

Authors:  Xing D Chen; Thomas W Gardner
Journal:  Surv Ophthalmol       Date:  2020-08-29       Impact factor: 6.048

9.  Testing of visual field with virtual reality goggles in manual and visual grasp modes.

Authors:  Dariusz Wroblewski; Brian A Francis; Alfredo Sadun; Ghazal Vakili; Vikas Chopra
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

10.  Visual Field Testing with Head-Mounted Perimeter 'imo'.

Authors:  Chota Matsumoto; Sayaka Yamao; Hiroki Nomoto; Sonoko Takada; Sachiko Okuyama; Shinji Kimura; Kenzo Yamanaka; Makoto Aihara; Yoshikazu Shimomura
Journal:  PLoS One       Date:  2016-08-26       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.