Measurement of half-value layer in x-ray CT: a comparison of two noninvasive techniques.

R L Kruger1, C H McCollough, F E Zink.   

Abstract

The purpose of this paper is to determine the accuracy and reproducibility of two noninvasive methods of measuring half-value layer (HVL), ring and localization, compared with an invasive technique (suspending tube rotation). The ring method uses concentric aluminum rings about a CTDI ionization chamber at isocenter. Data were acquired using axial CT protocols (rotating x-ray tube, stationary patient table). The localization technique uses square aluminum sheets secured to the gantry shroud to filter the radiation beam, and a CTDI chamber suspended externally at isocenter. Data were acquired using localization image protocols (stationary x-ray tube, moving patient table). The invasive technique was similar to the localization technique except that the ion chamber was placed on the patient table and the tube rotation disabled using service software. Data for all techniques were collected on the same CT system. Independent data sets were collected to determine reproducibility. Sensitivity to ionization chamber lateral displacement from isocenter was investigated. Measured HVLs (mm aluminum, mean+/-std, n=4) were 7.19+/-0.03 (ring); 7.17+/-0.04 (localization); and 7.24+/-0.02 (service mode), which were not significantly different (p = 0.05). Displacing the chamber from isocenter changes the HVL, depending on the bow-tie filter, by as much as 5 mm aluminum. Aluminum filter to ion chamber distances of 25-35 cm provided accurate results. Both noninvasive techniques were accurate and reproducible at isocenter. However, the measured HVL was dependent upon the bow-tie filter and the lateral displacement of the ionization chamber with respect to isocenter. Greater than 2 cm off of isocenter, the ring technique did not provide accurate HVL measurements.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10984237     DOI: 10.1118/1.1287440

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

Authors:  Kelsey B Mathieu; Michael F McNitt-Gray; Di Zhang; Hyun J Kim; Dianna D Cody
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  An empirical model of diagnostic x-ray attenuation under narrow-beam geometry.

Authors:  Kelsey B Mathieu; S Cheenu Kappadath; R Allen White; E Neely Atkinson; Dianna D Cody
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

4.  Partial arc beam filtration: a novel approach to reducing CT breast radiation dose.

Authors:  Kelsey B Mathieu; Dianna D Cody
Journal:  AJR Am J Roentgenol       Date:  2013-03       Impact factor: 3.959

5.  Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations.

Authors:  Bria M Moore; Samuel L Brady; Amy E Mirro; Robert A Kaufman
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe.

Authors:  Sarah E McKenney; Anita Nosratieh; Dale Gelskey; Kai Yang; Shin-Ying Huang; Lin Chen; John M Boone
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems.

Authors:  Jack L Glover; Lawrence T Hudson
Journal:  Meas Sci Technol       Date:  2016-05-11       Impact factor: 2.046

8.  Real-time dosimeter employed to evaluate the half-value layer in CT.

Authors:  Sarah E McKenney; J Anthony Seibert; George W Burkett; Dale Gelskey; Paul B Sunde; James D Newman; John M Boone
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

9.  Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners.

Authors:  Narumi Taguchi; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Yoshinori Funama; Masanori Imuta; Hideaki Yuki; Yasunori Nagayama; Masafumi Kidoh; Kenichiro Hirata; Yuji Iyama; Tomohiro Namimoto; Noriyuki Kai; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2017-11-06       Impact factor: 3.039

10.  Direct and fast measurement of CT beam filter profiles with simultaneous geometrical calibration.

Authors:  Kai Yang; Xinhua Li; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.