An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems.

Jack L Glover1, Lawrence T Hudson2.   

Abstract

The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in a US national aviation security standard.

Entities:  

Keywords:  ASTM standards; IEEE/ANSI standards; aviation security; bomb squads; image processing; object detection; portable x-ray systems; useful penetration; wire detection; x-ray imaging

Year:  2016        PMID: 27499586      PMCID: PMC4971577          DOI: 10.1088/0957-0233/27/6/065402

Source DB:  PubMed          Journal:  Meas Sci Technol        ISSN: 0957-0233            Impact factor:   2.046


  3 in total

1.  Measurement of half-value layer in x-ray CT: a comparison of two noninvasive techniques.

Authors:  R L Kruger; C H McCollough; F E Zink
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

2.  Measurements and standards for bulk-explosives detection.

Authors:  Larry Hudson; Fred Bateman; Paul Bergstrom; Frank Cerra; Jack Glover; Ronaldo Minniti; Stephen Seltzer; Ronald Tosh
Journal:  Appl Radiat Isot       Date:  2011-11-23       Impact factor: 1.513

3.  The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology.

Authors: 
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.