Literature DB >> 10976122

Meniscal repair devices.

F A Barber1, M A Herbert.   

Abstract

Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

Mesh:

Year:  2000        PMID: 10976122     DOI: 10.1053/jars.2000.4819

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  18 in total

1.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

2.  Evaluation of the second-generation meniscus arrow in the fixation of bucket-handle tears in the vascular area of the meniscus. A prospective study of 20 patients with a mean follow-up of 26 months.

Authors:  Janne Sarimo; Jussi Rantanen; Tapio Tarvainen; Markku Härkönen; Sakari Orava
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-05-05       Impact factor: 4.342

3.  Modified cruciate suture technique for arthroscopic meniscal repair: a technical note.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-02-13       Impact factor: 4.342

4.  Biomechanical evaluation of arthroscopic all-inside meniscus repairs.

Authors:  Taner Gunes; Bora Bostan; Mehmet Erdem; Murat Asci; Cengiz Sen; Mehmet Halidun Kelestemur
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

5.  Tensile forces on sutures in the human lateral knee meniscus.

Authors:  Christian Staerke; Olaf Brettschneider; Karl-Heinz Gröbel; Roland Becker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

6.  Short- to mid-term results of arthroscopic meniscal repair of long vertical longitudinal tears using combined cruciate and horizontal suture techniques: a retrospective study.

Authors:  Ashraf Abdelkafy
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-05-28

7.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

Review 8.  [Complications with all-inside devices used in reconstructive meniscal surgery].

Authors:  P Wilmes; O Lorbach; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

Review 9.  Treatment of meniscal tears: An evidence based approach.

Authors:  Simon C Mordecai; Nawfal Al-Hadithy; Howard E Ware; Chinmay M Gupte
Journal:  World J Orthop       Date:  2014-07-18

10.  A biomechanical comparison of all-inside meniscus repair techniques.

Authors:  Jen-Huei Chang; Hsain-Chung Shen; Guo-Shu Huang; Ru-Yu Pan; Chi-Fang Wu; Chian-Her Lee; Qian Chen
Journal:  J Surg Res       Date:  2008-11-06       Impact factor: 2.192

View more