Literature DB >> 19328497

A biomechanical comparison of all-inside meniscus repair techniques.

Jen-Huei Chang1, Hsain-Chung Shen, Guo-Shu Huang, Ru-Yu Pan, Chi-Fang Wu, Chian-Her Lee, Qian Chen.   

Abstract

BACKGROUND: The aim of this study was to assess the biomechanical characteristics of six all-inside meniscal single suture repair techniques using a porcine model.
MATERIALS AND METHODS: Peripheral longitudinal tears were created in freshly isolated porcine menisci. Tears were repaired using the single vertical technique with six different repair complexes including those involving sutures (#2 FiberWire, #2 Ethibone, flexible anchors (Fast-Fix, RapidLoc), and rigid anchors (Meniscal-Dart, BioStinger). Displacement, ultimate failure strength, stiffness, and site of failure were measured using a Materials Testing System machine. An initial 2 N preload was applied, followed by loading between 5 and 20 N for 300 cycles. Failure strength was determined lastly by increasing tension at a rate of 5 mm/min until failure.
RESULTS: Failure strength was highest in the #2 FiberWire group (175.6 N). This was significantly higher than in all other groups (P < 0.05). The second highest failure load was evident in the #2 Ethibone group (113.8 N). This was significantly higher than in all other groups bar the #2 FiberWire group (P < 0.05). Stiffness was also significantly higher in the #2 FiberWire group compared with all other groups (8.5 N/mm, P < 0.05). There were no between-group differences in displacement. When grouped by repair technique, failure load was significantly higher, and displacement was significantly lower, in suture compared with both flexible and rigid anchor repaired menisci (P < 0.01 for all comparisons). Although stiffness was also higher in the suture group, there were no significant between-group differences detected.
CONCLUSIONS: Suture techniques exhibited biomechanical superiority over biodegradable flexible and rigid anchor devices for meniscus repair.

Entities:  

Mesh:

Year:  2008        PMID: 19328497      PMCID: PMC2896296          DOI: 10.1016/j.jss.2008.10.002

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  22 in total

1.  Cyclic testing of meniscal sutures.

Authors:  R Seil; S Rupp; D M Kohn
Journal:  Arthroscopy       Date:  2000 Jul-Aug       Impact factor: 4.772

Review 2.  All-inside meniscus repair: a systematic review.

Authors:  Jesus Lozano; C Benjamin Ma; W Dilworth Cannon
Journal:  Clin Orthop Relat Res       Date:  2007-02       Impact factor: 4.176

Review 3.  The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment.

Authors:  K Messner; J Gao
Journal:  J Anat       Date:  1998-08       Impact factor: 2.610

4.  Results of isolated meniscal repair evaluated by second-look arthroscopy.

Authors:  S Horibe; K Shino; A Maeda; N Nakamura; N Matsumoto; T Ochi
Journal:  Arthroscopy       Date:  1996-04       Impact factor: 4.772

5.  Failure strengths of different meniscal suturing techniques.

Authors:  M G Rimmer; N S Nawana; G C Keene; M J Pearcy
Journal:  Arthroscopy       Date:  1995-04       Impact factor: 4.772

6.  Meniscus bucket-handle fixation with an absorbable Biofix tack: development of a new technique.

Authors:  P Albrecht-Olsen; G Kristensen; P Törmälä
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1993       Impact factor: 4.342

7.  [Biomechanics of the knee joint after meniscus resection. Stress analysis of the cadaver knee].

Authors:  O Paar; M N Magin; J Nachtkamp
Journal:  Chirurg       Date:  1995-06       Impact factor: 0.955

8.  The effect of medial meniscectomy on strain distribution in the proximal part of the tibia.

Authors:  R B Bourne; J B Finlay; P Papadopoulos; P Andreae
Journal:  J Bone Joint Surg Am       Date:  1984-12       Impact factor: 5.284

9.  Load to failure of common meniscal repair techniques: effects of suture technique and suture material.

Authors:  W R Post; S R Akers; V Kish
Journal:  Arthroscopy       Date:  1997-12       Impact factor: 4.772

10.  Interspecies variation of compressive biomechanical properties of the meniscus.

Authors:  M D Joshi; J K Suh; T Marui; S L Woo
Journal:  J Biomed Mater Res       Date:  1995-07
View more
  6 in total

1.  The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

2.  Lateral meniscus allograft transplantation using a single-incision technique.

Authors:  Ki-Mo Jang; Joon Ho Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-03       Impact factor: 4.342

3.  The effect of inclination angle on the strength of vertical mattress configuration for meniscus repair.

Authors:  Mehmet Erduran; Onur Hapa; Baran Şen; Yavuz Kocabey; Diler Erdemli; Mehran Aksel; Hasan Havitçioğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-09       Impact factor: 4.342

4.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

5.  Influence of peracetic acid-ethanol sterilisation on the biomechanical properties of human meniscus transplants.

Authors:  Volker Eras; Josefine Graffunder; Norus Ahmed; Jan C Brune
Journal:  J Exp Orthop       Date:  2021-03-05

6.  Arthroscopic repair of the meniscal injury using meniscal repair device.

Authors:  Tang Hengtao; Su Xuntong
Journal:  Indian J Orthop       Date:  2015 Sep-Oct       Impact factor: 1.251

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.