Literature DB >> 10960539

Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique.

F Laurent1, V Latrabe, B Vergier, P Michel.   

Abstract

PURPOSE: To compare the accuracy and complication rate of two different CT-guided transthoracic needle biopsy techniques: fine needle aspiration and an automated biopsy device.
METHODS: Two consecutive series of respectively 125 (group A) and 98 (group B) biopsies performed using 20-22 gauge coaxial fine needle aspiration (group A) and an automated 19.5 gauge coaxial biopsy device (group B) were compared in terms of their accuracy and complication rate.
RESULTS: Groups A and B included respectively 100 (80%) and 77 (79%) malignant lesions and 25 (20%) and 18 (21%) benign lesions. No significant difference was found between the two series concerning patients, lesions, and procedural variables. For a diagnosis of malignancy, a statistically significant difference in sensitivity was found (82.7% vs 97.4%) between results obtained with the automated biopsy device and fine needle aspiration respectively. For a diagnosis of malignancy, the false negative rate of the biopsy result was significantly higher (p <0.005) in group A (17%) than in group B (2.6%). For a specific diagnosis of benignity, no statistically significant difference was found between the two groups (44% vs 26%) but the automated biopsy device provided fewer indeterminate cases. There was no difference between the two groups concerning the pneumothorax rate, which was 20% in group A and 15% in group B, or the hemoptysis rate, which was 2.4% in group A and 4% in group B.
CONCLUSION: For a diagnosis of malignancy when a cytopathologist is not available on-site, automated biopsy devices provide a lower rate of false negative results and a similar complication rate to fine needle aspiration.

Entities:  

Mesh:

Year:  2000        PMID: 10960539     DOI: 10.1007/s002700010067

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  37 in total

1.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

2.  Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules.

Authors:  Massimo De Filippo; Luca Saba; Giorgio Concari; Rita Nizzoli; Lilia Ferrari; Marcello Tiseo; Andrea Ardizzoni; Nicola Sverzellati; Ilaria Paladini; Chiara Ganazzoli; Luca Maria Sconfienza; Giampaolo Carrafiello; Luca Brunese; Eugenio Annibale Genovese; Luca Ampollini; Paolo Carbognani; Michele Rusca; Maurizio Zompatori; Cristina Rossi
Journal:  Radiol Med       Date:  2013-07-25       Impact factor: 3.469

Review 3.  Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature.

Authors:  Emanuela Capalbo; Michela Peli; Maria Lovisatti; Maria Cosentino; Paola Mariani; Eisabetta Berti; Maurizio Cariati
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

4.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

5.  Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.

Authors:  Çağlar Uzun; Zehra Akkaya; Ebru Düşünceli Atman; Evren Üstüner; Elif Peker; Başak Gülpınar; Atilla Halil Elhan; Koray Ceyhan; Kayhan Çetin Atasoy
Journal:  Diagn Interv Radiol       Date:  2017 Mar-Apr       Impact factor: 2.630

6.  Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.

Authors:  Jung Im Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

7.  Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy.

Authors:  Takuji Yamagami; Rika Yoshimatsu; Kenji Kajiwara; Masaki Ishikawa; Tomohiro Matsumoto; Hideaki Kakizawa; Naoyuki Toyoda; Terumitsu Hasebe; Kazuo Awai
Journal:  Eur Radiol       Date:  2014-02-14       Impact factor: 5.315

8.  [CT-guided cutting needle biopsies of thoracic lesions in patients with negative bronchoscopic findings].

Authors:  W Gross-Fengels; K Koreuber; P Siemens; H Kastendieck; G Wiest; C Kugler; M Semik
Journal:  Radiologe       Date:  2011-04       Impact factor: 0.635

9.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

10.  Number of biopsies in diagnosing pulmonary nodules.

Authors:  M Wehrschuetz; E Wehrschuetz; H R Portugaller
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2010-07-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.