Literature DB >> 10921936

Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma.

A Erice1, D Brambilla, J Bremer, J B Jackson, R Kokka, B Yen-Lieberman, R W Coombs.   

Abstract

The QUANTIPLEX HIV-1 RNA assay, version 3.0 (a branched DNA, version 3.0, assay [bDNA 3.0 assay]), was evaluated by analyzing spiked and clinical plasma samples and was compared with the AMPLICOR HIV-1 MONITOR Ultrasensitive (ultrasensitive reverse transcription-PCR [US-RT-PCR]) method. A panel of spiked plasma samples that contained 0 to 750,000 copies of human immunodeficiency virus type 1 (HIV-1) RNA per ml was tested four times in each of four laboratories (1,344 assays). Negative results (<50 copies/ml) were obtained in 30 of 32 (94%) assays with seronegative samples, 66 of 128 (52%) assays with HIV-1 RNA at 50 copies/ml, and 5 of 128 (4%) assays with HIV-1 RNA at 100 copies/ml. The assay was linear from 100 to 500,000 copies/ml. The within-run standard deviation (SD) of the log(10) estimated HIV-1 RNA concentration was 0.08 at 1,000 to 500,000 copies/ml, increased below 1,000 copies/ml, and was 0.17 at 100 copies/ml. Between-run reproducibility at 100 to 500 copies/ml was <0.10 log(10) in most comparisons. Interlaboratory differences across runs were </=0.10 log(10) at all concentrations examined. A subset of the panel (25 to 500 copies/ml) was also analyzed by the US-RT-PCR assay. The within-run SD varied inversely with the log(10) HIV-1 RNA concentration but was higher than the SD for the bDNA 3.0 assay at all concentrations. Log-log regression analysis indicated that the two methods produced very similar estimates at 100 to 500 copies/ml. In parallel testing of clinical specimens with low HIV-1 RNA levels, 80 plasma samples with <50 copies/ml by the US-RT-PCR assay had <50 copies/ml when they were retested by the bDNA 3.0 assay. In contrast, 11 of 78 (14%) plasma samples with <50 copies/ml by the bDNA 3.0 assay had >/=50 copies/ml when they were retested by the US-RT-PCR assay (median, 86 copies/ml; range, 50 to 217 copies/ml). Estimation of bDNA 3.0 values of <50 copies/ml by extending the standard curve of the assay showed that these samples with discrepant results had higher HIV-1 RNA levels than the samples with concordant results (median, 34 versus 17 copies/ml; P = 0.0051 by the Wilcoxon two-sample test). The excellent reproducibility, broad linear range, and good sensitivity of the bDNA 3.0 assay make it a very attractive method for quantitation of HIV-1 RNA levels in plasma.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10921936      PMCID: PMC87124     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  23 in total

1.  Viral load and disease progression in infants infected with human immunodeficiency virus type 1. Women and Infants Transmission Study Group.

Authors:  W T Shearer; T C Quinn; P LaRussa; J F Lew; L Mofenson; S Almy; K Rich; E Handelsman; C Diaz; M Pagano; V Smeriglio; L A Kalish
Journal:  N Engl J Med       Date:  1997-05-08       Impact factor: 91.245

2.  A rapid and simple method for extracting human immunodeficiency virus type 1 RNA from plasma: enhanced sensitivity.

Authors:  J Mulder; R Resnick; B Saget; S Scheibel; S Herman; H Payne; R Harrigan; S Kwok
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

Review 3.  Antiretroviral therapy in adults: updated recommendations of the International AIDS Society-USA Panel.

Authors:  C C Carpenter; D A Cooper; M A Fischl; J M Gatell; B G Gazzard; S M Hammer; M S Hirsch; D M Jacobsen; D A Katzenstein; J S Montaner; D D Richman; M S Saag; M Schechter; R T Schooley; M A Thompson; S Vella; P G Yeni; P A Volberding
Journal:  JAMA       Date:  2000-01-19       Impact factor: 56.272

4.  Evaluation of a quality assurance program for quantitation of human immunodeficiency virus type 1 RNA in plasma by the AIDS Clinical Trials Group virology laboratories.

Authors:  B Yen-Lieberman; D Brambilla; B Jackson; J Bremer; R Coombs; M Cronin; S Herman; D Katzenstein; S Leung; H J Lin; P Palumbo; S Rasheed; J Todd; M Vahey; P Reichelderfer
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

5.  HIV-1 dynamics in vivo: virion clearance rate, infected cell life-span, and viral generation time.

Authors:  A S Perelson; A U Neumann; M Markowitz; J M Leonard; D D Ho
Journal:  Science       Date:  1996-03-15       Impact factor: 47.728

6.  Residual HIV-1 RNA in blood plasma of patients taking suppressive highly active antiretroviral therapy.

Authors:  G Dornadula; H Zhang; B VanUitert; J Stern; L Livornese; M J Ingerman; J Witek; R J Kedanis; J Natkin; J DeSimone; R J Pomerantz
Journal:  JAMA       Date:  1999-11-03       Impact factor: 56.272

7.  Comparison of the Quantiplex version 3.0 assay and a sensitized Amplicor monitor assay for measurement of human immunodeficiency virus type 1 RNA levels in plasma samples.

Authors:  H C Highbarger; W G Alvord; M K Jiang; A S Shah; J A Metcalf; H C Lane; R L Dewar
Journal:  J Clin Microbiol       Date:  1999-11       Impact factor: 5.948

8.  Rapid and precise quantification of HIV-1 RNA in plasma using a branched DNA signal amplification assay.

Authors:  C Pachl; J A Todd; D G Kern; P J Sheridan; S J Fong; M Stempien; B Hoo; D Besemer; T Yeghiazarian; B Irvine
Journal:  J Acquir Immune Defic Syndr Hum Retrovirol       Date:  1995-04-15

9.  Quantification of HIV-1 RNA in plasma using NASBA during HIV-1 primary infection.

Authors:  B van Gemen; T Kievits; R Schukkink; D van Strijp; L T Malek; R Sooknanan; H G Huisman; P Lens
Journal:  J Virol Methods       Date:  1993-07       Impact factor: 2.014

10.  Prognosis in HIV-1 infection predicted by the quantity of virus in plasma.

Authors:  J W Mellors; C R Rinaldo; P Gupta; R M White; J A Todd; L A Kingsley
Journal:  Science       Date:  1996-05-24       Impact factor: 47.728

View more
  10 in total

1.  Strengths and limitations of commercial tests for hepatitis C virus RNA quantification.

Authors:  Chihiro Morishima; Minjun Chung; Ka Wing Ng; Donald J Brambilla; David R Gretch
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

2.  Intra- and interlaboratory variabilities of results obtained with the Quantiplex human immunodeficiency virus type 1 RNA bDNA assay, version 3.0.

Authors:  J A Kellogg; P V Atria; J C Sanders; M E Eyster
Journal:  Clin Diagn Lab Immunol       Date:  2001-05

3.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

4.  Comparison of two human immunodeficiency virus (HIV) RNA surrogate assays to the standard HIV RNA assay.

Authors:  Cheryl Jennings; Susan A Fiscus; Suzanne M Crowe; Aleksandra D Danilovic; Ralph J Morack; Salvatore Scianna; Ada Cachafeiro; Donald J Brambilla; Jorg Schupbach; Wendy Stevens; Richard Respess; Oliviero E Varnier; Gary E Corrigan; J Simon Gronowitz; Michael A Ussery; James W Bremer
Journal:  J Clin Microbiol       Date:  2005-12       Impact factor: 5.948

5.  Real-time PCR quantification of genital shedding of herpes simplex virus (HSV) and human immunodeficiency virus (HIV) in women coinfected with HSV and HIV.

Authors:  Jérôme Legoff; Hicham Bouhlal; Gérard Grésenguet; Helen Weiss; Nzambi Khonde; Hakim Hocini; Nathalie Désiré; Ali Si-Mohamed; Jean de Dieu Longo; Cécile Chemin; Eric Frost; Jacques Pépin; Jean-Elie Malkin; Philippe Mayaud; Laurent Bélec
Journal:  J Clin Microbiol       Date:  2006-02       Impact factor: 5.948

6.  Evaluation of the clinical sensitivities of three viral load assays with plasma samples from a pediatric population predominantly infected with human immunodeficiency virus type 1 subtype G and BG recombinant forms.

Authors:  Rute Antunes; Sofia Figueiredo; Inês Bártolo; Manuel Pinheiro; Lino Rosado; Isabel Soares; Helena Lourenço; Nuno Taveira
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

7.  HIV dynamics in seminal plasma during primary HIV infection.

Authors:  Joanne Stekler; Brian J Sycks; Sarah Holte; Janine Maenza; Claire E Stevens; Joan Dragavon; Ann C Collier; Robert W Coombs
Journal:  AIDS Res Hum Retroviruses       Date:  2008-10       Impact factor: 2.205

8.  Multicenter evaluation of the performance characteristics of the NucliSens HIV-1 QT assay used for quantitation of human immunodeficiency virus type 1 RNA.

Authors:  Christine C Ginocchio; Marti Kemper; Kathleen A Stellrecht; Donald J Witt
Journal:  J Clin Microbiol       Date:  2003-01       Impact factor: 5.948

9.  RT-PCR detection of HIV in Republic of Macedonia.

Authors:  Golubinka Bosevska; Nikola Panovski; Eleni Dokić; Violeta Grunevska
Journal:  Bosn J Basic Med Sci       Date:  2008-11       Impact factor: 3.363

10.  Highly sensitive multiplex assay for detection of human immunodeficiency virus type 1 and hepatitis C virus RNA.

Authors:  C Giachetti; J M Linnen; D P Kolk; J Dockter; K Gillotte-Taylor; M Park; M Ho-Sing-Loy; M K McCormick; L T Mimms; S H McDonough
Journal:  J Clin Microbiol       Date:  2002-07       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.