Literature DB >> 10901456

Effect of temporal sampling on evaluation of left ventricular ejection fraction by means of thallium-201 gated SPET: comparison of 16- and 8-interval gating, with reference to equilibrium radionuclide angiography.

A Manrique1, R Koning, A Cribier, P Véra.   

Abstract

Gated myocardial single-photon emission tomography (SPET) allows the evaluation of left ventricular ejection fraction (LVEF), but temporal undersampling may lead to systolic truncation and ejection fraction underestimation. The aim of this study was to evaluate the impact of temporal sampling on thallium gated SPET LVEF measurements. Fifty-five consecutive patients (46 men, mean age 62+/-12 years) with a history of myocardial infarction (anterior 31, inferior 24) were studied. All patients underwent equilibrium radionuclide angiography (ERNA) and gated SPET 4 h after a rest injection of 185 MBq (5 mCi) of thallium-201 using either 8-interval (group 1, n=25) or 16-interval gating (group 2, n=30). In group 2, gated SPET acquisitions were automatically resampled to an 8-interval data set. Projection data were reconstructed using filtered back-projection (Butterworth filter, order 5, cut-off 0.20). LVEF was then calculated using commercially available software (QGS). A higher correlation between gated SPET and ERNA was obtained with 16-interval gating (r=0.94) compared with the resampled data set (r=0.84) and 8-interval gating (r=0.71). Bland-Altman plots showed a dramatic improvement in the agreement between gated SPET and ERNA with 16-interval gating (mean difference: -0.10%+/-5%). Using multiple ANOVA, temporal sampling was the only parameter to influence the difference between the two methods. When using 8-interval gating, gated SPET LVEF was overestimated in women and underestimated in men (ERNA minus gated SPET = -4.0%+/-9.6% in women and 3.6%+/-7.6% in men, P=0.01). In conclusion, 16-interval thallium gated SPET offered the best correlation and agreement with ERNA, and should be preferred to 8-interval gated acquisition for LVEF measurement.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10901456     DOI: 10.1007/s002590050564

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

Review 2.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

3.  Should early post-stress imaging be performed on a routine clinical basis for myocardial perfusion studies?

Authors:  Raymond Taillefer
Journal:  J Nucl Cardiol       Date:  2014-09-12       Impact factor: 5.952

4.  Factors affecting accuracy of ventricular volume and ejection fraction measured by gated tl-201 myocardial perfusion single photon emission computed tomography.

Authors:  Moonsun Pai; You-Jung Yang; Ki Chun Im; Il Ki Hong; Sung Cheol Yun; Duk-Hyun Kang; Jae-Kwan Song; Dae Hyuk Moon
Journal:  Int J Cardiovasc Imaging       Date:  2006-05-12       Impact factor: 2.357

5.  Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement.

Authors:  Darshan Godkar; Kalyan Bachu; Bijal Dave; Robert Megna; Selva Niranjan; Ashok Khanna
Journal:  J Natl Med Assoc       Date:  2007-11       Impact factor: 1.798

6.  Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times.

Authors:  Marine Claudin; Laetitia Imbert; Wassila Djaballah; Nicolas Veran; Sylvain Poussier; Véronique Roch; Mathieu Perrin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2016-09-27       Impact factor: 5.952

7.  Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.

Authors:  Alain Manrique; Anne Hitzel; Pierre Véra
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

8.  Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.

Authors:  Taek-Soo Lee; Takahiro Higuchi; Riikka Lautamäki; Frank M Bengel; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2015-08-24       Impact factor: 3.609

9.  Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure.

Authors:  Maryam Shojaeifard; Tahereh Ghaedian; Nahid Yaghoobi; Hadi Malek; Hasan Firoozabadi; Ahmad Bitarafan-Rajabi; Majid Haghjoo; Ahmad Amin; Nasrin Azizian; Feridoon Rastgou
Journal:  Res Cardiovasc Med       Date:  2015-12-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.