Literature DB >> 10892923

Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations.

C J DiCorte1, P Latham, P E Greilich, M V Cooley, P A Grayburn, M E Jessen.   

Abstract

BACKGROUND: Perioperative management of cardiac surgical patients frequently mandates measurements of cardiac output and left ventricular filling. This study compared cardiac output and left ventricular filling measured by pulmonary artery (PA) catheter and esophageal Doppler monitor (EDM).
METHODS: Thirty-four patients undergoing coronary artery bypass grafting were prepared by implanting a PA catheter, an EDM, and a transit-time ultrasonic flow probe around the ascending aorta. In 20 patients, left ventricular end-diastolic short-axis area (EDA) was measured by transesophageal echocardiography. At five time points, cardiac output was measured from the flow probe, the EDM, and the PA catheter (by thermodilution), and left ventricular filling was assessed from the PA catheter (as PA diastolic pressure), the EDM (corrected flow time), and the EDA. For cardiac output, concordance correlations relating EDM to flow probe and PA catheter to flow probe were calculated, transformed (Fisher's z transformation), and compared by Student's t test. For left ventricular filling, regression coefficients were created between corrected flow time and EDA and between PA diastolic pressure and EDA. Spearman correlations were compared by Wilcoxon rank sum test.
RESULTS: The EDM and the PA catheter exhibited similar relationships to the flow probe (concordance correlations, 0.55 +/- 0.35 [mean +/- standard deviation] and 0.49 +/- 0.34, respectively; p = 0.088). The correlation between corrected flow time and EDA was better than the correlation between PA diastolic pressure and EDA (concordance correlations, 0.49 +/- 0.55 versus 0.10 +/- 0.43, respectively; p < 0.01).
CONCLUSIONS: These data suggest that the EDM may offer a less invasive technique for evaluating cardiac output and a more accurate estimate for preload compared with the PA catheter.

Entities:  

Mesh:

Year:  2000        PMID: 10892923     DOI: 10.1016/s0003-4975(00)01129-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  18 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

Review 2.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

Review 3.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

4.  Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response.

Authors:  Fabrice Vallée; Olivier Fourcade; Olivier De Soyres; Olivier Angles; Pascale Sanchez-Verlaan; Fabien Pillard; Nadia Smail; Michel Olivier; Michèle Genestal; Kamran Samii
Journal:  Intensive Care Med       Date:  2005-08-19       Impact factor: 17.440

5.  Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting.

Authors:  Glen Atlas; David Brealey; Sunil Dhar; Gerhard Dikta; Meryvn Singer
Journal:  J Clin Monit Comput       Date:  2012-08-15       Impact factor: 2.502

6.  Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum.

Authors:  A Okrainec; S Bergman; S Demyttenaere; L S Feldman; A Nutting; F Carli; G M Fried
Journal:  Surg Endosc       Date:  2007-01-19       Impact factor: 4.584

Review 7.  Left ventricular diastolic dysfunction of the cardiac surgery patient; a point of view for the cardiac surgeon and cardio-anesthesiologist.

Authors:  Efstratios E Apostolakis; Nikolaos G Baikoussis; Haralabos Parissis; Stavros N Siminelakis; Georgios S Papadopoulos
Journal:  J Cardiothorac Surg       Date:  2009-11-24       Impact factor: 1.637

8.  [Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].

Authors:  J Reutershan; T Kapp; K Unertl; R Fretschner
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

9.  Optimization of cardiac preload during laparoscopic donor nephrectomy: a preliminary study of central venous pressure versus esophageal Doppler monitoring.

Authors:  L S Feldman; M Anidjar; P Metrakos; D Stanbridge; G M Fried; F Carli
Journal:  Surg Endosc       Date:  2004-01-14       Impact factor: 4.584

Review 10.  Clinical review: Goal-directed therapy in high risk surgical patients.

Authors:  Nicholas Lees; Mark Hamilton; Andrew Rhodes
Journal:  Crit Care       Date:  2009-10-26       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.