Literature DB >> 17235722

Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum.

A Okrainec1, S Bergman, S Demyttenaere, L S Feldman, A Nutting, F Carli, G M Fried.   

Abstract

BACKGROUND: Commonly used perioperative measurements of hemodynamics, such as Swan-Ganz catheter assessment, are invasive and may not be reliable under pneumoperitoneum. The purpose of this study was to validate the use of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum in an experimental pig model.
METHODS: Eight female pigs were submitted to two 30-min study periods, one each for the baseline (no interventions) and pneumoperitoneum (12-mmHg carbon dioxide pneumoperitoneum) conditions. One pig was excluded because of tachycardia (>140 at baseline). A Swan-Ganz pulmonary artery catheter was used to measure cardiac output (CO-SG) and pulmonary capillary wedge pressure (PCWP). An esophageal Doppler probe was inserted to record cardiac output (CO-ED) and corrected flow time (FTc), an index of preload. Transthoracic echocardiography was used to measure left ventricular end-diastolic diameter (LVEDD) and cardiac output (CO-TTE). Pearson correlation was used to assess individual associations between the measured hemodynamic parameters.
RESULTS: There was good correlation between CO-ED and CO-SG (r = 0.577; p < 0.001) and excellent correlation between CO-ED and CO-TTE (r = 0.815; p < 0.001). There was no correlation between FTc and LVEDD or PCWP. These relationships were consistent when analyzed separately at baseline and during pneumoperitoneum.
CONCLUSION: Esophageal Doppler monitoring is a valid noninvasive method of estimating cardiac output at baseline and during pneumoperitoneum in a porcine model. Corrected flow time did not correlate with other estimates of preload at baseline or during pneumoperitoneum.

Entities:  

Mesh:

Year:  2007        PMID: 17235722     DOI: 10.1007/s00464-006-9106-7

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  27 in total

1.  Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations.

Authors:  C J DiCorte; P Latham; P E Greilich; M V Cooley; P A Grayburn; M E Jessen
Journal:  Ann Thorac Surg       Date:  2000-06       Impact factor: 4.330

2.  A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.

Authors:  James Dean Sandham; Russell Douglas Hull; Rollin Frederick Brant; Linda Knox; Graham Frederick Pineo; Christopher J Doig; Denny P Laporta; Sidney Viner; Louise Passerini; Hugh Devitt; Ann Kirby; Michael Jacka
Journal:  N Engl J Med       Date:  2003-01-02       Impact factor: 91.245

3.  Laparoscopic colorectal surgery in the complicated patient.

Authors:  Margaret D Plocek; Daniel P Geisler; Edward J Glennon; Phillip Kondylis; John C Reilly
Journal:  Am J Surg       Date:  2005-12       Impact factor: 2.565

4.  Esophageal Doppler (ODM II) improves intraoperative hemodynamic monitoring during laparoscopic surgery.

Authors:  Alexander Koliopanos; George Zografos; Sotirios Skiathitis; Dionisios Stithos; Vasiliki Voukena; Andreas Karampinis; George Papastratis
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2005-12       Impact factor: 1.719

5.  Effects of posture and pneumoperitoneum during anaesthesia on the indices of left ventricular filling.

Authors:  P Gannedahl; S Odeberg; L A Brodin; A Sollevi
Journal:  Acta Anaesthesiol Scand       Date:  1996-02       Impact factor: 2.105

6.  Assessment of cardiovascular changes during laparoscopic hernia repair using oesophageal Doppler.

Authors:  E J Haxby; M R Gray; C Rodriguez; D Nott; M Springall; M Mythen
Journal:  Br J Anaesth       Date:  1997-05       Impact factor: 9.166

7.  Outcomes analysis of laparoscopic cholecystectomy in the extremely elderly.

Authors:  L M Brunt; M A Quasebarth; D L Dunnegan; N J Soper
Journal:  Surg Endosc       Date:  2001-05-02       Impact factor: 4.584

8.  Hemodynamic changes during laparoscopic cholecystectomy monitored with transesophageal echocardiography.

Authors:  D A Dorsay; F L Greene; C L Baysinger
Journal:  Surg Endosc       Date:  1995-02       Impact factor: 4.584

9.  Pharmacologic intervention can reestablish baseline hemodynamic parameters during laparoscopy.

Authors:  B W Feig; D H Berger; T B Dougherty; J F Dupuis; B Hsi; R C Hickey; D M Ota
Journal:  Surgery       Date:  1994-10       Impact factor: 3.982

10.  Optimization of cardiac preload during laparoscopic donor nephrectomy: a preliminary study of central venous pressure versus esophageal Doppler monitoring.

Authors:  L S Feldman; M Anidjar; P Metrakos; D Stanbridge; G M Fried; F Carli
Journal:  Surg Endosc       Date:  2004-01-14       Impact factor: 4.584

View more
  1 in total

1.  The determination of real fluid requirements in laparoscopic resection of pheochromocytoma using minimally invasive hemodynamic monitoring: a prospectively designed trial.

Authors:  Martin B Niederle; Edith Fleischmann; Barbara Kabon; Bruno Niederle
Journal:  Surg Endosc       Date:  2019-04-11       Impact factor: 4.584

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.