Literature DB >> 16362226

Nitinol Carbofilm coated stents for peripheral applications: study in the porcine model.

M Prunotto1, C Isaia, M A Gatti, E Monari, E Pasquino, M Galloni.   

Abstract

PURPOSE: Testing the safety and foreign body reaction (FBR) of a nitinol self-expandable carbon-coated stent system in the porcine animal model at different follow-up (FU) periods.
METHODS: Fifteen minipigs received 30 carbon-coated self-expandable nitinol stents in iliac arteries. Explants were carried out at 7 (3 animals), 30 (4 animals), 90 (4 animals) and 180 (4 animals) day FU, for evaluation of acute, sub-acute and chronic biological response to the implanted devices. Histological, immunohistochemical, histomorphometric and scanning electron microscopy (SEM) analyses were performed to assess inflammatory reaction, endothelialization process, neointimal growth and cellular composition.
RESULTS: Thirty stents were successfully implanted. No mural thrombi were observed at gross examination or by angiography. Histologically no significant inflammatory reaction was detected: the stents appeared covered by a thin monolayer of endothelial cells even at 7 day FU. The neointima presented homogeneous growth and moderate thickness after 30, 90 and 180 days explants (0.38+/- 0.36 mm, 0.33+/- 0.30 mm, 0.27+/- 0.25 mm respectively). Internal and external elastic laminae were intact in 95% of stented arteries. Histological data validations of vessel endothelialization was obtained with SEM for the seven day follow-up group.
CONCLUSIONS: This study showed good remarkable technical performances, minimal FBR and biocompatibility comparable with other available pre-clinical experimentations.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16362226     DOI: 10.1007/s10856-005-4733-4

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  25 in total

1.  Transluminal expandable nitinol coil stent grafting: preliminary report.

Authors:  C T Dotter; R W Buschmann; M K McKinney; J Rösch
Journal:  Radiology       Date:  1983-04       Impact factor: 11.105

2.  Predictors of diffuse and aggressive intra-stent restenosis.

Authors:  S L Goldberg; A Loussararian; J De Gregorio; C Di Mario; R Albiero; A Colombo
Journal:  J Am Coll Cardiol       Date:  2001-03-15       Impact factor: 24.094

3.  Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.

Authors:  B Thierry; M Tabrizian; C Trepanier; O Savadogo; L Yahia
Journal:  J Biomed Mater Res       Date:  2000-09-15

4.  Effects of nitinol Strecker stent placement on vascular response in normal and stenotic porcine iliac arteries.

Authors:  J J Froelich; H Alfke; A Wilke; A Ramaswamy; K H Barth; M Hoppe; H J Wagner; K J Klose
Journal:  J Vasc Interv Radiol       Date:  1999-03       Impact factor: 3.464

5.  A randomized trial comparing stenting with balloon angioplasty in small vessels in patients with symptomatic coronary artery disease. ISAR-SMART Study Investigators. Intracoronary Stenting or Angioplasty for Restenosis Reduction in Small Arteries.

Authors:  A Kastrati; A Schömig; J Dirschinger; J Mehilli; F Dotzer; N von Welser; F J Neumann
Journal:  Circulation       Date:  2000-11-21       Impact factor: 29.690

6.  Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.

Authors:  G R Dussaillant; G S Mintz; A D Pichard; K M Kent; L F Satler; J J Popma; S C Wong; M B Leon
Journal:  J Am Coll Cardiol       Date:  1995-09       Impact factor: 24.094

7.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

Authors:  D L Fischman; M B Leon; D S Baim; R A Schatz; M P Savage; I Penn; K Detre; L Veltri; D Ricci; M Nobuyoshi
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

8.  Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model.

Authors:  R S Schwartz; K C Huber; J G Murphy; W D Edwards; A R Camrud; R E Vlietstra; D R Holmes
Journal:  J Am Coll Cardiol       Date:  1992-02       Impact factor: 24.094

Review 9.  Drug eluting stents: are human and animal studies comparable?

Authors:  R Virmani; F D Kolodgie; A Farb; A Lafont
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

10.  Carbon-coated stents implanted in porcine iliac and renal arteries: histologic and histomorphometric study.

Authors:  Marco Galloni; Marco Prunotto; Andrea Santarelli; François Laborde; Alain Dibie; Cristina Isaia; Emanuela Monari; Antonietta M Gatti; Enrico Pasquino
Journal:  J Vasc Interv Radiol       Date:  2003-08       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.