Literature DB >> 10855440

Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

A A Polliack1, R C Sieh, D D Craig, S Landsberger, D R McNeil, E Ayyappa.   

Abstract

The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been commercially designed for in situ interface pressure measurement over the past decade. Their use is not common in prosthetic practice, perhaps due to questions of cost effectiveness and the difficulties of interpreting the data. Another concern is the use of sensors for pressure measurements in areas of high contour and complex geometries such as the stump. Before these systems can be used in a clinical setting, it is necessary to determine the reliability and accuracy of each system. In order to assess the clinical validity of the Rincoe SFS and F-Socket systems, a series of trials was conducted to evaluate different aspects of sensor performance, namely; accuracy, hysteresis, drift and the effect of curvature. The sensors were subjected to tests in flatbed and custom-designed pressure vessels. Overall results indicated an accuracy error for the Rincoe SFS system of 25% (flatbed) and 33% (mould), with a corresponding 15% (flatbed) and 23% (mould) error in hysteresis, and 7% (flatbed) and 11% (mould) drift errors. The F-Socket system demonstrated an 8% (flatbed) and 11% (mould) accuracy errors, 42% (flatbed) and 24% (mould) hysteresis errors, and 12% (flatbed) and 33% (mould) drift errors. These findings indicate favourable results for the F-Socket Pressure Measurement System compared to the Rincoe Socket Fitting System with respect to its accuracy errors only. Nevertheless, it is the authors' belief that these systems are adequate in indicating areas of high pressure at the stump socket interface for clinical purposes, but both systems should be used with caution.

Mesh:

Year:  2000        PMID: 10855440     DOI: 10.1080/03093640008726523

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  12 in total

1.  The effect of biomechanical variables on force sensitive resistor error: Implications for calibration and improved accuracy.

Authors:  Jonathon S Schofield; Katherine R Evans; Jacqueline S Hebert; Paul D Marasco; Jason P Carey
Journal:  J Biomech       Date:  2016-02-09       Impact factor: 2.712

2.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

3.  A novel modelling and simulation method of hip joint surface contact stress.

Authors:  Monan Wang; Lei Wang; Pengcheng Li; Yili Fu
Journal:  Bioengineered       Date:  2016-10-03       Impact factor: 3.269

Review 4.  Joint contact stress: a reasonable surrogate for biological processes?

Authors:  Richard A Brand
Journal:  Iowa Orthop J       Date:  2005

5.  Dressings cut to shape alleviate facial tissue loads while using an oxygen mask.

Authors:  Lea Peko Cohen; Zehava Ovadia-Blechman; Oshrit Hoffer; Amit Gefen
Journal:  Int Wound J       Date:  2019-03-05       Impact factor: 3.315

6.  Piezoelectric bimorphs' characteristics as in-socket sensors for transfemoral amputees.

Authors:  Amr M El-Sayed; Nur Azah Hamzaid; Noor Azuan Abu Osman
Journal:  Sensors (Basel)       Date:  2014-12-10       Impact factor: 3.576

7.  Evaluation of Flexible Force Sensors for Pressure Monitoring in Treatment of Chronic Venous Disorders.

Authors:  Suresh Parmar; Iryna Khodasevych; Olga Troynikov
Journal:  Sensors (Basel)       Date:  2017-08-21       Impact factor: 3.576

Review 8.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

Review 9.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

10.  Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

Authors:  Jonathon S Schofield; Katherine R Schoepp; Heather E Williams; Jason P Carey; Paul D Marasco; Jacqueline S Hebert
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.