A novel modelling and simulation method of hip joint surface contact stress.

Monan Wang1, Lei Wang1, Pengcheng Li1, Yili Fu2.   

Abstract

Understanding the hip joint surface contact stress distribution characteristics is helpful to determine hip joint biomechanical features and abnormal pathological behavior. Firstly, a 3-dimensional static hip joint biomechanical model is built using analytical method of model in order to study biomechanical properties including bearing area, stress distribution and the peak value of the contact stress of the femoral head, which reveals the relationship between the biomechanical properties and its geometric parameters. Secondly, based on the finite element analysis of the hip joint model, the contact stress distribution on the surface of femoral head is acquired under the condition of the different joint force and the acetabulum coverage rate. Finally, according to the evaluation of the femoral head surface stress and contact stress peak under different load distribution, accuracy and universality of the biomechanical model is verified.

Keywords:  biomechanical model; finite element analysis; hip joint; surface contact stress

Mesh:

Year:  2016        PMID: 27696938      PMCID: PMC5172508          DOI: 10.1080/21655979.2016.1227630

Source DB:  PubMed          Journal:  Bioengineered        ISSN: 2165-5979            Impact factor:   3.269


  6 in total

1.  Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

Authors:  A A Polliack; R C Sieh; D D Craig; S Landsberger; D R McNeil; E Ayyappa
Journal:  Prosthet Orthot Int       Date:  2000-04       Impact factor: 1.895

2.  Determination of orthotropic bone elastic constants using FEA and modal analysis.

Authors:  W R Taylor; E Roland; H Ploeg; D Hertig; R Klabunde; M D Warner; M C Hobatho; L Rakotomanana; S E Clift
Journal:  J Biomech       Date:  2002-06       Impact factor: 2.712

3.  Relations of mechanical properties to density and CT numbers in human bone.

Authors:  J Y Rho; M C Hobatho; R B Ashman
Journal:  Med Eng Phys       Date:  1995-07       Impact factor: 2.242

4.  Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum. II Instrumented endoprosthesis measurement of articular surface pressure distribution.

Authors:  P D Rushfeldt; R W Mann; W H Harris
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

5.  The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear.

Authors:  T A Maxian; T D Brown; D R Pedersen; J J Callaghan
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

6.  Contact pressures in the human hip joint measured in vivo.

Authors:  W A Hodge; R S Fijan; K L Carlson; R G Burgess; W H Harris; R W Mann
Journal:  Proc Natl Acad Sci U S A       Date:  1986-05       Impact factor: 11.205

  6 in total
  2 in total

1.  Finite element modeling of proximal femur with quantifiable weight-bearing area in standing position.

Authors:  Peng Yang; Tian-Ye Lin; Jing-Li Xu; Hui-Yu Zeng; Da Chen; Bing-Lang Xiong; Feng-Xiang Pang; Zhen-Qiu Chen; Wei He; Qiu-Shi Wei; Qing-Wen Zhang
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

2.  The roof step cut: A novel technique for bony reconstruction of acetabular roof deficiency during total hip replacement.

Authors:  Zoltán Csernátony; Gyula Győrfi; Sándor Barna; Sándor Manó; János Szabó; Lei Zhang
Journal:  Jt Dis Relat Surg       Date:  2022-03-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.