Literature DB >> 10840435

Detrusor pressure uroflowmetry studies in women: effect of a 7Fr transurethral catheter.

A Groutz1, J G Blaivas, A M Sassone.   

Abstract

PURPOSE: We evaluated whether a 7Fr transurethral catheter affects urinary flow in women undergoing pressure flow studies for voiding symptoms.
MATERIALS AND METHODS: We reviewed a urodynamic database of 600 consecutive women referred for the evaluation of voiding symptoms. Before urodynamics all patients voided privately using a standard toilet and free flow was recorded. Urodynamics were performed using a 7Fr double lumen transurethral catheter. At functional bladder capacity patients were asked to void in the sitting position and pressure flow studies were performed. All uroflowmetry tracings were inspected and analyzed manually. Only patients who voided similar volumes varying by less than 20% on the free and pressure flow studies were assessed. Free and pressure flow parameters were compared according to voided volume category, main urodynamic diagnosis, uroflowmetry pattern and pre-void bladder volume.
RESULTS: A similar volume was voided on the free and pressure flow studies of 100 women. In each voided volume category and urodynamic diagnosis pressure flow parameters were significantly different from the equivalent free flow parameters in all but 4 cases. Specifically the maximum flow rate was significantly less and flow time was significantly longer on pressure versus free flow studies (each p <0.01). An intermittent flow pattern was more common on pressure than in free flow measurements (43% versus 9%).
CONCLUSIONS: A 7Fr transurethral catheter may adversely affect uroflowmetry parameters in women undergoing pressure flow studies for lower urinary tract symptoms. This finding may have further clinical implications regarding the interpretation of these parameters as well as establishment of an accurate diagnosis.

Entities:  

Mesh:

Year:  2000        PMID: 10840435

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  11 in total

1.  Decreased maximum flow rate during intubated flow is not only due to urethral catheter in situ.

Authors:  Françoise A Valentini; Gilberte Robain; Dorothée S Hennebelle; Pierre P Nelson
Journal:  Int Urogynecol J       Date:  2012-06-22       Impact factor: 2.894

2.  What is the relationship between free flow and pressure flow studies in women?

Authors:  Jonathan Duckett; Katherine Cheema; Avanti Patil; Maya Basu; Sian Beale; Brian Wise
Journal:  Int Urogynecol J       Date:  2012-07-20       Impact factor: 2.894

3.  Evidence of a functional effect of transient transurethral catheterization on micturition in women.

Authors:  Anne M Suskind; Phillip P Smith
Journal:  Int Urogynecol J       Date:  2012-01-17       Impact factor: 2.894

Review 4.  When are urodynamics indicated in patients with stress urinary incontinence?

Authors:  Benjamin E Dillon; Philippe E Zimmern
Journal:  Curr Urol Rep       Date:  2012-10       Impact factor: 3.092

5.  The effect of a 6 Fr catheter in women: Are they obstructive?

Authors:  Patrick Richard; Nydia Icaza Ordonez; Le Mai Tu
Journal:  Can Urol Assoc J       Date:  2013 May-Jun       Impact factor: 1.862

Review 6.  The influence of intubation on urinary flow parameters in pressure-flow study and its significance for urodynamic diagnosis.

Authors:  Yu Cheng; Shengfei Xu; Jiang Chen; Xiaoyu Wu; Zhong Chen; Guanghui Du
Journal:  Int Urogynecol J       Date:  2022-01-27       Impact factor: 1.932

Review 7.  Current concepts and controversies in urodynamics.

Authors:  C E Kelly; R J Krane
Journal:  Curr Urol Rep       Date:  2000-10       Impact factor: 2.862

Review 8.  A comparison of external transducers and microtransducers in urodynamic studies of female patients.

Authors:  Peter M Lotze
Journal:  Curr Urol Rep       Date:  2005-09       Impact factor: 2.862

9.  Correlation between voiding dysfunction symptoms and uroflowmetry in women suffering from stress urinary incontinence.

Authors:  Katelyne Hubeaux; Xavier Deffieux; Marylène Jousse; Gérard Amarenco
Journal:  Indian J Urol       Date:  2012-07

10.  A comparison of normal and high post-void residual urine and urodynamic parameters in women with overactive bladder.

Authors:  Hediye Dağdeviren; Hüseyin Cengiz; Çağlar Helvacıoğlu; Ulkar Heydarova; Cihan Kaya; Murat Ekin
Journal:  Turk J Obstet Gynecol       Date:  2017-12-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.