Literature DB >> 10832983

Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length.

M Hosny1, J L Alio, P Claramonte, W H Attia, J J Perez-Santonja.   

Abstract

PURPOSE: Phakic intraocular lenses are being used increasingly to correct refractive errors. We studied the relationship between anterior chamber depth, refractive state of the eye, spherical equivalent refraction, axial length of the globe, corneal diameter, and keratometry.
METHODS: Two hundred eleven eyes of 211 patients were enrolled. All eyes underwent the same protocol with a complete ocular examination that included slit-lamp microscopy, intraocular pressure, objective and subjective refraction, calculation of the spherical equivalent refraction, corneal pachymetry, anterior chamber depth, axial length of the globe, and keratometry. All results were analyzed statistically using SPSS statistics software. Correlations between different parameters were studied using the Pearson correlation test.
RESULTS: The anterior chamber depth was found to correlate significantly with both the average corneal diameter and the axial length of the globe (0.744, 0.531, P < .01) and was also found to correlate through an inverse relation with both age and spherical equivalent refraction (-0.391, -0.623, P < .01). Corneal thickness and keratometric power did not correlate with the anterior chamber depth.
CONCLUSION: Most parameters (axial length, corneal diameter, spherical equivalent refraction, patient age) affected anterior chamber depth and should be considered carefully when planning refractive procedures that employ phakic intraocular lenses.

Entities:  

Mesh:

Year:  2000        PMID: 10832983     DOI: 10.3928/1081-597X-20000501-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  17 in total

1.  Characteristics of higher-order aberrations and anterior segment tomography in patients with pathologic myopia.

Authors:  Kaori Kasahara; Naoyuki Maeda; Takashi Fujikado; Makoto Tomita; Muka Moriyama; Mutsumi Fuchihata; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2016-11-28       Impact factor: 2.031

2.  Keratometry with five different techniques: a study of device repeatability and inter-device agreement.

Authors:  Shiva Mehravaran; Soheila Asgari; Sara Bigdeli; Ashkan Shahnazi; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2014-02-23       Impact factor: 2.031

3.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

4.  The eye of the laboratory mouse remains anatomically adapted for natural conditions.

Authors:  Jonathan M Shupe; Deborah M Kristan; Steven N Austad; Deborah L Stenkamp
Journal:  Brain Behav Evol       Date:  2005-10-10       Impact factor: 1.808

5.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

6.  Does anisometropia affect the ciliary muscle thickness? An ultrasound biomicroscopy study.

Authors:  Selim Cevher; Tayfun Şahin
Journal:  Int Ophthalmol       Date:  2020-10-20       Impact factor: 2.031

7.  The Association of Refractive Error with Glaucoma in a Multiethnic Population.

Authors:  Ling Shen; Ronald B Melles; Ravikanth Metlapally; Lisa Barcellos; Catherine Schaefer; Neil Risch; Lisa J Herrinton; Christine Wildsoet; Eric Jorgenson
Journal:  Ophthalmology       Date:  2015-08-08       Impact factor: 12.079

8.  Differences in ocular dimensions between normal and dry eyes.

Authors:  Juan A Sanchis-Gimeno; Manuel Herrera; Franzisco Sánchez-del-Campo; Francisco Martínez-Soriano
Journal:  Surg Radiol Anat       Date:  2006-02-15       Impact factor: 1.246

9.  Relationships between central and peripheral corneal thickness in different degrees of myopia.

Authors:  Sara Ortiz; Laura Mena; Ana Rio-San Cristobal; Raul Martin
Journal:  J Optom       Date:  2013-05-16

10.  Comparison of anterior segment optical tomography parameters measured using a semi-automatic software to standard clinical instruments.

Authors:  Marcus Ang; Wesley Chong; Huiqi Huang; Wan Ting Tay; Tien Yin Wong; Ming-Guang He; Tin Aung; Jodhbir S Mehta
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.