Literature DB >> 765317

Measurement of cardiac output by electrical impedance at rest and during exercise.

J C Denniston, J T Maher, J T Reeves, J C Cruz, A Cymerman, R F Grover.   

Abstract

A comparison was made between cardiac output values determined by the dye dilution and electrical impedance methods in ten subjects at rest and during graded exercise on a bicycle ergometer. The cardiac output values determined by the two methods were linearly related and significantly (P less than 0.001) correlated (r = 0.90). Movement artifact associated with exercise at maximum or near-maximum work loads caused severe distortion of the dZ/dt wave form and prevented calculation of impedance cardiac output at these levels of work. Use of the lowest value of L (distance between mean value of L in the impedance stroke volume equation (SV = p(L2/ZO2) (dZ/dt)mt), resulted in nearly identical values for the least-squares line and equalvalue line of impedance and dye cardiac outputs. Although absolute values of cardiac output determined by the two methods were not identical in all subjects the changes in cardiac output were nearly identical during the different levels of exercise. The data support the validity of the impedance method as a noninvasive, atraumatic measure of cardiac output at rest and during graded exercise.

Entities:  

Mesh:

Year:  1976        PMID: 765317     DOI: 10.1152/jappl.1976.40.1.91

Source DB:  PubMed          Journal:  J Appl Physiol        ISSN: 0021-8987            Impact factor:   3.531


  53 in total

1.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

2.  The cardiovascular effects of oral nifedipine and nicardipine: a double-blind comparison in healthy volunteers using transthoracic bioimpedance cardiography.

Authors:  S H Thomas; P Molyneux; J Kelly; S E Smith
Journal:  Eur J Clin Pharmacol       Date:  1990       Impact factor: 2.953

3.  Application of bioreactance for cardiac output assessment during exercise in healthy individuals.

Authors:  Adrian Elliott; James H Hull; David Nunan; Djordje G Jakovljevic; David Brodie; Lesley Ansley
Journal:  Eur J Appl Physiol       Date:  2010-03-25       Impact factor: 3.078

4.  Respiratory effects on cardiac related impedance indices measured under voluntary cardio-respiratory synchronisation (VCRS).

Authors:  L Wang; R P Patterson; S B Raza
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

5.  Evaluation of the theory of cardiac-output computation from transthoracic impedance plethysmogram.

Authors:  K Yamakoshi; T Togawa; H Ito
Journal:  Med Biol Eng Comput       Date:  1977-09       Impact factor: 2.602

6.  Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal.

Authors:  S B Raza; R P Patterson; L Wang
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

7.  Mapping the cardiogenic impedance signal on the thoracic surface.

Authors:  R P Patterson; L Wang; B Raza; K Wood
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

8.  Multi-channel electrical bioimpedance: a new noninvasive method to simultaneously measure cardiac and peripheral blood flow.

Authors:  Alfred W H Stanley; Jeffery W Herald; Constantine L Athanasuleas; Saji C Jacob; Scott W Sims; Alfred A Bartolucci; Alexander N Tsoglin
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

9.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

10.  The effect of a progressive decrease in the circulating blood volume of the dog on the transthoracic impedance.

Authors:  D W Hill; S N Mohapatra; K C Welham; M L Stevenson
Journal:  Eur J Intensive Care Med       Date:  1976-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.