Calibration of position and angular data from a magnetic tracking device.

J S Day1, D J Murdoch, G A Dumas.   

Abstract

This paper describes a method for calibrating data from a magnetic tracking device. Position and orientation data were collected in a 1. 6x0.8x1.4m(3) volume using a Polhemus Fastrak((R)) in conjunction with both a long-range and standard transmitter. Position and orientation data were calibrated using a locally linear model based on the position of the measurement. After calibration, the average position and angular errors were less than 1.8cm and 1.2 degrees up to 1.8m from the transmitter for the long-range transmitter. For the standard transmitter, even after calibration, errors increased sharply when the sensor was more than 1.2m from the transmitter. Up to that distance, post-calibration errors were less than 1.2cm and 1. 2 degrees, while up to 1.8m they were below 5cm and 4 degrees. These errors could be further reduced by noise filtering. However, use of the standard transmitter is not recommended at distance greater than 1.2m due to orientation-based effects. It was concluded that for the volume investigated, tracking devices could provide similar three-dimensional accuracy to video systems.

Entities:  

Mesh:

Year:  2000        PMID: 10828336     DOI: 10.1016/s0021-9290(00)00044-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  In vitro validation and reliability study of electromagnetic skin sensors for evaluation of end range of motion positions of the hip.

Authors:  E A Audenaert; L Vigneron; T Van Hoof; K D'Herde; G van Maele; D Oosterlinck; C Pattyn
Journal:  Med Biol Eng Comput       Date:  2011-07-13       Impact factor: 2.602

2.  Relationship between gluteal muscle activation and upper extremity kinematics and kinetics in softball position players.

Authors:  Gretchen D Oliver
Journal:  Med Biol Eng Comput       Date:  2013-03-22       Impact factor: 2.602

3.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

4.  Kinematic evaluation of the modified Weaver-Dunn acromioclavicular joint reconstruction.

Authors:  Robert F LaPrade; Daren J Wickum; Chad J Griffith; Paula M Ludewig
Journal:  Am J Sports Med       Date:  2008-06-06       Impact factor: 6.202

5.  Chiropractic and self-care for back-related leg pain: design of a randomized clinical trial.

Authors:  Craig A Schulz; Maria A Hondras; Roni L Evans; Maruti R Gudavalli; Cynthia R Long; Edward F Owens; David G Wilder; Gert Bronfort
Journal:  Chiropr Man Therap       Date:  2011-03-22

Review 6.  Gait analysis using wearable sensors.

Authors:  Weijun Tao; Tao Liu; Rencheng Zheng; Hutian Feng
Journal:  Sensors (Basel)       Date:  2012-02-16       Impact factor: 3.576

7.  Association of Upper Extremity Pain With Softball Pitching Kinematics and Kinetics.

Authors:  Gretchen D Oliver; Kenzie Friesen; Jeff W Barfield; Kevin Giordano; Adam Anz; Jeff Dugas; James Andrews
Journal:  Orthop J Sports Med       Date:  2019-08-21

8.  Impact Analysis of Basketball Exercise Strength Based on Machine Learning in the Mental Health of College Students.

Authors:  Ran Zhang
Journal:  Comput Intell Neurosci       Date:  2022-09-27

9.  Reliability and validity of spinal coordination patterns during treadmill walking in persons with thoracic spine pain--a preliminary study.

Authors:  Jean Wessel; Michael R Pierrynowski; Kelly Pennell; Linda J Woodhouse
Journal:  BMC Musculoskelet Disord       Date:  2013-12-09       Impact factor: 2.362

10.  Scapula Kinematics of Youth Baseball Players.

Authors:  Gretchen Oliver; Wendi Weimar
Journal:  J Hum Kinet       Date:  2015-12-30       Impact factor: 2.193

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.