A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery.

Faria-Inocencio Ana1, Gallas-Torreira Mercedes.   

Abstract

PURPOSE: This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery.
MATERIALS AND METHODS: A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point.
RESULTS: This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs.
CONCLUSION: This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

Entities:  

Keywords:  Alveolar Bone Loss; Molar, Third; Periodontal Attachment Loss; Radiography, Dental

Year:  2011        PMID: 22010068      PMCID: PMC3189535          DOI: 10.5624/isd.2011.41.3.115

Source DB:  PubMed          Journal:  Imaging Sci Dent        ISSN: 2233-7822


  22 in total

Review 1.  Radiographic and digital imaging in periodontal practice.

Authors:  E Hausmann
Journal:  J Periodontol       Date:  2000-03       Impact factor: 6.993

2.  Effect of x-ray beam vertical angulation on radiographic alveolar crest level measurement.

Authors:  E Hausmann; K Allen; L Christersson; R J Genco
Journal:  J Periodontal Res       Date:  1989-01       Impact factor: 4.419

3.  What alveolar crest level on a bite-wing radiograph represents bone loss?

Authors:  E Hausmann; K Allen; V Clerehugh
Journal:  J Periodontol       Date:  1991-09       Impact factor: 6.993

Review 4.  A review of the reliability of radiographic measurements in estimating alveolar bone changes.

Authors:  D K Benn
Journal:  J Clin Periodontol       Date:  1990-01       Impact factor: 8.728

5.  Reproducibility of bone height measurements made on serial radiographs.

Authors:  E Hausmann; K Allen
Journal:  J Periodontol       Date:  1997-09       Impact factor: 6.993

6.  Periodontal healing after impacted lower third molar surgery. Precision and accuracy of radiographic assessment of intrabony defects.

Authors:  C F Kugelberg; U Ahlström; S Ericson; A Hugoson
Journal:  Int J Oral Maxillofac Surg       Date:  1986-12       Impact factor: 2.789

7.  Radiographic assessment of periodontal disease.

Authors:  H Björn
Journal:  Int Dent J       Date:  1968-09       Impact factor: 2.512

8.  Radiographic amelocemental junction and alveolar crest: effect of X-ray beam angulation.

Authors:  S M Jenkins; P M Dummer; R G Newcombe
Journal:  J Oral Rehabil       Date:  1995-09       Impact factor: 3.837

9.  Detection of experimentally induced lesions in subtraction images of cancellous alveolar bone.

Authors:  J W Katsarsky; M S Levine; K M Allen; E Hausmann
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1994-06

10.  Relationship between alveolar bone measured by 125I absorptiometry with analysis of standardized radiographs: 2. Bjorn technique.

Authors:  L F Ortman; K McHenry; E Hausmann
Journal:  J Periodontol       Date:  1982-05       Impact factor: 6.993

View more
  4 in total

1.  Repeatability and accuracy of a paralleling technique for radiographic evaluation of distal bone healing after impacted third molar surgery.

Authors:  A Inocêncio Faria; M Gallas Torreira; M López Ratón
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

2.  The "Red Line" Conundrum: A Concept Beyond Its Expiry Date?

Authors:  Sanjeev Kumar; Mahendra P Reddy; Lokesh Chandra; Alok Bhatnagar
Journal:  J Maxillofac Oral Surg       Date:  2013-08-02

3.  Effectiveness of a personalized device in the evaluation of mandibular second molar periodontal healing after surgical extraction of adjacent third molar.

Authors:  Roberto Pippi
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

4.  Impact of the presence of partially erupted third molars on the local radiographic bone condition.

Authors:  Ighor Andrade Fernandes; Endi Lanza Galvão; Patricia Furtado Gonçalves; Saulo Gabriel Moreira Falci
Journal:  Sci Rep       Date:  2022-05-23       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.