Literature DB >> 10766079

The anatomic variability of human cervical pedicles: considerations for transpedicular screw fixation in the middle and lower cervical spine.

E K Shin1, M M Panjabi, N C Chen, J L Wang.   

Abstract

Transpedicular screw fixation has recently been shown to be successful in stabilizing the middle and lower cervical spine. Controversy exists, however, over its efficacy, due to the smaller size of cervical pedicles and the proximity of significant neurovascular structures to both lateral and medial cortical walls. To aid the spinal surgeon in the insertion of pedicle screws, a number of studies have been performed to quantify the gross dimensions and angulations of the cervical pedicle. Notwithstanding these quantitative studies, there has been a conspicuous absence of research reporting the qualitative characteristics of the cervical pedicle. The purpose of our study was to provide comparative graphical data that would systematically document the anatomic variability in cervical pedicle morphology. Such information should better elucidate the complexity of the pedicle as a three-dimensional structure and provide the spinal surgeon with a more complete understanding of cervical pedicle architecture. Twenty-six human cervical vertebrae (C3-C7) from six fresh-frozen spines were secured to a thin sectioning apparatus to produce three 0.7-mm-thick pedicle slices along its axis. Radiographs taken of these pedicle slices were scanned, digitized, and traced to facilitate visual comparison. The pedicle slices were found to exhibit substantial variability in composition and shape, not only between individual spines and vertebral levels, but also within the pedicle axis. However, the lateral cortex was consistently found to be thinner than the medial cortex in all samples. These physical findings must be noted by surgeons attempting transpedicular screw fixation in the cervical spine.

Entities:  

Mesh:

Year:  2000        PMID: 10766079      PMCID: PMC3611356          DOI: 10.1007/s005860050011

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  18 in total

1.  C7 posterior fixation using intralaminar screws : early clinical and radiographic outcome.

Authors:  Sang Hoon Jang; Jae Taek Hong; Il Sup Kim; In Sung Yeo; Byung Chul Son; Sang Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2010-08-31

2.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

3.  CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Authors:  Zhu Ruofu; Yang Huilin; Hu Xiaoyun; He Xishun; Tang Tiansi; Chen Liang; Li Xigong
Journal:  Surg Radiol Anat       Date:  2008-03-20       Impact factor: 1.246

Review 4.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

5.  The ipsilateral lamina-pedicle angle: can it be used to guide pedicle screw placement in the sub-axial cervical spine?

Authors:  Edward Bayley; Zergham Zia; Robert Kerslake; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-09-01       Impact factor: 3.134

6.  Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.

Authors:  Dong-Ho Lee; Sung-Woo Lee; Suk Jung Kang; Chang Ju Hwang; Nam Heun Kim; Ju-Yul Bae; Yung-Tae Kim; Choon Sung Lee; K Daniel Riew
Journal:  Eur Spine J       Date:  2011-04-09       Impact factor: 3.134

7.  A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws.

Authors:  Yoshihiro Hojo; Manabu Ito; Kota Suda; Itaru Oda; Hisashi Yoshimoto; Kuniyoshi Abumi
Journal:  Eur Spine J       Date:  2014-07-22       Impact factor: 3.134

8.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

9.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

10.  Intra-osseous ultrasound for pedicle screw positioning in the subaxial cervical spine: an experimental study.

Authors:  Sven Rainer Kantelhardt; Hans Christoph Bock; Laila Siam; Jörg Larsen; Ralf Burger; Wolfgang Schillinger; Volker Bockermann; Veit Rohde; Alf Giese
Journal:  Acta Neurochir (Wien)       Date:  2009-07-14       Impact factor: 2.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.