Literature DB >> 10752817

Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization.

E Barin1, D G Haryadi, S I Schookin, D R Westenskow, V G Zubenko, K R Beliaev, A A Morozov.   

Abstract

OBJECTIVE: To evaluate the accuracy and precision of an advanced thoracic bioimpedance cardiac output monitor by comparing it with conventional thermodilution.
DESIGN: Prospective data collected from 47 patients undergoing routine cardiac catheterization. The new bioimpedance system differs from its predecessors in electrode system configuration, advanced signal processing, use of a modified Kubicek equation, and a reliable estimate of left ventricular ejection time from the time derivative bioimpedance signals.
SETTING: A cardiac catheterization laboratory in a university affiliated teaching hospital. PATIENTS: A series of 47 relatively homogenous patients undergoing routine cardiac catheterization for suspected cardiac disease.
MEASUREMENTS AND MAIN RESULTS: The data from the first 20 patients was used to determine optimal values for coefficients in the bioimpedance cardiac output equations. The coefficients found were used when the system was tested in the subsequent 27 patients. For the last 27 patients, a total of 80 simultaneous pairs of cardiac output measurements were made by conventional thermodilution and by thoracic bioimpedance. The mean difference between the two methods was -0.31 L/min and the standard deviation of the differences was (0.76 L/min). The correlation coefficient was r2 = .72 (p < .001).
CONCLUSIONS: The correlation between conventional thermodilution and thoracic bioimpedance cardiac output estimates was good and the standard deviation of the differences was lower than that reported for commercially available devices. The system can be used in the cardiac catheterization lab for reliable and continuous noninvasive measurement of cardiac output.

Entities:  

Mesh:

Year:  2000        PMID: 10752817     DOI: 10.1097/00003246-200003000-00016

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  17 in total

1.  Averaging improves the quality of impedance stroke volume measurements during the head up tilt test.

Authors:  Ye Zhang; Lester A H Critchley; Julian A J H Critchley
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

2.  Evaluation of a new advanced thoracic bioimpedance device for estimation of cardiac output.

Authors:  D G Haryadi; D R Westenskow; L A Critchley; S I Schookin; V G Zubenko; K R Beliaev; A A Morozov
Journal:  J Clin Monit Comput       Date:  1999-02       Impact factor: 2.502

3.  Evaluation of impedance based indices of cardiac contractility in dogs.

Authors:  Zhi-yong Peng; Lester A H Critchley; Benny S P Fok; Anthony E James
Journal:  J Clin Monit Comput       Date:  2004-04       Impact factor: 2.502

4.  Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method.

Authors:  Arunodaya R Gujjar; K Muralidhar; Sanjay Banakal; Ratan Gupta; Talakad N Sathyaprabha; P S Jairaj
Journal:  J Clin Monit Comput       Date:  2008-04-17       Impact factor: 2.502

5.  Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter.

Authors:  Bouchra Lamia; Hyung Kook Kim; Donald A Severyn; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2017-02-10       Impact factor: 2.502

6.  Value of impedance cardiography in patients studied for pulmonary hypertension.

Authors:  Adriano R Tonelli; Hassan Alnuaimat; Ning Li; Robin Carrie; Kamal K Mubarak
Journal:  Lung       Date:  2011-05-24       Impact factor: 2.584

7.  [Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations].

Authors:  M Bock; T Sturm; J Motsch
Journal:  Anaesthesist       Date:  2007-07       Impact factor: 1.041

8.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

9.  Noninvasive cardiac output monitoring (NICOM): a clinical validation.

Authors:  Pierre Squara; Dominique Denjean; Philippe Estagnasie; Alain Brusset; Jean Claude Dib; Claude Dubois
Journal:  Intensive Care Med       Date:  2007-04-26       Impact factor: 17.440

10.  Haemodynamic changes during craniotomy monitored by a bioimpedance plethysmographic noninvasive cardiac output monitor.

Authors:  Zulfiqar Ali; G S Umamaheswara Rao; A Jaganath
Journal:  J Clin Monit Comput       Date:  2009-02-11       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.