Literature DB >> 21604215

Value of impedance cardiography in patients studied for pulmonary hypertension.

Adriano R Tonelli1, Hassan Alnuaimat, Ning Li, Robin Carrie, Kamal K Mubarak.   

Abstract

The aim of this study was to evaluate the accuracy and precision of impedance cardiography as a method for noninvasive hemodynamic evaluation of patients with pulmonary hypertension (PH). We performed a prospective and blinded study of patients who underwent right heart catheterization (RHC) for evaluation of known or presumed PH at the University of Florida from August 2009 to March 2010. The cohort consisted of a total of 39 patients (age = 57 ± 14 years, 87% women) with presumed (23%) or confirmed PH (77%) of different etiologies. Patients underwent RHC and impedance cardiography using the PhysioFlow PF-05. The PhysioFlow PF-05 measures cardiac output (CO) and LV end-diastolic volume (LVEDV), among other parameters. The median pulmonary artery pressure was 36 (IQR 26-56) mmHg. The CO (mean ± SD) by thermodilution (CO-T) and by impedance cardiography (CO-IC) was 5.9 ± 2.2 and 5.6 ± 1.5 L/min, respectively. Bland-Altman analysis of CO-T versus CO-IC revealed a mean of 0.3 L/min (95% LoA: -2.2 to +2.8). In patients with PH, the correlation of CO-T and CO-IC had a mean of 0.4 L/min (95% LoA: 2.9 and -2.2). Pulmonary artery occlusion pressure (PAOP) correlated with LVEDV (R (2) = 0.2, p = 0.005). By ROC analysis, EDV ≥ 200 ml had a sensitivity of 53% and a specificity of 86% for PAOP > 15 mmHg (AUC = 0.78). In patients with PH, impedance cardiography had good accuracy and fair precision for CO determination when compared with thermodilution. Impedance cardiography may provide information about the preload status and has the potential to become a cost-effective and noninvasive method for the follow-up of patients with PH.

Entities:  

Mesh:

Year:  2011        PMID: 21604215     DOI: 10.1007/s00408-011-9299-y

Source DB:  PubMed          Journal:  Lung        ISSN: 0341-2040            Impact factor:   2.584


  31 in total

1.  A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the "direct" Fick method.

Authors:  A Charloux; E Lonsdorfer-Wolf; R Richard; E Lampert; M Oswald-Mammosser; B Mettauer; B Geny; J Lonsdorfer
Journal:  Eur J Appl Physiol       Date:  2000-07       Impact factor: 3.078

2.  The validity of cardiac output measurement by thoracic impedance: a meta-analysis.

Authors:  H D Fuller
Journal:  Clin Invest Med       Date:  1992-04       Impact factor: 0.825

3.  Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure.

Authors:  Nancy M Albert; Melanie D Hail; Jianbo Li; James B Young
Journal:  Am J Crit Care       Date:  2004-11       Impact factor: 2.228

4.  Sildenafil improves cardiac output and exercise performance during acute hypoxia, but not normoxia.

Authors:  Andrew R Hsu; Kimberly E Barnholt; Nicolas K Grundmann; Joseph H Lin; Stewart W McCallum; Anne L Friedlander
Journal:  J Appl Physiol (1985)       Date:  2006-02-02

Review 5.  Ambulatory impedance cardiography: a systematic review.

Authors:  Monica J E Parry; Judith McFetridge-Durdle
Journal:  Nurs Res       Date:  2006 Jul-Aug       Impact factor: 2.381

6.  Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: the BioImpedance CardioGraphy (BIG) substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) Trial.

Authors:  Sandeep A Kamath; Mark H Drazner; Gudaye Tasissa; Joseph G Rogers; Lynne Warner Stevenson; Clyde W Yancy
Journal:  Am Heart J       Date:  2009-08       Impact factor: 4.749

Review 7.  Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography.

Authors:  Richard L Summers; William C Shoemaker; W Franklin Peacock; Douglas S Ander; Thomas G Coleman
Journal:  Acad Emerg Med       Date:  2003-06       Impact factor: 3.451

Review 8.  Impedance cardiography: a rapid and cost-effective screening tool for cardiac disease.

Authors:  Jean Bour; John Kellett
Journal:  Eur J Intern Med       Date:  2008-02-11       Impact factor: 4.487

Review 9.  Outpatient cardiovascular management utilizing impedance cardiography.

Authors:  Marie Lasater; Kathryn Truter Von Rueden
Journal:  AACN Clin Issues       Date:  2003-05

10.  Impedance cardiography: A valuable method of evaluating haemodynamic parameters.

Authors:  Tomasz Sodolski; Andrzej Kutarski
Journal:  Cardiol J       Date:  2007       Impact factor: 2.737

View more
  14 in total

1.  Hemodynamic adjustments during breath-holding in trained divers.

Authors:  Guillaume Costalat; Jeremy Coquart; Ingrid Castres; Claire Tourny; Frederic Lemaitre
Journal:  Eur J Appl Physiol       Date:  2013-07-03       Impact factor: 3.078

2.  Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair.

Authors:  Antoine Legendre; D Bonnet; L Bosquet
Journal:  Pediatr Cardiol       Date:  2017-09-25       Impact factor: 1.655

3.  Value of impedance cardiography during 6-minute walk test in pulmonary hypertension.

Authors:  Adriano R Tonelli; Laith Alkukhun; Vineesha Arelli; José Ramos; Jennie Newman; Kevin McCarthy; Bohdan Pichurko; Omar A Minai; Raed A Dweik
Journal:  Clin Transl Sci       Date:  2013-09-06       Impact factor: 4.689

4.  Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography.

Authors:  Alicia Gonzalez-Represas; Laurent Mourot
Journal:  Int J Cardiovasc Imaging       Date:  2019-12-16       Impact factor: 2.357

5.  Mixed Venous Oxygen Saturation Is a Better Prognosticator Than Cardiac Index in Pulmonary Arterial Hypertension.

Authors:  Ghaleb Khirfan; Allaa Almoushref; Tawfeq Naal; Batool Abuhalimeh; Raed A Dweik; Gustavo A Heresi; Adriano R Tonelli
Journal:  Chest       Date:  2020-07-03       Impact factor: 9.410

6.  Skeletal muscle reoxygenation after high-intensity exercise in mitochondrial myopathy.

Authors:  Daniela M Bravo; Ana Cristina Gimenes; Rúbia B Nascimento; Eloara V M Ferreira; Ana Cristina B Siqueira; Ethiane D S Meda; J Alberto Neder; Luiz Eduardo Nery
Journal:  Eur J Appl Physiol       Date:  2011-09-04       Impact factor: 3.078

7.  Non-Invasive Cardiac Output Determination Using Magnetic Resonance Imaging and Thermodilution in Pulmonary Hypertension.

Authors:  Lindsey A Crowe; Léon Genecand; Anne-Lise Hachulla; Stéphane Noble; Maurice Beghetti; Jean-Paul Vallée; Frédéric Lador
Journal:  J Clin Med       Date:  2022-05-11       Impact factor: 4.964

8.  Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease.

Authors:  Mohammed Ebrahim; Sanjeet Hegde; Beth Printz; Mark Abcede; James A Proudfoot; Christopher Davis
Journal:  Pediatr Cardiol       Date:  2016-08-25       Impact factor: 1.655

9.  Heart rate slopes during 6-min walk test in pulmonary arterial hypertension, other lung diseases, and healthy controls.

Authors:  Adriano R Tonelli; Xiao-Feng Wang; Laith Alkukhun; Qi Zhang; Raed A Dweik; Omar A Minai
Journal:  Physiol Rep       Date:  2014-06-11

10.  Cardiac hemodynamic response to the 6-minute walk test in young adults and the elderly.

Authors:  Fujiko Someya; Naoki Mugii; Sachie Oohata
Journal:  BMC Res Notes       Date:  2015-08-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.