Literature DB >> 12748810

Urgent thoracic aortal dissection and aneurysm: treatment with stent-graft implantation in an angiographic suite.

Jörn O Balzer1, Mirko Doss, Axel Thalhammer, Hans-Gerd Fieguth, Anton Moritz, Thomas J Vogl.   

Abstract

The aim of this study was to evaluate the feasibility of endoluminal stent-graft placement in an angiographic suite for the treatment of emergent type-B aortic dissections and ruptured thoracic aortal aneurysms. Twenty-six patients with either urgent type-B dissection (n=8) or aneurysms (n=18) of the descending thoracic aorta were chosen for stent-graft implantation. All patients received a multidetector-row CT angiography of the whole aorta and pelvic arteries prior to stent-graft implantation. All procedures were performed in a fully equipped digital subtraction angiography (DSA) suite under general anesthesia. In 20 patients Talent LPS tube grafts and in 4 patients an Excluder graft were used. Access was achieved via surgical cut-down in the left (n=7) or right (n=19) groin. Sealing was successful in 24 patients. The proximal covered portion of the stent graft was placed across the left subclavian artery in 2 patients. Procedural success was achieved in 23 of 24 patients. One patient required a second stent-graft placement before the aneurysm was sealed. One patient with an acute perforation of the descending aorta died due to cardiac failure prior to stent-graft implantation. In 1 patient stent-graft delivery failed due to severe calcification of both common iliac arteries. Endoluminal treatment of both urgent type-B aortic dissections and thoracic aortal aneurysms with stent graft is an attractive alternative treatment to surgical repair. The placement of stent grafts in an angiographic suite is a safe and feasible method with good clinical effectiveness and, so far, good clinical outcome.

Entities:  

Mesh:

Year:  2003        PMID: 12748810     DOI: 10.1007/s00330-003-1921-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

1.  Endovascular stent-graft placement for the treatment of acute aortic dissection.

Authors:  M D Dake; N Kato; R S Mitchell; C P Semba; M K Razavi; T Shimono; T Hirano; K Takeda; I Yada; D C Miller
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

2.  Changes in aneurysm morphology and stent-graft configuration after endovascular repair of aneurysms of the descending thoracic aorta.

Authors:  T Resch; B Koul; N V Dias; B Lindblad; K Ivancev
Journal:  J Thorac Cardiovasc Surg       Date:  2001-07       Impact factor: 5.209

3.  Cerebrospinal fluid drainage to reverse paraplegia after endovascular thoracic aortic aneurysm repair.

Authors:  K Tiesenhausen; W Amann; G Koch; K A Hausegger; P Oberwalder; B Rigler
Journal:  J Endovasc Ther       Date:  2000-04       Impact factor: 3.487

4.  Thoracic and thoracoabdominal aortic aneurysm repair using cardiopulmonary bypass, profound hypothermia, and circulatory arrest via left side of the chest incision.

Authors:  H J Safi; C C Miller; M H Subramaniam; M P Campbell; D C Iliopoulos; J J O'Donnell; M J Reardon; G V Letsou; R Espada
Journal:  J Vasc Surg       Date:  1998-10       Impact factor: 4.268

5.  Natural history of descending thoracic and thoracoabdominal aneurysms.

Authors:  R B Griepp; M A Ergin; J D Galla; S L Lansman; J N McCullough; K H Nguyen; J J Klein; D Spielvogel
Journal:  Ann Thorac Surg       Date:  1999-06       Impact factor: 4.330

6.  Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts.

Authors:  M Grabenwöger; D Hutschala; M P Ehrlich; F Cartes-Zumelzu; S Thurnher; J Lammer; E Wolner; M Havel
Journal:  Ann Thorac Surg       Date:  2000-02       Impact factor: 4.330

7.  Variables predictive of outcome in 832 patients undergoing repairs of the descending thoracic aorta.

Authors:  L G Svensson; E S Crawford; K R Hess; J S Coselli; H J Safi
Journal:  Chest       Date:  1993-10       Impact factor: 9.410

8.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.

Authors:  C A Nienaber; R Fattori; G Lund; C Dieckmann; W Wolf; Y von Kodolitsch; V Nicolas; A Pierangeli
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

9.  Endovascular stent-grafting for descending thoracic aortic aneurysms.

Authors:  Robin H Heijmen; Ivo G Deblier; Frans L Moll; Karl M Dossche; Jos C van den Berg; Tim Th Overtoom; Sjef M Ernst; Marc A Schepens
Journal:  Eur J Cardiothorac Surg       Date:  2002-01       Impact factor: 4.191

10.  Surgical treatment of thoracoabdominal aortic aneurysms by simple crossclamping. Risk factors and late results.

Authors:  M A Schepens; J J Defauw; R P Hamerlijnck; R De Geest; F E Vermeulen
Journal:  J Thorac Cardiovasc Surg       Date:  1994-01       Impact factor: 5.209

View more
  3 in total

Review 1.  Interventional MDCT.

Authors:  Thomas J Vogl; Joern O Balzer; Martin G Mack; Christopher Herzog
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Placement of endovascular stent-grafts for emergency repair of acute traumatic aortic rupture: a single-centre experience.

Authors:  I E Steingruber; B V Czermak; A Chemelli; B Glodny; J Bonatti; W Jaschke; P Waldenberger; M Rieger; B Neuhauser
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

3.  The Time-Domain Integration Method of Digital Subtraction Angiography Images.

Authors:  Shuo Huang; Le Cheng; Bin Zhu; Ping Zhou; Yu Sun; Bing Zhang; Suiren Wan
Journal:  Comput Math Methods Med       Date:  2018-09-30       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.