Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm.

L Xing1, Y Chen, G Luxton, J G Li, A L Boyer.   

Abstract

An important issue in intensity modulated radiation therapy (IMRT) is the verification of the monitor unit (MU) calculation of the planning system using an independent procedure. Because of the intensity modulation and the dynamic nature of the delivery process, the problem becomes much more involved than that in conventional radiation therapy. In this work, a closed formula for MU calculation is derived. The approach is independent of the specific form of leaf sequence algorithms. It is straightforward to implement the procedure using a simple computer program. The approach is illustrated by a simplified example and is demonstrated by a few CORVUS (NOMOS Corporation, Sewickley, PA) treatment plans. The results indicate that it is robust and suitable for IMRT MU verification.

Mesh:

Year:  2000        PMID: 10730973     DOI: 10.1088/0031-9155/45/3/401

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Independent calculation of monitor units for VMAT and SPORT.

Authors:  Xin Chen; Karl Bush; Aiping Ding; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

2.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different detector-phantom combinations: A comparative study.

Authors:  Biplab Sarkar; Bhaswar Ghosh; Sukumaran Mahendramohan; Ayan Basu; Jyotirup Goswami; Amitabh Ray
Journal:  J Med Phys       Date:  2010-07

4.  Intensity modulated radiotherapy: advantages, limitations and future developments.

Authors:  Ky Cheung
Journal:  Biomed Imaging Interv J       Date:  2006-01-01

5.  Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.

Authors:  M A MacKenzie; M Lachaine; B Murray; B G Fallone; D Robinson; G C Field
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Independent calculation of dose from a helical TomoTherapy unit.

Authors:  John P Gibbons; Koren Smith; Dennis Cheek; Isaac Rosen
Journal:  J Appl Clin Med Phys       Date:  2009-02-05       Impact factor: 2.102

7.  Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program.

Authors:  J J Haslam; D V Bonta; A E Lujan; C Rash; W Jackson; J C Roeske
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

8.  Commissioning results of an automated treatment planning verification system.

Authors:  Christopher L Nelson; Bryan E Mason; Ronald C Robinson; Kelly D Kisling; Steven M Kirsner
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102