Literature DB >> 10709521

Wear behavior of precision attachments.

M G Wichmann1, W Kuntze.   

Abstract

PURPOSE: The purpose of this article was to compare the wear behavior of precision attachments with plastic inserts to conventional metal-alloy precision attachments.
MATERIALS AND METHODS: In a comparative study attachments of various designs were subjected to alternating load cycles in a wear simulator. In addition to conventional adjustable attachments with metal-alloy matrix and patrix elements, attachments with female elements that are lined with plastic inserts were investigated for the first time. In each wear test 10,000 separating and joining movements were performed in an axial direction under a continuous spray of artificial saliva at 37 degrees C.
RESULTS: The attachments with metal surfaces showed a rapid loss of approximately 60% of the required separating/joining forces during the first 1,000 cycles; after a further 9,000 cycles these forces fell to 25% and 35%, respectively, of the initial value. The attachments with plastic inserts, by contrast, showed only a 4% and 8% loss, respectively, of the required separating/joining forces even after 10,000 wear cycles. With one attachment type a reproducible 20% increase of retention occurred during the testings.
CONCLUSION: The precision attachments with plastic female inserts showed only negligible amounts of wear and the most consistent retentive force in comparison with conventional precision attachments consisting of metal-alloy matrix and patrix components.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10709521

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  8 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Retention and surface changes of zirconia primary crowns with secondary crowns of different materials.

Authors:  Işıl Turp; Ergün Bozdağ; Emin Sünbüloğlu; Cem Kahruman; Ibrahim Yusufoğlu; Gülsen Bayraktar
Journal:  Clin Oral Investig       Date:  2014-01-31       Impact factor: 3.573

3.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  Achieving an esthetic smile with fixed and removal prosthesis using extracoronal castable precision attachments.

Authors:  Sharad Vaidya; Charu Kapoor; Yujika Bakshi; Sonam Bhalla
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

6.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

7.  Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.

Authors:  Antonio Gabriel Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-12-27

8.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  8 in total