Literature DB >> 10696028

The effect of contrast material on transcranial Doppler evaluation of normal middle cerebral artery peak systolic velocity.

H G Khan1, P Gailloud, R O Bude, J B Martin, K T Szopinski, C Khaw, D A Rüfenacht, K J Murphy.   

Abstract

BACKGROUND AND
PURPOSE: Several recent studies have shown that sonographic contrast agents may affect transcranial Doppler evaluation of the arterial peak systolic velocity (PSV). Some investigators reported an increase in PSV, and others reported no change in PSV compared with baseline values. This study was conducted to determine the effect of sonographic contrast agent on PSV measured in normal middle cerebral arteries.
METHODS: Continuous spectral Doppler sonography was performed on the right middle cerebral artery of 20 participants with angiographically proven normal intracranial vasculature. Videotaping was performed in each case from the initiation of the administration of contrast medium until the effect of the contrast agent on the PSV subsided. The PSV values were normalized for each participant, were pooled, and were plotted as a function of time.
RESULTS: PSV increased in all participants after the administration of contrast material; the mean maximum increase was 24+/-7.4% (mean +/- standard deviation) (range, 15-36%). The mean duration of PSV increase was 320+/-97 s (range, 165-465 s).
CONCLUSION: The middle cerebral artery PSV increased substantially after the administration of contrast material. This effect needs to be considered if velocity thresholds developed for disease detection without the use of contrast materials are used when contrast agents are administered.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10696028      PMCID: PMC7975360     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  17 in total

1.  Transcranial Doppler ultrasonography for the evaluation of shunt malfunction in pediatric patients.

Authors:  W M Chadduck; H M Crabtree; J B Blankenship; J Adametz
Journal:  Childs Nerv Syst       Date:  1991-02       Impact factor: 1.475

Review 2.  Contrast agents in diagnostic ultrasound.

Authors:  J Ophir; K J Parker
Journal:  Ultrasound Med Biol       Date:  1989       Impact factor: 2.998

3.  Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion: preliminary experience.

Authors:  T Albrecht; A Urbank; M Mahler; A Bauer; C J Doré; M J Blomley; D O Cosgrove; R Schlief
Journal:  Radiology       Date:  1998-05       Impact factor: 11.105

4.  [Contrast agent enhanced duplex ultrasonography: visualization of the hepatic artery after orthotopic liver transplantation].

Authors:  M Gutberlet; S Venz; R Neuhaus; T Ehrenstein; A J Lemke; T J Vogl; N Hosten; P Neuhaus; R Felix
Journal:  Rofo       Date:  1997-05

5.  An investigation of the relationship between ultrasound echo enhancement and Doppler frequency shift using a pulsatile arterial flow phantom.

Authors:  J Petrick; M Zomack; R Schlief
Journal:  Invest Radiol       Date:  1997-04       Impact factor: 6.016

6.  Diagnostic impact and prognostic relevance of early contrast-enhanced transcranial color-coded duplex sonography in acute stroke.

Authors:  M Goertler; R Kross; M Baeumer; S Jost; R Grote; S Weber; C W Wallesch
Journal:  Stroke       Date:  1998-05       Impact factor: 7.914

7.  Artifacts in ultrasonic contrast agent studies.

Authors:  F Forsberg; J B Liu; P N Burns; D A Merton; B B Goldberg
Journal:  J Ultrasound Med       Date:  1994-05       Impact factor: 2.153

8.  Use of intravenous contrast material in transcranial sonography.

Authors:  K J Murphy; R O Bude; L D Dickinson; J M Rubin
Journal:  Acad Radiol       Date:  1997-08       Impact factor: 3.173

9.  Do ultrasonic contrast agents artificially increase maximum Doppler shift? In vivo study of human common carotid arteries.

Authors:  M Gutberlet; S Venz; W Zendel; N Hosten; R Felix
Journal:  J Ultrasound Med       Date:  1998-02       Impact factor: 2.153

10.  Postoperative monitoring of cerebral blood flow in patients harboring intracranial aneurysms.

Authors:  L P Carter; T Grahm; J M Zabramski; C A Dickman; L J Lopez; D H Tallman; R F Spetzler
Journal:  Neurol Res       Date:  1990-12       Impact factor: 2.448

View more
  1 in total

1.  Effect of microbubble contrast on intracranial blood flow velocity assessed by transcranial Doppler.

Authors:  Nicola Logallo; Annette Fromm; Ulrike Waje-Andreassen; Lars Thomassen; Knut Matre
Journal:  J Ultrasound       Date:  2014-01-29
  1 in total