Literature DB >> 9577478

Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion: preliminary experience.

T Albrecht1, A Urbank, M Mahler, A Bauer, C J Doré, M J Blomley, D O Cosgrove, R Schlief.   

Abstract

PURPOSE: To investigate whether continuous infusion of an echo-enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement.
MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed.
RESULTS: All infusions provided an equilibrium plateau of constant prolonged enhancement starting after 1-2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion.
CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.

Mesh:

Substances:

Year:  1998        PMID: 9577478     DOI: 10.1148/radiology.207.2.9577478

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  18 in total

Review 1.  Microbubble contrast agents: a new era in ultrasound.

Authors:  M J Blomley; J C Cooke; E C Unger; M J Monaghan; D O Cosgrove
Journal:  BMJ       Date:  2001-05-19

2.  Value of contrast-enhanced power Doppler ultrasonography (US) of the metacarpophalangeal joints on rheumatoid arthritis.

Authors:  Andrea Klauser; Ferdinand Frauscher; Michael Schirmer
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

3.  Contrast enhanced endoscopic ultrasound: More than just a fancy Doppler.

Authors:  Rachid M Mohamed; Brian M Yan
Journal:  World J Gastrointest Endosc       Date:  2010-07-16

4.  Contrast sonovenography - Is this the answer to complex deep vein thrombosis imaging?

Authors:  Agw Smith; P Parker; O Byass; K Chiu
Journal:  Ultrasound       Date:  2016-01-19

Review 5.  [Ultrasound contrast agents: substance classes, pharmacokinetics, clinical applications, safety aspects].

Authors:  C Krestan
Journal:  Radiologe       Date:  2005-06       Impact factor: 0.635

Review 6.  Recent applications of ultrasound: diagnosis and treatment of hepatocellular carcinoma.

Authors:  Hitoshi Maruyama; Masaaki Ebara
Journal:  Int J Clin Oncol       Date:  2006-08       Impact factor: 3.402

7.  Effect of microbubble contrast on intracranial blood flow velocity assessed by transcranial Doppler.

Authors:  Nicola Logallo; Annette Fromm; Ulrike Waje-Andreassen; Lars Thomassen; Knut Matre
Journal:  J Ultrasound       Date:  2014-01-29

8.  Vascular perfusion kinetics by contrast-enhanced ultrasound are related to synovial microvascularity in the joints of psoriatic arthritis.

Authors:  Ugo Fiocco; Roberto Stramare; Alessandro Coran; Enrico Grisan; Elena Scagliori; Francesco Caso; Luisa Costa; Francesca Lunardi; Francesca Oliviero; Fulvia Chieco Bianchi; Anna Scanu; Veronica Martini; Daniele Boso; Valeria Beltrame; Maristella Vezzù; Luisella Cozzi; Raffaele Scarpa; David Sacerdoti; Leonardo Punzi; Andrea Doria; Fiorella Calabrese; Leopoldo Rubaltelli
Journal:  Clin Rheumatol       Date:  2015-02-14       Impact factor: 2.980

9.  The effect of contrast material on transcranial Doppler evaluation of normal middle cerebral artery peak systolic velocity.

Authors:  H G Khan; P Gailloud; R O Bude; J B Martin; K T Szopinski; C Khaw; D A Rüfenacht; K J Murphy
Journal:  AJNR Am J Neuroradiol       Date:  2000-02       Impact factor: 3.825

10.  Microbubble ultrasound contrast in the assessment of hepatic artery patency following liver transplantation: role in reducing frequency of hepatic artery arteriography.

Authors:  Paul S Sidhu; Ashley S Shaw; Stephen M Ellis; John B Karani; Suzanne M Ryan
Journal:  Eur Radiol       Date:  2003-10-03       Impact factor: 5.315