Literature DB >> 10693572

Does axial limb rotation affect the alignment measurements in deformed limbs?

K E Swanson1, G W Stocks, P D Warren, M R Hazel, H F Janssen.   

Abstract

The long-term outcome of total knee arthroplasty and femoral or tibial osteotomy is related to the ability of the surgeon to achieve the desired alignment based on preoperative planning. This study evaluates the effect of axial rotation on measured tibiofemoral angles and the angle formed between the anatomic and mechanical axes of the femur in lower extremities with valgus and varus deformities. A comparison study of the measured tibiofemoral angles indicated a statistically significant effect in models with severe vagus or varus deformity when rotated 10 degrees internally or externally. In the second part of the study, the measured angle between the anatomic and mechanical axes of the femur never varied by more than 1 degree, despite a 40 degrees are of rotation. The results of the study indicate the tibiofemoral angle measurements are more sensitive to axial limb rotation in lower extremities with valgus or varus deformity than are normally aligned limbs. In preoperative planning of total knee arthroplasty, the measured angle between the anatomic and mechanical axes of the femur is less effected by limb rotation, regardless of the degree of valgus or varus deformity.

Entities:  

Mesh:

Year:  2000        PMID: 10693572     DOI: 10.1097/00003086-200002000-00029

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  36 in total

1.  [CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study].

Authors:  H Bäthis; L Perlick; C Lüring; T Kalteis; J Grifka
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  Length and angle measurements of the lower extremity in digital composite overview images.

Authors:  M Boewer; H Arndt; P A W Ostermann; J Petersein; S Mutze
Journal:  Eur Radiol       Date:  2004-05-26       Impact factor: 5.315

3.  Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; C Perlick; J Grifka
Journal:  Int Orthop       Date:  2004-01-17       Impact factor: 3.075

4.  Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Hoser; Sebastian Quirbach; Rene Attal; Alfred Hennerbichler; Christian Fink
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

5.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

6.  Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy.

Authors:  JianHui Shi; Wei Lv; Yan Wang; Ben Ma; Wei Cui; ZhenZhong Liu; KeCheng Han
Journal:  Int Orthop       Date:  2018-06-27       Impact factor: 3.075

7.  The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Fink; Sebastian Quirbach; Rene Attal; Katja Tecklenburg; Christian Hoser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-20       Impact factor: 4.342

8.  Individual valgus correction angle improves accuracy of postoperative limb alignment restoration after total knee arthroplasty.

Authors:  Xiaojun Shi; Hai Li; Zongke Zhou; Bin Shen; Jing Yang; Pengde Kang; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-01       Impact factor: 4.342

9.  Functional and perceived response to intra-articular hyaluronan injection in patients with knee osteoarthritis: persistence of treatment effects over 5 months.

Authors:  Kristin Briem; Michael J Axe; Lynn Snyder-Mackler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-19       Impact factor: 4.342

10.  Knee rotation influences the femoral tunnel angle measurement after anterior cruciate ligament reconstruction: a 3-dimensional computed tomography model study.

Authors:  Jing Tang; Eric Thorhauer; Chelsea Marsh; Freddie H Fu; Scott Tashman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-16       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.