Literature DB >> 21081582

64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model.

N-S Holalkere1, K Matthes, S P Kalva, W R Brugge, D V Sahani.   

Abstract

OBJECTIVE: In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml(-1)) and high-concentration contrast media (HCCM) (370 mg I ml(-1)) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose.
METHODS: CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml(-1)), Group B (HCCM; 370 mg I ml(-1)) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg(-1)) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test.
RESULTS: The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose.
CONCLUSION: 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21081582      PMCID: PMC3473870          DOI: 10.1259/bjr/14535110

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model.

Authors:  K T Bae; H Q Tran; J P Heiken
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

Review 2.  Liver imaging with MDCT and high concentration contrast media.

Authors:  Audrey L Spielmann
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

Review 3.  Use of high concentration contrast media (HCCM): principles and rationale--body CT.

Authors:  James A Brink
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

4.  A comparison between two different concentration of contrast media with multidetector CT for the study of abdominal vascular system.

Authors:  Ettore Squillaci; Ezio Fanucci; Salvatore Masala; Alberto Nisini; Marco Tomassini; Giovanni Simonetti
Journal:  Radiol Med       Date:  2002-10       Impact factor: 3.469

Review 5.  Present and future trends in multiple detector-row CT applications: CT angiography.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2002-07       Impact factor: 5.315

Review 6.  High-resolution CT angiography of the abdomen.

Authors:  C Catalano; A Laghi; F Fraioli; F Pediconi; A Napoli; M Danti; R Passariello
Journal:  Abdom Imaging       Date:  2002 Sep-Oct

Review 7.  Multiphasic contrast-enhanced multidetector-row CT of liver: contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material.

Authors:  Tomoaki Ichikawa; Sukru Mehmet Erturk; Tsutomu Araki
Journal:  Eur J Radiol       Date:  2006-01-18       Impact factor: 3.528

8.  64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

Authors:  David Maintz; Harald Seifarth; Rainer Raupach; Thomas Flohr; Michael Rink; Torsten Sommer; Murat Ozgün; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-12-07       Impact factor: 5.315

9.  Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model.

Authors:  J K Han; A Y Kim; K Y Lee; J B Seo; T K Kim; B I Choi; C S Lhee; M C Han
Journal:  J Comput Assist Tomogr       Date:  2000 May-Jun       Impact factor: 1.826

10.  Contrast media in abdominal computed tomography: optimization of delivery methods.

Authors:  J K Han; B I Choi; A Y Kim; S J Kim
Journal:  Korean J Radiol       Date:  2001 Jan-Mar       Impact factor: 3.500

View more
  2 in total

1.  Computed tomography portography of patients with cirrhosis with normal body mass index: Comparison between low-tube-voltage CT with low contrast agent dose and conventional CT.

Authors:  Sulan Liu; Huaqiang Sheng; Hao Shi; Wei Li; Jingli Fan; Jingzhen He; Hongjun Sun
Journal:  Medicine (Baltimore)       Date:  2018-11       Impact factor: 1.817

2.  Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT.

Authors:  Makoto Sakane; Tonsok Kim; Masatoshi Hori; Hiromitsu Onishi; Atsushi Nakamoto; Takahiro Tsuboyama; Mitsuaki Tatsumi; Noriyuki Tomiyama
Journal:  Springerplus       Date:  2014-05-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.