The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three dimensional treatment planning system (Helax-TMS, Helax AB, Sweden) to allow conformal planning techniques using irregularly shaped fields, proton range modulation, range modification and dose calculation for non-coplanar beams. The pencil kernel algorithm is developed from the Fermi Eyges formalism and Molière multiple-scattering theory with range straggling corrections applied. The depth penetration algorithm is based on the energy loss in the continuous slowing down approximation with simple correction factors applied to the beam penumbra region and has been implemented for fast, interactive treatment planning. Modelling of the effects of air gaps and range modifying device thickness and position are implicit to both algorithms. Measured and calculated dose values are compared for a therapeutic proton beam in both homogeneous and heterogeneous phantoms of varying complexity. Both algorithms model the beam penumbra as a function of depth in a homogeneous phantom with acceptable accuracy. Results show that the pencil kernel algorithm is required for modelling the dose perturbation effects from scattering in heterogeneous media.

Mesh:

Substances:

Year:  2000        PMID: 10661580     DOI: 10.1088/0031-9155/45/1/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.

Authors:  David C Westerly; Xiaohu Mo; Wolfgang A Tomé; Thomas R Mackie; Paul M DeLuca
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Benchmark measurements and simulations of dose perturbations due to metallic spheres in proton beams.

Authors:  Wayne D Newhauser; Laura Rechner; Dragan Mirkovic; Pablo Yepes; Nicholas C Koch; Uwe Titt; Jonas D Fontenot; Rui Zhang
Journal:  Radiat Meas       Date:  2013-11-01       Impact factor: 1.898

3.  Monte Carlo study of radial energy deposition from primary and secondary particles for narrow and large proton beamlet source models.

Authors:  Christopher R Peeler; Uwe Titt
Journal:  Phys Med Biol       Date:  2012-05-23       Impact factor: 3.609

4.  Beyond Gaussians: a study of single-spot modeling for scanning proton dose calculation.

Authors:  Yupeng Li; Ronald X Zhu; Narayan Sahoo; Aman Anand; Xiaodong Zhang
Journal:  Phys Med Biol       Date:  2012-02-01       Impact factor: 3.609

5.  Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

6.  A revision of proton machine quality assurance for wobbled-proton-beam therapy.

Authors:  Yuki Kase; Haruo Yamashita; Masumi Numano; Hiroshi Fuji; Shigeyuki Murayama
Journal:  Radiol Phys Technol       Date:  2013-05-21

7.  Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy.

Authors:  Pablo Yepes; Antony Adair; David Grosshans; Dragan Mirkovic; Falk Poenisch; Uwe Titt; Qianxia Wang; Radhe Mohan
Journal:  Phys Med Biol       Date:  2018-02-09       Impact factor: 3.609

8.  Long-term evaluation of the effect of hypofractionated high-energy proton treatment of benign meningiomas by means of (11)C-L-methionine positron emission tomography.

Authors:  Mats Ryttlefors; Torsten Danfors; Francesco Latini; Anders Montelius; Erik Blomquist; Olafur Gudjonsson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-01-28       Impact factor: 9.236

9.  Fast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model.

Authors:  Joakim da Silva; Richard Ansorge; Rajesh Jena
Journal:  Front Oncol       Date:  2015-12-18       Impact factor: 6.244

10.  Dose mapping sensitivity to deformable registration uncertainties in fractionated radiotherapy - applied to prostate proton treatments.

Authors:  David Tilly; Nina Tilly; Anders Ahnesjö
Journal:  BMC Med Phys       Date:  2013-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.