Literature DB >> 23689901

A revision of proton machine quality assurance for wobbled-proton-beam therapy.

Yuki Kase1, Haruo Yamashita, Masumi Numano, Hiroshi Fuji, Shigeyuki Murayama.   

Abstract

Periodic checks for proton machine quality assurance (QA) are significant for machine users safely and accurately to provide proton-beam treatment for cancer. Our aim in this study was to describe a revision to proton machine QA procedures for wobbled-proton-beam therapy at the Shizuoka Cancer Center (SCC) in Japan. The previous daily, monthly, and annual QA procedures were determined by reference to our past operational experience and to QA papers for medical accelerators. The revised QA procedures were initiated in May 2011 after preliminary measurements to decide baselines for the QA procedures. This paper presents the proton machine QA procedures and the results of representative QA measurements. Three action levels were decided on by reference to the American Association of Physicists in Medicine Task Group 142 report. Tolerances of inspection action were decided on based on the provisional operational results and actual fluctuations of the QA measurement for a year, and those of scheduled action and stop-treatment action were determined by reference to the machine QA papers and those of the inspection action. No deviation from the tolerance of the scheduled action has been observed so far. Although a few QA procedures exceeded the tolerance of the inspection action, these excesses were resolved by inspection and improvement of the respective measuring procedure within the designated QA time. Hereafter, the proton machine QA procedures proposed in this study will be performed continuously at the SCC to assure patient safety and accurate operation of proton therapy.

Entities:  

Mesh:

Year:  2013        PMID: 23689901     DOI: 10.1007/s12194-013-0217-2

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  9 in total

1.  Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams.

Authors:  K R Russell; U Isacsson; M Saxner; A Ahnesjö; A Montelius; E Grusell; C V Dahlgren; S Lorin; B Glimelius
Journal:  Phys Med Biol       Date:  2000-01       Impact factor: 3.609

2.  A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning.

Authors:  Nobuyuki Kanematsu; Naruhiro Matsufuji; Ryosuke Kohno; Shinichi Minohara; Tatsuaki Kanai
Journal:  Phys Med Biol       Date:  2003-04-21       Impact factor: 3.609

3.  Ridge filter design for proton therapy at Hyogo Ion Beam Medical Center.

Authors:  Takashi Akagi; Akio Higashi; Hironobu Tsugami; Hidenobu Sakamoto; Yasutaka Masuda; Yoshio Hishikawa
Journal:  Phys Med Biol       Date:  2003-11-21       Impact factor: 3.609

4.  Radiological use of fast protons.

Authors:  R R WILSON
Journal:  Radiology       Date:  1946-11       Impact factor: 11.105

5.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

Review 6.  An overview of the comprehensive proton therapy machine quality assurance procedures implemented at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center-Houston.

Authors:  Bijan Arjomandy; Narayan Sahoo; X Ronald Zhu; John R Zullo; Richard Y Wu; Mingping Zhu; Xiaoning Ding; Craig Martin; George Ciangaru; Michael T Gillin
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.

Authors:  G J Kutcher; L Coia; M Gillin; W F Hanson; S Leibel; R J Morton; J R Palta; J A Purdy; L E Reinstein; G K Svensson
Journal:  Med Phys       Date:  1994-04       Impact factor: 4.071

8.  [Initial clinical experience of proton therapy at Shizuoka Cancer Center].

Authors:  Shigeyuki Murayama; Hiroshi Fuji; Haruo Yamashita; Yasuyuki Futami; Masumi Numano; Hideyuki Harada; Minoru Kamata; Tetsuo Nishimura
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  2005-10

9.  Respiratory gated irradiation system for heavy-ion radiotherapy.

Authors:  S Minohara; T Kanai; M Endo; K Noda; M Kanazawa
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

  9 in total
  1 in total

1.  Daily QA in proton therapy using a single commercially available detector.

Authors:  Jamil Lambert; Christian Bäumer; Benjamin Koska; Xiaoning Ding
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.