Literature DB >> 24445789

[Risk of perioperative mortality and complications following biological aortic valve replacement in elderly patients: stented vs unstented bioprotheses].

J Ennker1, I Florath, U Rosendahl, S Bauer, E von Hodenberg, I C Ennker.   

Abstract

Recently published studies suggest that the hemodynamic advantage of stentless bioprostheses in comparison to stented bioprostheses positively influence the long-term survival after aortic valve replacement. However, the more complex and time consuming implantation technique may increase the risk of operative death. Between April 1996 and September 2000, 201 patients with the mean age of 75 ± 5 years underwent aortic valve replacement (AVR) with a stentless Medtronic Freestyle Bioprothesis (FP) and 166 patients with a mean age of 77 ± 5 years received a stented Medtronic Mosaic Biopros thesis (MP). Patients requiring concomitant procedures other than coronary artery bypass grafting (CABG) were excluded. The operative mortality was 3.5% after AVR with the FP and 6% after AVR with the MP. Multiple logistic regression analysis considering the different patient populations revealed no increased risk of operative death after AVR with FB (p = 0.46). Previously heart operations (p = 0.046) and emergency operation (p = 0.022) were risk factors for operative death after AVR with the biological bioprostheses. The risk for postoperatively neurological impairment (p = 0.15) and other complications (p = 0.46) was furthermore not increased after implantation of a Freestyle stentless valve. The risk of delayed mobilization (p < 0.001) was 2.4-fold increased for patients after AVR with the Freestyle valve. A positive influence on survival due to the implantation of a stentless Freestyle valve could not be shown within the observed period. However, in spite of the more complex and time-consuming operation technique, the risk of operative death and postoperative complications is not increased after aortic valve replacement with the stentless FB.

Entities:  

Year:  2001        PMID: 24445789     DOI: 10.1007/s003920170009

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  24 in total

1.  Prospectively randomized evaluation of stentless versus conventional biological aortic valves: impact on early regression of left ventricular hypertrophy.

Authors:  T Walther; V Falk; G Langebartels; M Krüger; U Bernhardt; A Diegeler; J Gummert; R Autschbach; F W Mohr
Journal:  Circulation       Date:  1999-11-09       Impact factor: 29.690

2.  Changes in left ventricular mass and function after aortic valve replacement: a comparison between stentless and stented bioprosthetic valves.

Authors:  P Pibarot; J G Dumesnil; M H Leblanc; P Cartier; J Métras
Journal:  J Am Soc Echocardiogr       Date:  1999-11       Impact factor: 5.251

3.  Ten-year experience with aortic valve replacement in 482 patients 70 years of age or older: operative risk and long-term results.

Authors:  A C Galloway; S B Colvin; E A Grossi; F G Baumann; Y P Sabban; R Esposito; G H Ribakove; A T Culliford; J N Slater; E Glassman
Journal:  Ann Thorac Surg       Date:  1990-01       Impact factor: 4.330

4.  Prosthesis-patient mismatch: hemodynamic comparison of stented and stentless aortic valves.

Authors:  K L Yun; W R Jamieson; S Khonsari; L H Burr; A I Munro; C F Sintek
Journal:  Semin Thorac Cardiovasc Surg       Date:  1999-10

5.  Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves.

Authors:  D F Del Rizzo; A Abdoh; P Cartier; D Doty; S Westaby
Journal:  Semin Thorac Cardiovasc Surg       Date:  1999-10

6.  Prognostic implications of echocardiographically determined left ventricular mass in the Framingham Heart Study.

Authors:  D Levy; R J Garrison; D D Savage; W B Kannel; W P Castelli
Journal:  N Engl J Med       Date:  1990-05-31       Impact factor: 91.245

7.  Stentless or stented aortic valve implants in elderly patients?

Authors:  G Van Nooten; F Caes; K François; Y Van Belleghem; Y Taeymans
Journal:  Eur J Cardiothorac Surg       Date:  1999-01       Impact factor: 4.191

8.  Left ventricular remodelling and improvement in Freestyle stentless valve haemodynamics.

Authors:  X Y Jin; S Westaby; D G Gibson; R Pillai; D P Taggart
Journal:  Eur J Cardiothorac Surg       Date:  1997-07       Impact factor: 4.191

9.  Retrospective clinical analysis of stented vs. stentless porcine aortic bioprostheses.

Authors:  M Vrandecic; F A Fantini; B G Filho; O C de Oliveira; I M da Costa Júnior; E Vrandecic
Journal:  Eur J Cardiothorac Surg       Date:  2000-07       Impact factor: 4.191

10.  Aortic valve replacement: determinants of operative mortality.

Authors:  G W He; T E Acuff; W H Ryan; M B Douthit; R T Bowman; Y H He; M J Mack
Journal:  Ann Thorac Surg       Date:  1994-05       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.