Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT.

C H Coulam1, D H Sheafor, R A Leder, E K Paulson, D M DeLong, R C Nelson.   

Abstract

OBJECTIVE: The purpose of our study was to evaluate renal cyst pseudoenhancement during helical CT in a phantom model and in patients.
MATERIALS AND METHODS: Iodine baths containing water-filled spheres and cylinders were constructed to simulate cysts in enhancing renal parenchyma. Iodine concentration, cyst size and location, collimation, and peak kilovoltage were varied and cyst attenuation was measured. Data were analyzed with the mixed linear models and Mantel-Haenszel tests. Subsequently, a paired t test compared CT attenuation values before and after contrast material enhancement in 40 patients with 68 renal cysts (radiographic stability >3 months).
RESULTS: The attenuation values of phantom cysts increased when placed in a contrast media bath (p = 0.001). The increase in attenuation values became more pronounced with increasing iodine concentrations, decreasing peak kilovoltage, and smaller sphere sizes. In patients, mean cyst attenuation increased 3.4 +/- 6.2 H after administration of contrast material (p = 0.00002). The attenuation did not increase more than 10 H in any of the 37 cysts larger than 2 cm found in patients. Eight (26%) of the 31 cysts smaller than 2 cm found in patients increased by at least 10 H.
CONCLUSION: In a phantom model, at simulated physiologic levels of renal enhancement, cysts may pseudoenhance by more than 10 H. Similarly, in patients, cysts may also pseudoenhance; however, most pseudoenhancement does not exceed 10 H. In patients, pseudoenhancement of at least 10 H is more likely in cysts smaller than 2 cm.

Entities:  

Mesh:

Year:  2000        PMID: 10658730     DOI: 10.2214/ajr.174.2.1740493

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Authors:  Izuru Matsuda; Masaaki Akahane; Jiro Sato; Masaki Katsura; Shigeru Kiryu; Naoki Yoshioka; Akira Kunimatsu; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

2.  Renal cyst pseudoenhancement at multidetector CT: what are the effects of number of detectors and peak tube voltage?

Authors:  Zhen J Wang; Fergus V Coakley; Yanjun Fu; Bonnie N Joe; Sven Prevrhal; Luis A Landeras; Emma M Webb; Benjamin M Yeh
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

3.  Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study.

Authors:  C L Brown; R P Hartman; O P Dzyubak; N Takahashi; A Kawashima; C H McCollough; M R Bruesewitz; A M Primak; J G Fletcher
Journal:  Eur Radiol       Date:  2009-01-20       Impact factor: 5.315

4.  In vivo predictors of renal cyst pseudoenhancement at 120 kVp.

Authors:  Jeet Patel; Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; James H Ellis; Joel F Platt
Journal:  AJR Am J Roentgenol       Date:  2014-02       Impact factor: 3.959

Review 5.  Magnetic Resonance Imaging and the Use in Small Renal Masses.

Authors:  M Vedanayagam; B Bhattacharya; S Sriprasad
Journal:  Indian J Surg Oncol       Date:  2016-12-05

6.  An EM approach to MAP solution of segmenting tissue mixture percentages with application to CT-based virtual colonoscopy.

Authors:  Su Wang; Lihong Li; Harris Cohen; Seth Mankes; John J Chen; Zhengrong Liang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  The characterization of small hypoattenuating renal masses on contrast-enhanced CT.

Authors:  Neesha S Patel; Liina Poder; Zhen J Wang; Benjamin M Yeh; Aliya Qayyum; Hua Jin; Fergus V Coakley
Journal:  Clin Imaging       Date:  2009 Jul-Aug       Impact factor: 1.605

8.  Assessment and characterisation of common renal masses with CT and MRI.

Authors:  Leo Pallwein-Prettner; Daniel Flöry; Claus Raphael Rotter; Kurt Pogner; Gerhard Syré; Claudia Fellner; Ferdinand Frauscher; Friedrich Aigner; Frens Steffen Krause; Franz Fellner
Journal:  Insights Imaging       Date:  2011-07-17

9.  Effect of thin overlapping reconstruction on the attenuation of small (< or = 3 cm) renal cysts in the nephrographic phase of MDCT: a phantom study.

Authors:  Sun Ho Kim; Seung Hyup Kim
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

10.  Renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kVp images obtained during the same CT examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction.

Authors:  Yoshitake Yamada; Minoru Yamada; Koichi Sugisawa; Hirotaka Akita; Eisuke Shiomi; Takayuki Abe; Shigeo Okuda; Masahiro Jinzaki
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.