The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularity.

Z Liu1, S C Pflugfelder.   

Abstract

PURPOSE: To evaluate the effect of long-term contact lens wear on corneal thickness, curvature, and surface regularity.
DESIGN: A prospective, clinic-based, case-control study. PARTICIPANTS: A total of 40 eyes of 20 normal subjects and 64 eyes of 35 subjects wearing contact lenses for more than 5 years were evaluated.
METHODS: The Orbscan Corneal Topography System was used to evaluate the entire corneal thickness and curvature, anterior curvature and the anterior and posterior elevation topographic patterns in normal eyes and subjects wearing contact lenses on a regular basis for more than 5 years. Indices of TMS-1 Corneal Topography System were used to determine corneal surface regularity in subjects wearing contact lenses and normal eyes. All topographic examinations were performed after contact lenses had been removed for at least 2 weeks. MAIN OUTCOME MEASURES: The entire corneal thickness, curvature, surface regularity index (SRI), surface asymmetry index (SAI), potential visual acuity (PVA) and topographic patterns were compared between normal eyes and subjects wearing contact lenses for more than 5 years.
RESULTS: The 64 eyes of 35 subjects evaluated by the Orbscan instrument had an average of 13.45 +/- 6.42 years of contact lens wear. The mean corneal thickness in the center and in eight peripheral areas measured in contact lens wearing subjects was significantly reduced by about 30 to 50 microm compared to normal subjects (P < 0.001 for central and peripheral sites). No correlation was noted between central corneal thickness and degree of myopia in diopters (r = 0.15, 0.10 < P < 0.25). The corneal curvature, maximum keratometry (Max K) and minimum keratometry (Min K) readings, were significantly steeper in eyes wearing contact lenses than normal eyes (P < 0.01 for Max K and Min K measured by both instruments). No difference in the mean corneal astigmatism was noted between groups. The SRI and SAI, but not the PVA index, of the TMS-1 were significantly greater in contact lens wearers than in the control group (P < 0.01 for both SRI and SAI, P = 0.15 for PVA). The color-coded patterns of all curvature and elevation maps made with both instruments showed no significant difference between subjects wearing contact lenses and the control group. There was no significant difference between corneal curvature measurements taken with the Orbscan System or the TMS-1 System in both normal and contact lens groups.
CONCLUSIONS: Long-term contact lens wear appears to decrease the entire corneal thickness and increase the corneal curvature and surface irregularity.

Entities:  

Mesh:

Year:  2000        PMID: 10647727     DOI: 10.1016/s0161-6420(99)00027-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  30 in total

1.  [Acute alteration of corneal topography].

Authors:  K Spaniol; M Roth; T Stupp
Journal:  Ophthalmologe       Date:  2014       Impact factor: 1.059

2.  The relationship between central corneal thickness and degree of myopia among Saudi adults.

Authors:  Hani S Al-Mezaine; Saleh Al-Obeidan; Dustan Kangave; Abdulkareem Sadaawy; Taher A Wehaib; Saleh A Al-Amro
Journal:  Int Ophthalmol       Date:  2008-06-28       Impact factor: 2.031

3.  Comparison of central corneal thickness measurements obtained by community optometrists to those obtained in secondary care.

Authors:  Laura Hughes; Cheng Yi Loo; Brian Hogan; Huai Ling Tan; Ling Shan Tang; Andrew J Tatham
Journal:  Eye (Lond)       Date:  2018-07-23       Impact factor: 3.775

4.  Central corneal thickness and its relationship to myopia in Chinese adults.

Authors:  H-B Fam; A C S How; M Baskaran; K-L Lim; Y-H Chan; T Aung
Journal:  Br J Ophthalmol       Date:  2006-08-17       Impact factor: 4.638

5.  The effect of the timing of the cessation of contact lens use on the results of biometry.

Authors:  Colin Goudie; Andrew Tatham; Rhys Davies; Alison Sifton; Mark Wright
Journal:  Eye (Lond)       Date:  2018-02-02       Impact factor: 3.775

6.  The cornea in young myopic adults.

Authors:  S W Chang; I L Tsai; F R Hu; L L Lin; Y F Shih
Journal:  Br J Ophthalmol       Date:  2001-08       Impact factor: 4.638

7.  The Disinfecting Potential of Contact Lens Soutions used by Sultan Qaboos University Students.

Authors:  B C Nzeako; Sara H Al-Sumri
Journal:  Sultan Qaboos Univ Med J       Date:  2011-05-15

8.  Correlations between magnitude of refractive error and other optical components in Korean myopes.

Authors:  Sangkyu Lee; Boyun Kim; Tae-Hoon Oh; Hyun Seung Kim
Journal:  Korean J Ophthalmol       Date:  2012-09-24

9.  Comparison of central corneal thickness measurements by Pentacam, noncontact specular microscope, and ultrasound pachymetry in normal and post-LASIK eyes.

Authors:  Saleh Al-Ageel; Abdulrahman M Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-10-24

10.  The impact of hybrid contact lenses on keratoconus progression after accelerated transepithelial corneal cross-linking.

Authors:  Mehmet Gökhan Aslan; Hüseyin Fındık; Murat Okutucu; Emre Aydın; Feyzahan Uzun
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.