Literature DB >> 10641963

Assessing the quality of clinical data in a computer-based record for calculating the pneumonia severity index.

D Aronsky1, P J Haug.   

Abstract

OBJECTIVE: This study examined whether clinical data routinely available in a computerized patient record (CPR) can be used to drive a complex guideline that supports physicians in real time and at the point of care in assessing the risk of mortality for patients with community-acquired pneumonia.
SETTING: Emergency department of a tertiary-care hospital.
DESIGN: Retrospective analysis with medical chart review. PATIENTS: All 241 inpatients during a 17-month period (Jun 1995 to Nov 1996) who presented to the emergency department and had a primary discharge diagnosis of community-acquired pneumonia. METHODS/MAIN OUTCOME MEASURES: The 20 guideline variables were extracted from the CPR (HELP System) and the paper chart. The risk score and the risk class of the Pneumonia Severity Index were computed using data from the CPR alone and from a reference standard of all data available in the paper chart and the CPR at the time of the emergency department encounters. Availability and concordance were quantified to determine data quality. The type and cause of errors were analyzed depending on the source and format of the clinical variables.
RESULTS: Of the 20 guideline variables, 12 variables were required to be present for every computer-charted emergency department patient, seven variables were required for selected patients only, and one variable was not typically available in the HELP System during a patient's encounter. The risk class was identical for 86.7 percent of the patients. The majority of patients with different risk classes were assigned too low a risk class. The risk scores were identical for 72.1 percent of the patients. The average availability was 0.99 for the data elements that were required to be present and 0.79 for the data elements that were not required to be present. The average concordance was 0.98 when all a patient's variables were taken into account. The cause of error was attributed to the nurse charting in 77 percent of the cases and to the computerized evaluation in 23 percent. The type of error originated from the free-text fields in 64 percent, from coded fields in 21 percent, from vital signs in 14 percent, and from laboratory results in 1 percent.
CONCLUSION: From a clinical perspective, the current level of data quality in the HELP System supports the automation and the prospective evaluation of the Pneumonia Severity Index as a computerized decision support tool.

Entities:  

Mesh:

Year:  2000        PMID: 10641963      PMCID: PMC61455          DOI: 10.1136/jamia.2000.0070055

Source DB:  PubMed          Journal:  J Am Med Inform Assoc        ISSN: 1067-5027            Impact factor:   4.497


  26 in total

1.  Quality assurance and computer-based patient records.

Authors:  G O Barnett; R N Winickoff
Journal:  Am J Public Health       Date:  1990-05       Impact factor: 9.308

2.  Computerizing guidelines to improve care and patient outcomes: the example of heart failure.

Authors:  W M Tierney; J M Overhage; B Y Takesue; L E Harris; M D Murray; D L Vargo; C J McDonald
Journal:  J Am Med Inform Assoc       Date:  1995 Sep-Oct       Impact factor: 4.497

Review 3.  Computerized patient records in primary care. Their role in mediating guideline-driven physician behavior change.

Authors:  R B Elson; D P Connelly
Journal:  Arch Fam Med       Date:  1995-08

4.  Clinical prediction rules. Have they come of age?

Authors:  J H Wasson; H C Sox
Journal:  JAMA       Date:  1996-02-28       Impact factor: 56.272

5.  Toward electronic medical records that improve care.

Authors:  W M Tierney; J M Overhage; C J McDonald
Journal:  Ann Intern Med       Date:  1995-05-01       Impact factor: 25.391

6.  Guidelines you can follow and can trust. An ideal and an example.

Authors:  C J McDonald; J M Overhage
Journal:  JAMA       Date:  1994-03-16       Impact factor: 56.272

Review 7.  Clinical prediction rules. Applications and methodological standards.

Authors:  J H Wasson; H C Sox; R K Neff; L Goldman
Journal:  N Engl J Med       Date:  1985-09-26       Impact factor: 91.245

8.  Comparison of a disease-specific and a generic severity of illness measure for patients with community-acquired pneumonia.

Authors:  M J Fine; B H Hanusa; J R Lave; D E Singer; R A Stone; L A Weissfeld; C M Coley; T J Marrie; W N Kapoor
Journal:  J Gen Intern Med       Date:  1995-07       Impact factor: 5.128

9.  Randomized clinical trial of pressure-controlled inverse ratio ventilation and extracorporeal CO2 removal for adult respiratory distress syndrome.

Authors:  A H Morris; C J Wallace; R L Menlove; T P Clemmer; J F Orme; L K Weaver; N C Dean; F Thomas; T D East; N L Pace; M R Suchyta; E Beck; M Bombino; D F Sittig; S Böhm; B Hoffmann; H Becks; S Butler; J Pearl; B Rasmusson
Journal:  Am J Respir Crit Care Med       Date:  1994-02       Impact factor: 21.405

10.  Development and implementation of a computer-generated reminder system for diabetes preventive care.

Authors:  D S Nilasena; M J Lincoln; C W Turner; H R Warner; V A Foerster; J W Williamson; B M Stults
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1994
View more
  31 in total

1.  Assessing data quality: from concordance, through correctness and completeness, to valid manipulatable representations.

Authors:  P F Brennan; W W Stead
Journal:  J Am Med Inform Assoc       Date:  2000 Jan-Feb       Impact factor: 4.497

2.  Evaluation of a computerized diagnostic decision support system for patients with pneumonia: study design considerations.

Authors:  D Aronsky; K J Chan; P J Haug
Journal:  J Am Med Inform Assoc       Date:  2001 Sep-Oct       Impact factor: 4.497

Review 3.  Defining and improving data quality in medical registries: a literature review, case study, and generic framework.

Authors:  Danielle G T Arts; Nicolette F De Keizer; Gert-Jan Scheffer
Journal:  J Am Med Inform Assoc       Date:  2002 Nov-Dec       Impact factor: 4.497

4.  Adoption and Barriers to Adoption of Electronic Health Records by Nurses in Three Governmental Hospitals in Eastern Province, Saudi Arabia.

Authors:  Azza El Mahalli
Journal:  Perspect Health Inf Manag       Date:  2015-11-01

5.  Analyzing the effect of data quality on the accuracy of clinical decision support systems: a computer simulation approach.

Authors:  Sharique Hasan; Rema Padman
Journal:  AMIA Annu Symp Proc       Date:  2006

6.  Preliminary development of the physician documentation quality instrument.

Authors:  Peter D Stetson; Frances P Morrison; Suzanne Bakken; Stephen B Johnson
Journal:  J Am Med Inform Assoc       Date:  2008-04-24       Impact factor: 4.497

7.  Nurses' views on electronic medical records (EMR) in Turkey: an analysis according to use, quality and user satisfaction.

Authors:  Mehmet Top; Omer Gider
Journal:  J Med Syst       Date:  2011-02-08       Impact factor: 4.460

8.  Quantifying clinical data quality using relative gold standards.

Authors:  Michael G Kahn; Brian B Eliason; Janet Bathurst
Journal:  AMIA Annu Symp Proc       Date:  2010-11-13

9.  Clinical Research Informatics for Big Data and Precision Medicine.

Authors:  C Weng; M G Kahn
Journal:  Yearb Med Inform       Date:  2016-11-10

10.  Performance evaluation of MR-proadrenomedullin and other scoring systems in severe sepsis with pneumonia.

Authors:  Serdar Akpinar; Kazım Rollas; Ali Alagöz; Fatih Seğmen; Tuğrul Sipit
Journal:  J Thorac Dis       Date:  2014-07       Impact factor: 2.895

View more