Literature DB >> 10586463

The in vitro effects of instrumentation on multilevel cervical strut-graft mechanics.

K T Foley1, D J DiAngelo, Y R Rampersaud, K A Vossel, T H Jansen.   

Abstract

STUDY
DESIGN: Biomechanical study using a programmable testing apparatus that replicated physiologic flexion-extension cervical spine motion, and loading mechanics.
OBJECTIVES: To determine the influence of anterior, posterior, or combined plating on multilevel cervical strut-graft mechanics in vitro. SUMMARY OF BACKGROUND DATA: The addition of instrumentation does not prevent construct failure in multilevel (more than two levels) cervical corpectomy.
METHODS: Six fresh human cadaveric cervical spines (C2-T1) were tested in six sequential conditions that included harvested (H), C4-6 corpectomy, strut grafted, strut grafted with an anterior cervical plate (SGAP), strut grafted with posterior plates (SGPP), and strut grafted with combined anterior and posterior plates (SGAPP). A customized force-sensing strut graft (FSSG) was used to measure axial compression-tension, flexion-extension and lateral bending moments, and axial torsion. Parameters of stiffness, segmental vertebral motion, and strut-graft loads were compared, to determine differences among the spine conditions.
RESULTS: Flexion of the strut-grafted spine loaded the FSSG, and extension motion unloaded the FSSG. With the anterior plate, flexion of the SGAP spine significantly unloaded the FSSG; extension loaded the FSSG more than flexion of the unplated spine (P = 0.03). The opposite occurred with the posterior plates (SGPP), where flexion of the spine significantly loaded the FSSG (more than the strut grafted spine) and extension unloaded the FSSG (P < 0.03). The combined construct (SGAPP) counteracted the tension band effect of the individual plates and demonstrated significantly less overall FSSG load change than either plate alone (P = 0.03).
CONCLUSIONS: Multilevel cervical instrumentation effectively increases stiffness after corpectomy. However, anterior or posterior plating alone excessively loads the graft with small degrees of motion, which may promote pistoning and failure of multilevel constructs.

Entities:  

Mesh:

Year:  1999        PMID: 10586463     DOI: 10.1097/00007632-199911150-00014

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  13 in total

1.  Dynamic simulation of the natural and replaced human ankle joint.

Authors:  A Leardini; D Moschella
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

Review 2.  [Vertebral body replacement in spine surgery].

Authors:  F Kandziora; K J Schnake; C K Klostermann; N P Haas
Journal:  Unfallchirurg       Date:  2004-05       Impact factor: 1.000

3.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

Review 4.  Cervical laminectomy and instrumented lateral mass fusion: techniques, pearls and pitfalls.

Authors:  Michael Mayer; Oliver Meier; Alexander Auffarth; Heiko Koller
Journal:  Eur Spine J       Date:  2013-05-29       Impact factor: 3.134

5.  Comparison of ventral corpectomy and plate-screw-instrumented fusion with dorsal laminectomy and rod-screw-instrumented fusion for treatment of at least two vertebral-level spondylotic cervical myelopathy.

Authors:  Rudolf Andreas Kristof; Thomas Kiefer; Marcus Thudium; Florian Ringel; Michael Stoffel; Attlila Kovacs; Christian-Andreas Mueller
Journal:  Eur Spine J       Date:  2009-08-07       Impact factor: 3.134

6.  Outcomes of three anterior decompression and fusion techniques in the treatment of three-level cervical spondylosis.

Authors:  Qunfeng Guo; Xiaoda Bi; Bin Ni; Xuhua Lu; Jinshui Chen; Jian Yang; Yang Yu
Journal:  Eur Spine J       Date:  2011-03-30       Impact factor: 3.134

7.  Anterior cervical discectomy versus corpectomy for multilevel cervical spondylotic myelopathy: a meta-analysis.

Authors:  Shan-Wen Xiao; Hua Jiang; Li-Jing Yang; Zeng-Ming Xiao
Journal:  Eur Spine J       Date:  2014-10-18       Impact factor: 3.134

8.  Comparison between anterior cervical discectomy fusion and cervical corpectomy fusion using titanium cages for reconstruction: analysis of outcome and long-term follow-up.

Authors:  Juan S Uribe; Jaypal Reddy Sangala; Edward A M Duckworth; Fernando L Vale
Journal:  Eur Spine J       Date:  2009-02-12       Impact factor: 3.134

9.  Efficacy of orthotic immobilization of the unstable subaxial cervical spine of the elderly patient: investigation in a cadaver model.

Authors:  Drew A Bednar
Journal:  Can J Surg       Date:  2004-08       Impact factor: 2.089

Review 10.  4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results.

Authors:  Heiko Koller; Axel Hempfing; Luis Ferraris; Oliver Maier; Wolfgang Hitzl; Peter Metz-Stavenhagen
Journal:  Eur Spine J       Date:  2007-06-29       Impact factor: 3.134

View more