Literature DB >> 17605052

4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results.

Heiko Koller1, Axel Hempfing, Luis Ferraris, Oliver Maier, Wolfgang Hitzl, Peter Metz-Stavenhagen.   

Abstract

In the future, there will be an increased number of cervical revision surgeries, including 4- and more-levels. But, there is a paucity of literature concerning the geometrical and clinical outcome in these challenging reconstructions. To contribute to current knowledge, we want to share our experience with 4- and 5-level anterior cervical fusions in 26 cases in sight of a critical review of literature. At index procedure, almost 50% of our patients had previous cervical surgeries performed. Besides failed prior surgeries, indications included degenerative multilevel instability and spondylotic myelopathy with cervical kyphosis. An average of 4.1 levels was instrumented and fused using constrained (26.9%) and non-constrained (73.1%) screw-plate systems. At all, four patients had 3-level corpectomies, and three had additional posterior stabilization and fusion. Mean age of patients at index procedure was 54 years with a mean follow-up intervall of 30.9 months. Preoperative lordosis C2-7 was 6.5 degrees in average, which measured a mean of 15.6 degrees at last follow-up. Postoperative lordosis at fusion block was 14.4 degrees in average, and 13.6 degrees at last follow-up. In 34.6% of patients some kind of postoperative change in construct geometry was observed, but without any catastrophic construct failure. There were two delayed unions, but finally union rate was 100% without any need for the Halo device. Eleven patients (42.3%) showed an excellent outcome, twelve good (46.2%), one fair (3.8%), and two poor (7.7%). The study demonstrated that anterior-only instrumentations following segmental decompressions or use of the hybrid technique with discontinuous corpectomies can avoid the need for posterior supplemental surgery in 4- and 5-level surgeries. However, also the review of literature shows that decreased construct rigidity following more than 2-level corpectomies can demand 360 degrees instrumentation and fusion. Concerning construct rigidity and radiolographic course, constrained plates did better than non-constrained ones. The discussion of our results are accompanied by a detailed review of literature, shedding light on the biomechanical challenges in multilevel cervical procedures and suggests conclusions.

Entities:  

Mesh:

Year:  2007        PMID: 17605052      PMCID: PMC2140121          DOI: 10.1007/s00586-007-0398-7

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  100 in total

1.  Recurrent laryngeal nerve injury with anterior cervical spine surgery risk with laterality of surgical approach.

Authors:  W J Beutler; C A Sweeney; P J Connolly
Journal:  Spine (Phila Pa 1976)       Date:  2001-06-15       Impact factor: 3.468

2.  Dynamic cervical plates: biomechanical evaluation of load sharing and stiffness.

Authors:  D S Brodke; S Gollogly; R Alexander Mohr; B K Nguyen; A T Dailey
Journal:  Spine (Phila Pa 1976)       Date:  2001-06-15       Impact factor: 3.468

3.  Reoperation rates for acute graft extrusion and pseudarthrosis after one-level anterior corpectomy and fusion with and without plate instrumentation: etiology and corrective management.

Authors:  N E Epstein
Journal:  Surg Neurol       Date:  2001-08

4.  Comparison of axial and flexural stresses in lordosis and three buckled configurations of the cervical spine.

Authors:  D E Harrison; D D Harrison; T J Janik; E William Jones; R Cailliet; M Normand
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001-05       Impact factor: 2.063

Review 5.  Cervical spinal stenosis: outcome after anterior corpectomy, allograft reconstruction, and instrumentation.

Authors:  Matthew T Mayr; Brian R Subach; Christopher H Comey; Gerald E Rodts; Regis W Haid
Journal:  J Neurosurg       Date:  2002-01       Impact factor: 5.115

6.  A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine.

Authors:  Y Do Koh; T H Lim; J Won You; J Eck; H S An
Journal:  Spine (Phila Pa 1976)       Date:  2001-01-01       Impact factor: 3.468

7.  Anterior versus posterior plating in cervical corpectomy.

Authors:  H ElSaghir; H Böhm
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

8.  The arthrodesis rate in multilevel anterior cervical fusions using autogenous fibula.

Authors:  D R Gore
Journal:  Spine (Phila Pa 1976)       Date:  2001-06-01       Impact factor: 3.468

9.  Single-stage anterior-posterior decompression and stabilization for complex cervical spine disorders.

Authors:  K D Schultz; M R McLaughlin; R W Haid; C H Comey; G E Rodts; J Alexander
Journal:  J Neurosurg       Date:  2000-10       Impact factor: 5.115

Review 10.  Internal fixation on the lower cervical spine--biomechanics and clinical practice of procedures and implants.

Authors:  C Ulrich; M Arand; J Nothwang
Journal:  Eur Spine J       Date:  2001-04       Impact factor: 3.134

View more
  35 in total

1.  The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping.

Authors:  Heiko Koller; Rene Schmidt; Michael Mayer; Wolfgang Hitzl; Juliane Zenner; Stefan Midderhoff; Stefan Middendorf; Nicolaus Graf; Nicolaus Gräf; H Resch; Hans-Joachim Wilke; Hans-Joachim Willke
Journal:  Eur Spine J       Date:  2010-06-30       Impact factor: 3.134

2.  Noncontiguous anterior decompression and fusion for multilevel cervical spondylotic myelopathy: a prospective randomized control clinical study.

Authors:  Xiao-Feng Lian; Jian-Guang Xu; Bing-Fang Zeng; Wei Zhou; Wei-Qing Kong; Tie-Sheng Hou
Journal:  Eur Spine J       Date:  2010-02-21       Impact factor: 3.134

3.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

Review 4.  Cervical laminectomy and instrumented lateral mass fusion: techniques, pearls and pitfalls.

Authors:  Michael Mayer; Oliver Meier; Alexander Auffarth; Heiko Koller
Journal:  Eur Spine J       Date:  2013-05-29       Impact factor: 3.134

5.  Anterior transpedicular screw technique for failed anterior cervical internal fixation in revision surgery: a case report.

Authors:  Wei-hu Ma; Liang Yu; Xiao-hu Song; Rong-ming Xu; Yong Hu; Liu-jun Zhao; Shao-hua Sun; Wei-yu Jiang; Yong-jie Gu
Journal:  Orthop Surg       Date:  2013-11       Impact factor: 2.071

6.  Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

Authors:  Heiko Koller; Werner Schmoelz; Juliane Zenner; Alexander Auffarth; Herbert Resch; Wolfgang Hitzl; Davud Malekzadeh; Lukas Ernstbrunner; Martina Blocher; Michael Mayer
Journal:  Eur Spine J       Date:  2015-01-23       Impact factor: 3.134

7.  Anterior transpedicular screws in conjunction with plate fixation and fusion for the treatment of subaxial cervical spine diseases.

Authors:  Jie Li; Liujun Zhao; Wangmi Liu; Weihu Ma; Rongming Xu; Wei-Yu Jiang; Yongjie Gu; Liangjie Lu; Liang Yu; Feng Qi
Journal:  Eur Spine J       Date:  2015-02-20       Impact factor: 3.134

8.  Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine.

Authors:  Liujun Zhao; Guoqing Li; Jiayong Liu; Gregory M Benedict; Nabil A Ebraheim; Weihu Ma; Shaohua Sun; Rongming Xu; Chaoyue Ruan
Journal:  Eur Spine J       Date:  2014-07-24       Impact factor: 3.134

9.  Hybrid Solutions for the Surgical Treatment of Multilevel Degenerative Cervical Disk Disease.

Authors:  Stefan Alexander König; Sebastian Ranguis; Uwe Spetzger
Journal:  Surg J (N Y)       Date:  2015-11-19

10.  In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).

Authors:  Heiko Koller; Wolfgang Hitzl; Frank Acosta; Mark Tauber; Juliane Zenner; Herbert Resch; Yasutsugu Yukawa; Oliver Meier; Rene Schmidt; Michael Mayer
Journal:  Eur Spine J       Date:  2009-07-03       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.