Literature DB >> 10581504

Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA.

J Svensson1, J S Petersson, F Ståhlberg, E M Larsson, P Leander, L E Olsson.   

Abstract

The purpose of this work was to study image effects due to time-varying contrast medium concentration in contrast-enhanced three dimensional (3D) magnetic resonance angiography (MRA) images. Two different simulation models (1D and 3D) and two different contrast medium variation schemes were used. Phantom measurements were also performed. Experiments were performed for several different bolus timings. Similar sequence and image object parameters were used in both simulations and measurements (TE/TR 2. 1/7.8 mses, flip angle 30 degrees, T1/T2 1200-80/150-40 msec, flow velocity 100 cm/sec). A small variation in bolus timing yielded large variations in the appearance of the image effects, especially if the center of k-space was sampled in the vicinity of rapid contrast medium concentration variation. For a typical bolus injection in a patient, a severe signal loss but only minor ringing and edge artifacts appeared if the bolus injection was poorly timed. Effects of pulsatile flow were minor. The 3D model proved to be a useful tool in these studies. J. Magn. Reson. Imaging 1999;10:919-928. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10581504     DOI: 10.1002/(sici)1522-2586(199912)10:6<919::aid-jmri3>3.0.co;2-w

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

Review 1.  CT and MR imaging diagnosis and staging of hepatocellular carcinoma: part I. Development, growth, and spread: key pathologic and imaging aspects.

Authors:  Jin-Young Choi; Jeong-Min Lee; Claude B Sirlin
Journal:  Radiology       Date:  2014-09       Impact factor: 11.105

2.  Three-dimensional isotropic contrast-enhanced MR angiography of the carotid artery using sensitivity-encoding and random elliptic centric k-space filling: technique optimization.

Authors:  G Riedy; X Golay; E R Melhem
Journal:  Neuroradiology       Date:  2005-07-13       Impact factor: 2.804

Review 3.  Cross-sectional vascular imaging with CT and MR angiography.

Authors:  Hasan K Kabul; Klaus D Hagspiel
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

4.  The impact of the dosage of intravenous gadolinium-chelates on the vascular signal intensity in MR angiography.

Authors:  Johannes T Heverhagen; Isabelle Reitz; Martina Pavlicova; Andrea L Levine; Klaus J Klose; Hans-Joachim Wagner
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

5.  Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution: Gd-EOB-DTPA versus Gd-DTPA in vivo.

Authors:  Yasunari Fujinaga; Hitoshi Ueda; Yoshihiro Kitou; Yoshinori Tsukahara; Yukiko Sugiyama; Masumi Kadoya
Journal:  Jpn J Radiol       Date:  2012-11-20       Impact factor: 2.374

6.  Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase.

Authors:  Yasunari Fujinaga; Ayumi Ohya; Hirokazu Tokoro; Akira Yamada; Kazuhiko Ueda; Hitoshi Ueda; Yoshihiro Kitou; Yasuo Adachi; Aya Shiobara; Naomichi Tamaru; Marcel D Nickel; Katsuya Maruyama; Masumi Kadoya
Journal:  Eur Radiol       Date:  2014-03-15       Impact factor: 5.315

7.  Controlled experimental study depicting moving objects in view-shared time-resolved 3D MRA.

Authors:  Petrice M Mostardi; Clifton R Haider; Phillip J Rossman; Eric A Borisch; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

8.  Imaging considerations for in vivo 13C metabolic mapping using hyperpolarized 13C-pyruvate.

Authors:  Y-F Yen; S J Kohler; A P Chen; J Tropp; R Bok; J Wolber; M J Albers; K A Gram; M L Zierhut; I Park; V Zhang; S Hu; S J Nelson; D B Vigneron; J Kurhanewicz; H A A M Dirven; R E Hurd
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

9.  Towards An Advanced Graphene-Based Magnetic Resonance Imaging Contrast Agent: Sub-acute Toxicity and Efficacy Studies in Small Animals.

Authors:  Shruti Kanakia; Jimmy Toussaint; Dung Minh Hoang; Sayan Mullick Chowdhury; Stephen Lee; Kenneth R Shroyer; William Moore; Youssef Z Wadghiri; Balaji Sitharaman
Journal:  Sci Rep       Date:  2015-12-02       Impact factor: 4.379

10.  TRICKS magnetic resonance angiography at 3-tesla for assessing whole lower extremity vascular tree in patients with high-grade critical limb ischemia: DSA and TASC II guidelines correlations.

Authors:  Sheung-Fat Ko; Jiunn-Jye Sheu; Chen-Chang Lee; Chung-Cheng Huang; Fan-Yen Lee; Shu-Hang Ng; Yi-Wei Lee; Hon-Kan Yip; Min-Chi Chen
Journal:  ScientificWorldJournal       Date:  2012-12-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.