Literature DB >> 16012823

Three-dimensional isotropic contrast-enhanced MR angiography of the carotid artery using sensitivity-encoding and random elliptic centric k-space filling: technique optimization.

G Riedy1, X Golay, E R Melhem.   

Abstract

We present a study that helped optimize a three-dimensional isotropic contrast-enhanced MR angiographic (CE-MRA) technique, using sensitivity encoding (SENSE) and random elliptic centric k-space filling. Two-dimensional gradient-echo sequence (TR/TE/flip angle 3.4/0.97/40 degrees ) was used to generate time-intensity curves in porcine carotid arteries for a fixed dose of Gd-DTPA (0.02 mmol/kg) at the following intravenous injection rates: 0.1, 0.3, 0.5, 1.0, 1.5, 2.0, and 3.0 ml/s. The time of contrast arrival and time to peak were recorded. Based on the time-intensity curves, three-dimensional high-resolution isotropic (1 mm3) CE-MRA sequence (TR/TE/flip angle: 4.9/2.4/30 degrees ), using SENSE (reduction factor of 2) and random elliptic centric k-space filling, was initiated twice for each of the above injection rates: first at the time of contrast arrival and second at the time of peak contrast. The three-dimensional CE-MRA images were analyzed for artifacts, signal-to-noise ratio, and venous contamination. For the three-dimensional CE-MRA acquisitions that were initiated at the time of contrast arrival, there was a gradual improvement in signal-to-noise ratio (SNR) in the carotid arteries with increasing injection rate. The same trend was not observed for the acquisitions that were initiated at the time of peak contrast. SENSE combined with random elliptic k-space acquisition in CE-MRA allows for higher SNR with fewer ringing artifacts at faster contrast injection rates.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16012823     DOI: 10.1007/s00234-005-1416-2

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  8 in total

1.  Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA.

Authors:  J Svensson; J S Petersson; F Ståhlberg; E M Larsson; P Leander; L E Olsson
Journal:  J Magn Reson Imaging       Date:  1999-12       Impact factor: 4.813

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Contrast-enhanced 3D MRA using SENSE.

Authors:  M Weiger; K P Pruessmann; A Kassner; G Roditi; T Lawton; A Reid; P Boesiger
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

4.  Optimal dose of Gd-DTPA in dynamic MR studies.

Authors:  H Rusinek; V S Lee; G Johnson
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

5.  Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE).

Authors:  X Golay; S J Brown; R Itoh; E R Melhem
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

6.  Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience.

Authors:  Winfried A Willinek; Jürgen Gieseke; Rudolf Conrad; Holger Strunk; Romhild Hoogeveen; Marcus von Falkenhausen; Ewald Keller; Horst Urbach; Christiane K Kuhl; Hans H Schild
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

7.  Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging.

Authors:  A H Wilman; S J Riederer
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

8.  The effect of injection rate on time-resolved contrast-enhanced peripheral MRA.

Authors:  T J Carroll; F R Korosec; J S Swan; T F Hany; T M Grist; C A Mistretta
Journal:  J Magn Reson Imaging       Date:  2001-10       Impact factor: 4.813

  8 in total
  5 in total

1.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

2.  MRI of degenerative lumbar spine disease: comparison of non-accelerated and parallel imaging.

Authors:  Ingo Nölte; Lars Gerigk; Marc A Brockmann; André Kemmling; Christoph Groden
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

3.  PC HYPR flow: a technique for rapid imaging of contrast dynamics.

Authors:  Julia V Velikina; Kevin M Johnson; Yijing Wu; Alexey A Samsonov; Patrick Turski; Charles A Mistretta
Journal:  J Magn Reson Imaging       Date:  2010-02       Impact factor: 4.813

Review 4.  Multidetector-row CT angiography in the study of atherosclerotic carotid arteries.

Authors:  Luca Saba; Roberto Sanfilippo; Raimondo Pirisi; Luigi Pascalis; Roberto Montisci; Giorgio Mallarini
Journal:  Neuroradiology       Date:  2007-07-03       Impact factor: 2.804

Review 5.  Whole-body magnetic resonance angiography at 3.0 Tesla.

Authors:  Michael Fenchel; Kambiz Nael; Achim Seeger; Ulrich Kramer; Roya Saleh; Stephan Miller
Journal:  Eur Radiol       Date:  2008-02-15       Impact factor: 7.034

  5 in total