Literature DB >> 10580946

Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs.

E Samei1, M J Flynn, W R Eyler.   

Abstract

PURPOSE: To assess the relative influence of quantum mottle and structured lung patterns (anatomic noise) on the detection of subtle lung nodules on chest radiographs.
MATERIALS AND METHODS: Sixty 8 x 8-cm lung pattern images were extracted from digital chest radiographs in healthy individuals. Sixty quantum mottle images of the same size and quantum noise level were extracted from uniformly exposed digital radiographs. Simulated nodules with various peak contrast-diameter products (CD) that emulated subtle tissue-equivalent lung nodules were numerically superimposed at the center on three-fourths of the images. Printouts were independently viewed and scored by five experienced radiologists. The area under the receiver operating characteristic curve (Az) was estimated as a measure of the detectability of the nodules.
RESULTS: At a fixed observer performance level (e.g., Az = 0.8), much smaller and lower-contrast nodules were detected on quantum mottle images (1-mm diameter, CD = 0.01 mm), compared with those on anatomic images (4.5-mm diameter, CD = 0.20 mm). The findings generally agreed with the signal-to-noise ratio calculations based on statistical observer models.
CONCLUSION: The detection of subtle lung nodules on chest radiographs is limited by anatomic noise.

Mesh:

Year:  1999        PMID: 10580946     DOI: 10.1148/radiology.213.3.r99dc19727

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  42 in total

1.  A method to produce and validate a digitally reconstructed radiograph-based computer simulation for optimisation of chest radiographs acquired with a computed radiography imaging system.

Authors:  C S Moore; G P Liney; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2011-10       Impact factor: 3.039

2.  Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography.

Authors:  Patrik Sund; Magnus Båth; Susanne Kheddache; Lars Gunnar Månsson
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

3.  A computerized scheme for lung nodule detection in multiprojection chest radiography.

Authors:  Wei Guo; Qiang Li; Sarah J Boyce; H Page McAdams; Junji Shiraishi; Kunio Doi; Ehsan Samei
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  Preliminary evaluation of biplane correlation (BCI) stereographic imaging for lung nodule detection.

Authors:  Sarah J Boyce; H Page McAdams; Carl E Ravin; Edward F Patz; Lacey Washington; Santiago Martinez; Lynne Koweek; Ehsan Samei
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

5.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

6.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

7.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

8.  Dose dependence of mass and microcalcification detection in digital mammography: free response human observer studies.

Authors:  Mark Ruschin; Pontus Timberg; Magnus Båth; Bengt Hemdal; Tony Svahn; Rob S Saunders; Ehsan Samei; Ingvar Andersson; Soren Mattsson; Dev P Chakrabort; Anders Tingber
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

9.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis.

Authors:  Devon J Godfrey; H Page McAdams; James T Dobbins
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  An alternate method for using a visual discrimination model (VDM) to optimize soft-copy display image quality.

Authors:  Dev P Chakraborty
Journal:  J Soc Inf Disp       Date:  2006-10       Impact factor: 2.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.