Literature DB >> 10551064

The implant neck: smooth or provided with retention elements. A biomechanical approach.

S Hansson1.   

Abstract

A combined three-dimensional and axisymmetric finite element analysis was made of the effect upon the peak interfacial shear stress of providing an axially loaded mandibular dental implant with retention elements all the way up to the crest of the implant as opposed to a smooth neck. The effect of increased wall thickness of the implant and of using bi-cortical fixation as opposed to uni-cortical fixation was also studied. Retention elements at the implant neck were found to bring about a major decrease in the peak interfacial shear stress. Increased wall thickness and bi-cortical fixation also resulted in decreased peak interfacial shear stress but this effect was minor. The interpretation of this was that all these three measures increase the capacity of the implant to carry axial loads. Thus from a biomechanical viewpoint it appears to be advantageous to provide the neck of screw-shaped implants with retention elements, for example a rough surface of suitable micro-architecture and/or a micro-thread. It is furthermore suggested that retention elements at the implant neck will counteract marginal bone resorption in accordance with Wolff's law. This paper is a revision of: Hansson, S. (1997) Some steps to improve the capacity of dental implants to resist axial loads. In: Hansson, S., ed. Towards an optimized dental implant and implant bridge design: A biomechanical approach. Thesis. Göteborg: Chalmers University of Technology.

Mesh:

Substances:

Year:  1999        PMID: 10551064     DOI: 10.1034/j.1600-0501.1999.100506.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  26 in total

Review 1.  Surface treatments and roughness properties of Ti-based biomaterials.

Authors:  Andrea Bagno; Carlo Di Bello
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

3.  Influence of platform switching on bone-level alterations: a three-year randomized clinical trial.

Authors:  N Enkling; P Jöhren; J Katsoulis; S Bayer; P-M Jervøe-Storm; R Mericske-Stern; S Jepsen
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

4.  A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants.

Authors:  Hee-Jung Yun; Jung-Chul Park; Jeong-Ho Yun; Ui-Won Jung; Chang-Sung Kim; Seong-Ho Choi; Kyoo-Sung Cho
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

5.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

6.  Use of polyelectrolyte thin films to modulate osteoblast response to microstructured titanium surfaces.

Authors:  Jung Hwa Park; Rene Olivares-Navarrete; Christine E Wasilewski; Barbara D Boyan; Rina Tannenbaum; Zvi Schwartz
Journal:  Biomaterials       Date:  2012-04-27       Impact factor: 12.479

7.  Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year.

Authors:  Min-Jung Kwon; In-Sung Yeo; Young-Kyun Kim; Yang-Jin Yi; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-06-30       Impact factor: 1.904

Review 8.  Surface modification of biomedical and dental implants and the processes of inflammation, wound healing and bone formation.

Authors:  Clark M Stanford
Journal:  Int J Mol Sci       Date:  2010-01-25       Impact factor: 5.923

9.  Alveolar ridge resorption after tooth extraction: A consequence of a fundamental principle of bone physiology.

Authors:  Stig Hansson; Anders Halldin
Journal:  J Dent Biomech       Date:  2012-08-16

10.  Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

Authors:  Mansour Rismanchian; Bijan Movahedian; Navid Khalighinejad; Hamid Badrian; Sayed Mohammad Razavi; Afsaneh Nekouie
Journal:  ISRN Dent       Date:  2012-07-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.